Portable Diode Laser 980nm Vascular Removal Machine
$0.00
Shipped From Abroad
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Vascular Removal Machine
Red blood streaks are caused by the thinning of the stratum corneum on the face, which causes the capillaries to expand due to the influence of the external environment. The light emitted by the vascular removal machine passes through the epidermis and enters the dermis layer of the abnormally expanded blood vessel network. The hemoglobin in the capillaries in the lesion area is heated and coagulated, closing the abnormally expanded blood vessels, thereby achieving the effect of removing red blood filaments. Skin discoloration is clean, neat, and beautiful.
980nm Laser Functions:
- Collagen production, improves skin elasticity and increases skin thickness and density
- Repairs capillaries, restore their elasticity, and improves skin redness and heat caused by red blood filaments
- Whitening
- Rejuvenating
- Removing freckles
- A comprehensive cosmetic effect. Moreover, there is no trauma after treatment, and you can leave after the treatment
5 Spot Size
The 5 different sizes, the focus is different, which means the size of the light spot.
For example, 3mm, that is the diameter of the light spot is 3mm, which is suitable for each red blood filament that is thicker. On the contrary, if the diameter of each red blood filament of your customer is relatively small and thin, then you can choose 0.2mm or 0.5mm. For each relatively thick red blood filament, using 3mm can quickly complete the treatment and reduce the customer’s pain.
For each relatively thin red blood filament, using 0,2mm can make the treatment more convenient. Choose the appropriate diameter of the treatment head according to the diameter of the red blood filament, which is more efficient.
980NM Laser Specifications
Specification | 980nm Laser | |||
Power supply | 30W | |||
Wavelength | 980nm | |||
Type | Diode Laser | |||
Spot Size | 0.2mm/0.5mm/1mm/2mm/3mm | |||
Frequency | 1-10Hz | |||
Operation | 10.4TFT True Color Touch Screen | |||
Electrical input | 90-130V, 50/60HZ or 200-260V, 50HZ |
Quick Comparison
Settings | Portable Diode Laser 980nm Vascular Removal Machine remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | Portable Medical 365nm Woods Lamp for Skin Analysis remove | Lab/Ward Coat remove | Intense Pulsed Light Therapy Device M40e+ remove | Electric Dermatome remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Portable Diode Laser 980nm Vascular Removal Machine remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | Portable Medical 365nm Woods Lamp for Skin Analysis remove | Lab/Ward Coat remove | Intense Pulsed Light Therapy Device M40e+ remove | Electric Dermatome remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130105-32 | SF1033560096-4 | SF10335601217 | SF1033560084-222 | SF1033560130100-5 | SF10335601214 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
| $11.00 |
| $6,507.00 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
| Shipped From Abroad
The Wood's lamp test is done to help to detect several conditions affecting the skin, including:Bacterial infections, Fungal infections, Ectoparasites infestations, Skin coloring changes. Some skin diseases such as vitiligo, acne and host of other cause the skin to fluoresce Vitiligo, Bacterial Infections, excema, Porphyria, Erythasma, Alopecia, Tinea Versicolor Fungus &Fungal Infections, Head Lice and their nits, Fluoresce under black light Ringworm, Scabies, Child abuse/bruising can often be discerned with the wood's lamp.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
|
Shipped From Abroad
Operating range: The intense pulsed light therapy device HONKON-M40e+ is suitable for the operation of capillary dilation and superficial pigmentation: improvement of photoaged skin.Technical Parameters: Gear model: F+E F+E+ Rated input power (w): 800 Overall dimensions (mm) 600*500*510 Weight (Kg): 30Accessories Details: The equipment consists of operating tools and filters, power supply and control device, protection system, cooling system (internal circulation water cooling, fan). Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness
adjusting button is unilateral adjustment, with high stability and no need
calibrate to zero.
2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.
Note: Special size width plate can be customized according to requirements.
3. The blade has self-lubricating function and is easy to load and unload. It can move
back and forth smoothly to prevent metal to metal collision.
4. Original imported motor, low inertia electric motor will hardly produce any
vibration when rotating, rotate speed: 4500-5000rpm.
5. Hand held control, easy to operate; handle with contact switch design, safety to use
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Vascular Removal MachineRed blood streaks are caused by the thinning of the stratum corneum on the face, which causes the capillaries to expand due to the influence of the external environment. The light emitted by the vascular removal machine passes through the epidermis and enters the dermis layer of the abnormally expanded blood vessel network. The hemoglobin in the capillaries in the lesion area is heated and coagulated, closing the abnormally expanded blood vessels, thereby achieving the effect of removing red blood filaments. Skin discoloration is clean, neat, and beautiful. 980nm Laser Functions:
980NM Laser Specifications
| CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever.
Features:
| Portable Medical 365nm Woods Lamp for Skin AnalysisThe Wood's lamp test is done to help to detect several conditions affecting the skin, including: Bacterial infections, Fungal infections, Ectoparasites infestations, Skin coloring changes. Some skin diseases such as vitiligo, acne and host of other cause the skin to fluoresce Vitiligo, Bacterial Infections, eczema, Porphyria, Erythasma, Alopecia, Tinea Versicolor Fungus &Fungal Infections, Head Lice and their nits, fluoresce under black light Ringworm, Scabies, Child abuse/bruising can often be discerned with the wood's lamp. 1. Pigment abnormal skin disease 2. Infectious skin disease 3. erythroderma desquamativum 4. Neuropsychiatric disorders 5. Some metabolic skin diseases 6. diagnosis and definition of scope of skin lesions of certain tinea corporis and cruris,marla folliculitis disease 7. Certain metabolic skin disease Features: a. Observation Window+Shade Cloth, User can observe and take photos clearly in normal environment b. Rechargeable Lithium Battery, getting rid of the power cord, more convenient to carry and use, more suitable for home use c. UVA Light+White Light (LED), Low power consumption, long life. It is not only used for the examination of various skin diseases, but also can be used for other medical examination illumination. d. Eye-protecting Glass to avoid UV radiation on the human eye damage e. Adjustable Brightness f. Mobile Phone holder (Optional) Technical Specification:
|
| Scope of application: HONKON-M40e+ Intense Pulsed Light Therapy Device is suitable for the treatment of telangiectasia and superficial pigmentation, and improvement of photo-aged skin. | Electric DermatomeTechnical Parameters: 1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm. Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use. 6. Exclusive design of pulled and plugged handle connection line, easy to use. (the length of handle connection line is greater than 3m) 7. Power supply: 220V±10% AC automatic switching, 150/60Hz single phase. Output 14.5V DC, 4.3A. 8. Degree of prevention of liquid entry: IPXO. 9. Sterilization Method: Sterilization Mode: pre-vacuum and gravity displacement steam sterilization or low temperature plasma sterilization can be conducted in whole machine and power cord. And the power cord can be pulled and plugged. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.