Portable Diode Laser 980nm Vascular Removal Machine

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130105-32
Brands:: Stellelaser

Description

Vascular Removal Machine

vascular removal machine

Red blood streaks are caused by the thinning of the stratum corneum on the face, which causes the capillaries to expand due to the influence of the external environment. The light emitted by the vascular removal machine passes through the epidermis and enters the dermis layer of the abnormally expanded blood vessel network. The hemoglobin in the capillaries in the lesion area is heated and coagulated, closing the abnormally expanded blood vessels, thereby achieving the effect of removing red blood filaments. Skin discoloration is clean, neat, and beautiful.

removal red blood

980nm Laser Functions:
  • Collagen production, improves skin elasticity and increases skin thickness and density
  • Repairs capillaries, restore their elasticity, and improves skin redness and heat caused by red blood filaments
  • Whitening
  • Rejuvenating
  • Removing freckles
  • A comprehensive cosmetic effect. Moreover, there is no trauma after treatment, and you can leave after the treatment

5 Spot Size

980nm 5 spot size

The 5 different sizes,  the focus is different, which means the size of the light spot.

For example, 3mm, that is the diameter of the light spot is 3mm, which is suitable for each red blood filament that is thicker. On the contrary, if the diameter of each red blood filament of your customer is relatively small and thin, then you can choose 0.2mm or 0.5mm. For each relatively thick red blood filament, using 3mm can quickly complete the treatment and reduce the customer’s pain.

For each relatively thin red blood filament, using 0,2mm can make the treatment more convenient. Choose the appropriate diameter of the treatment head according to the diameter of the red blood filament, which is more efficient.

980NM Laser Specifications
Specification 980nm Laser
Power supply 30W
Wavelength 980nm
Type Diode Laser
Spot Size 0.2mm/0.5mm/1mm/2mm/3mm
Frequency 1-10Hz
Operation 10.4TFT True Color Touch Screen
Electrical input 90-130V, 50/60HZ or 200-260V, 50HZ

 

Reviews

There are no reviews yet.

Be the first to review “Portable Diode Laser 980nm Vascular Removal Machine”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPortable Diode Laser 980nm Vascular Removal Machine removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removePortable Medical 365nm Woods Lamp for Skin Analysis removeLab/Ward Coat removeIntense Pulsed Light Therapy Device M40e+ removeElectric Dermatome remove
NamePortable Diode Laser 980nm Vascular Removal Machine removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removePortable Medical 365nm Woods Lamp for Skin Analysis removeLab/Ward Coat removeIntense Pulsed Light Therapy Device M40e+ removeElectric Dermatome remove
Image
SKUSF1033560130105-32SF1033560096-4SF10335601217SF1033560084-222SF1033560130100-5SF10335601214
Rating
Price

$0.00

$0.00

$0.00

$11.00

$0.00

$6,507.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The Wood's lamp test is done to help to detect several conditions affecting the skin, including:Bacterial infections, Fungal infections, Ectoparasites infestations, Skin coloring changes. Some skin diseases  such as vitiligo, acne and host of other cause the skin to fluoresce Vitiligo, Bacterial Infections, excema, Porphyria, Erythasma, Alopecia, Tinea Versicolor Fungus &Fungal Infections, Head Lice and their nits, Fluoresce under black light Ringworm, Scabies, Child abuse/bruising can often be discerned with the wood's lamp. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

Operating range:

The intense pulsed light therapy device HONKON-M40e+ is suitable for the operation of capillary dilation and superficial pigmentation: improvement of photoaged skin.

Technical Parameters:

Gear model: F+E F+E+ Rated input power (w): 800 Overall dimensions (mm) 600*500*510 Weight (Kg): 30

Accessories Details:

The equipment consists of operating tools and filters, power supply and control device, protection system, cooling system (internal circulation water cooling, fan). Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.   Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Vascular Removal Machine

vascular removal machine

Red blood streaks are caused by the thinning of the stratum corneum on the face, which causes the capillaries to expand due to the influence of the external environment. The light emitted by the vascular removal machine passes through the epidermis and enters the dermis layer of the abnormally expanded blood vessel network. The hemoglobin in the capillaries in the lesion area is heated and coagulated, closing the abnormally expanded blood vessels, thereby achieving the effect of removing red blood filaments. Skin discoloration is clean, neat, and beautiful.

removal red blood

980nm Laser Functions:
  • Collagen production, improves skin elasticity and increases skin thickness and density
  • Repairs capillaries, restore their elasticity, and improves skin redness and heat caused by red blood filaments
  • Whitening
  • Rejuvenating
  • Removing freckles
  • A comprehensive cosmetic effect. Moreover, there is no trauma after treatment, and you can leave after the treatment
5 Spot Size

980nm 5 spot size

The 5 different sizes,  the focus is different, which means the size of the light spot. For example, 3mm, that is the diameter of the light spot is 3mm, which is suitable for each red blood filament that is thicker. On the contrary, if the diameter of each red blood filament of your customer is relatively small and thin, then you can choose 0.2mm or 0.5mm. For each relatively thick red blood filament, using 3mm can quickly complete the treatment and reduce the customer’s pain. For each relatively thin red blood filament, using 0,2mm can make the treatment more convenient. Choose the appropriate diameter of the treatment head according to the diameter of the red blood filament, which is more efficient.
980NM Laser Specifications
Specification 980nm Laser
Power supply 30W
Wavelength 980nm
Type Diode Laser
Spot Size 0.2mm/0.5mm/1mm/2mm/3mm
Frequency 1-10Hz
Operation 10.4TFT True Color Touch Screen
Electrical input 90-130V, 50/60HZ or 200-260V, 50HZ
 
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  
Portable Medical 365nm Woods Lamp for Skin Analysis
The Wood's lamp test is done to help to detect several conditions affecting the skin, including: Bacterial infections, Fungal infections, Ectoparasites infestations, Skin coloring changes. Some skin diseases such as vitiligo, acne and host of other cause the skin to fluoresce Vitiligo, Bacterial Infections, eczema, Porphyria, Erythasma, Alopecia, Tinea Versicolor Fungus &Fungal Infections, Head Lice and their nits, fluoresce under black light Ringworm, Scabies, Child abuse/bruising can often be discerned with the wood's lamp. 1. Pigment abnormal skin disease 2. Infectious skin disease 3. erythroderma desquamativum 4. Neuropsychiatric disorders 5. Some metabolic skin diseases 6. diagnosis and definition of scope of skin lesions of certain tinea corporis and cruris,marla folliculitis disease 7. Certain metabolic skin disease Features: a. Observation Window+Shade Cloth, User can observe and take photos clearly in normal environment b. Rechargeable Lithium Battery, getting rid of the power cord, more convenient to carry and use, more suitable for home use c. UVA Light+White Light (LED), Low power consumption, long life. It is not only used for the examination of various skin diseases, but also can be used for other medical examination illumination. d. Eye-protecting Glass to avoid UV radiation on the human eye damage e. Adjustable Brightness f. Mobile Phone holder (Optional) Technical Specification:
Power Supply Mode Inside power
Power adapter
Battery Specification
Battery standby time
Charging period
Security Classification typeII,built-in battery
Power Rating 28VA
Visual Lens Diameter ø65mm±5mm
Working Distance 5cm±1cm
Light Source UVA light+White light
Output Wavelength 320nm-400nm  (Peak wavelength365nm)
Lamp Life ≥15000h
UV radiation intensity 0.6-2.5mW/cm2 
Illuminance ≥1200Lux
Visual lens magnification times 2times±20%
Dustproof and waterproof level IP22
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Scope of application: HONKON-M40e+ Intense Pulsed Light Therapy Device is suitable for the treatment of telangiectasia and superficial pigmentation, and improvement of photo-aged skin.
Electric Dermatome
Technical Parameters: 1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.   Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use. 6. Exclusive design of pulled and plugged handle connection line, easy to use. (the length of handle connection line is greater than 3m) 7. Power supply: 220V±10% AC automatic switching, 150/60Hz single phase. Output 14.5V DC, 4.3A. 8. Degree of prevention of liquid entry: IPXO. 9. Sterilization Method: Sterilization Mode: pre-vacuum and gravity displacement steam sterilization or low temperature plasma sterilization can be conducted in whole machine and power cord. And the power cord can be pulled and plugged.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare