3 Phase Low Frequency Online UPS LF33 Series

$0.00

Shipped From Abroad

Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-4
Brands:: Reeco Power

Description

Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input

 

Specifications
MODEL LF33 10K LF33 20K LF33 30K LF33 40K LF33  60K LF33  80K LF33 100K LF33 120K LF33 160K LF33 200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hzor56-64Hz
INVERTER
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement 120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time Restore to 90% of rated value in 3 cycles
Overload capacity 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load                    <1%
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840x432x1140 975x554x1286 1200x910x1680 1500x1140x1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350

Reviews

There are no reviews yet.

Be the first to review “3 Phase Low Frequency Online UPS LF33 Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

Settings3 Phase Low Frequency Online UPS LF33 Series removeSingle Phase High Frequency Online UPS VT Series 6KVA-20KVA removeOPzV Tubular Gel Battery 60AH-3000AH removePortable Power Station PS Series 2200W removePortable Power Station PX Series 500W removeHigh Frequency Modular UPS VM Series remove
Name3 Phase Low Frequency Online UPS LF33 Series removeSingle Phase High Frequency Online UPS VT Series 6KVA-20KVA removeOPzV Tubular Gel Battery 60AH-3000AH removePortable Power Station PS Series 2200W removePortable Power Station PX Series 500W removeHigh Frequency Modular UPS VM Series remove
Image
SKUSF1033560130139-4SF1033560130139-26SF1033560130139-18SF1033560130139-22SF1033560130139-24SF1033560130139-11
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
 
Specifications
MODEL LF33 10K LF33 20K LF33 30K LF33 40K LF33  60K LF33  80K LF33 100K LF33 120K LF33 160K LF33 200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hzor56-64Hz
INVERTER
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement 120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time Restore to 90% of rated value in 3 cycles
Overload capacity 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load                    <1%
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840x432x1140 975x554x1286 1200x910x1680 1500x1140x1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT6K VT6KL VT10K VT10KL 31VT10KL 31VT15KL 31VT20KL
Capacity 6KVA/5400W 10KVA/9000W 15KVA/13.5KW 20KVA/18KW
Input Nominal Voltage 220/230/240Vac 380/400/415Vac
Voltage Range 120-275VAC(1P2W+G) 207-475VAC(3P4W+G)
Current 31A (max) 50A(max) 50A (max) 75A(max) 100A(max)
Frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Power Factor ≥0.99·
Output Voltage 220/230/240±2%Vac (1P2W+G)
Frequency 50/60 Hz(adjustable) 50/60Hz± 5% (Line mode) 50/60Hz ± 0.05Hz ( Battery mode)
Current 27.3A 45A 68A 91A
Power Factor 0.9
Waveform Pure Sine Wave
Waveform Distortion Line load <2% Line load <3%
Back-up Time Full Load ≥7′ Depends on external batteries bank’s Capacity ≥5′ Depends on external batteries bank’s Capacity
Half Load ≥20 ≥13′
Battery Nominal Voltage 192/240Vdc
Transfer Time 0ms
Overload Capacity 105%±5%< Load<125%±5% :1 min transfer to bypass 125% ±5% < Load<135 % ±5 % :30s transfer to bypass Load > 135 % ± 5 %: 300s transfer to bypass
Communication SNMP,RS-232,USB+lntelligent Slot
Operating Environment Temperature 0°C~40°C
Humidity 15%~90%
Dimension Width (mm) 260 260 260 260 260
Depth (mm) 560 533 560 533 560
Height (mm) 717 501 717 501 717
Net Weight(Kg) 55 12.2 62 21 23 32 33
Features:
  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation, OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere, even in remote environments with minimal supervision.

 
Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8) F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Rated Power: 500W
  • Rated Capacity: 519 . 48wh
  • Standard Capacity: 3.7V/140400mah
  • Overload Protecion: 550W + 40W
  • AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
  • Output Wave: Pure sine wave
  • USB Output: QC 18W*2
  • Type-c Output: PD 60W*2
  • Cigarret Lighter Output: 14V/8A
  • DC5525 Output: 14V/8A
  • Wireless Charging: 15W
  • Charging Input: 12-26 V/100W Max
  • WorkingTemperature: -10-40 °C
  • Weight(Net Weight): 6.8kg
  • Weight(With Accessories): 8.5kg
  • Dimension: 345*227*203mm
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
Digital Control All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance. Intelligent Battery Management Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset ±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional) High Power Density Modular Design The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time. N+x Parallel Redundancy The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%, MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets. A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel. Touchable LCD Display Screen Super large LCD display with touching function. Standard Cabinet Design The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.

Safe and Easy to Maintain When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance; Press EPO button to shutdown in emergentsituation, and also have REPO function. Intelligent Management Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.

 
Technical Specifications
Model VM 90K VM150K VM300K
Capacity UPS Cabinet 30-90KVA 30-150KVA 30-300KVA
Power Module 30kVA
INPUT Input Form 3P4W+G
Rated Voltage 380/400/415Vac
Voltage Range 207~478Vac
Frequency Range 40~70Hz
Input Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%s +15%、+20%) 400 upper limit: 20% (optional +10%、+15%) 415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%) Bypass frequency protection range: ± 10%
Input Current Harmonic Wave ≤3% (100% non-linear)
OUTPUT Output Form 3P4W+G
Rated Voltage 380/400/415Vac
Output Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency Mains Mode Synchronization with input; when mains frequency exceeds maximum value ±10% (can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz
Battery Mode (50/60±0.2%) Hz
Crest Factor 3:1
Conversion Time Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms
Overload Capacity Load≤110%: 60 mins; Load≤125%: 10 mins; Load≤150%: 1 min; Load≥150%, shutdown immediately
Output Voltage Harmonic Wave ≤2% (100% linear)
Efficiency In normal mode 95%
Communication Port RS232、RS485、 Intelligent Slot*2 、 Dry connect port
BATTERY Battery Voltage ±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional)
Charging Current UPS Cabinet 30A Max 50A Max 100A Max
Power Module 10A Max
Environment Operating Temperature 0〜40°C
Relative Humidity 0-95% (non-condensing)
Storage Temperature -25-55°C (excluded battery)
Altitude < 1500m (derating if exceeding 1500m)
Physical Characteristic Outer Dimension (LxWxH) mm Cabinet 840X600X1400 1100X600X2000
Module 580 X 443 X 131
Weight (Net Weight) KG Cabinet 158 170 305
Module 33.5
Operative Standard YD/T 2165-2010
WeightN/AN/AN/AN/AN/AN/A