3 Phase Low Frequency Online UPS LD31 Series

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-2
Brands:: Reeco Power

Description

Description

HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY

IGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.

SIMPLE TO INSTALL

Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer

MAXIMUM BATTERY CARE

Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.

OTHER CHARACTERISTICS

0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.

MAXIMUM RELIABILITY AND AVAILABILITY

Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)

LOW CONSUMPTION LEVELS

LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.

ADVANCE COMMUNICATION:

RS485/RS232/Dry Contact/SNMP(Optional)

 

Specifications
Model 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA    80KVA 100KVA
Capacity 8KW 12 KW 16 KW 24 KW 32 KW 48 KW    64 KW    80 KW
INPUT
Rated voltage 380/400/415 VAC  Three-phase
Voltage range ±20%
Frequency range 45-65Hz
Power factor >0.92 with harmonic filter
Current harmonic distortion <5% with harmonic filter
Soft Start 0 -100% in 10″
BYPASS INPUT
Rated voltage 230VAC   Single Phase
Permitted voltage range ±15%  (selectable from ±10% to ±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%    (selectable from ±1% to ±5% from front panel)
Standard features Back Feed portection; split bypass line
BATTERY
Type VRLA AGM / GEL;NICd
Battery Voltage 384VDC
Maximum recharge current(A) 0.2 X C10
AC ripple voltage <1%
INVERTER OUTPUT
Rated power(kVA) 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Active power(kW)  8KW 12 KW 16 KW 24 KW 32 KW 48 KW     64 KW 80 KW
Number of phases 1
Rated voltage(V) 230VAC  Single Phase
Regulation of the output voltage 220 ~ 244VAC  phase/neutral (from control panel)
Crest factor(Ipeak/Irms) 3:1
Static stability ±1%
Dynamic stability ±5%
Frequency 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10’/1′
Frequency stability ±0.05% on mains failure
System 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Remote signaling Volt free contacts
Remote controls EPO and Bypass
Communication RS232 + Romote Contacts
Operation temperature 0℃ to  ~ 40℃
Relative humidity <95% non condensing
Colour Light grey ( RAL 7035)
Noise 54dBA at 1m 60dBA at 1m   65dBA at 1m
Protection degree IP20
Efficiency Smart Mode Up to 98%
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
Weight(KG)N.W 176 220 205 213 295 440 520 770
Dimensions:(WxDxH)mm 555*730*1210 800*730*1400 1115*730*1400
Internal batteries optional optional optional No      No No No No

Reviews

There are no reviews yet.

Be the first to review “3 Phase Low Frequency Online UPS LD31 Series”

Your email address will not be published. Required fields are marked *

Quick Comparison

Settings3 Phase Low Frequency Online UPS LD31 Series removeSingle Phase High Frequency Online UPS VT Series 6KVA-20KVA removePortable Power Station PS Series 2200W removePortable Power Generator PS Series 1200W removeLead Acid Maintenance Free Battery 5AH-250AH removeLine Interactive UPS AP Series 1000VA-3000VA remove
Name3 Phase Low Frequency Online UPS LD31 Series removeSingle Phase High Frequency Online UPS VT Series 6KVA-20KVA removePortable Power Station PS Series 2200W removePortable Power Generator PS Series 1200W removeLead Acid Maintenance Free Battery 5AH-250AH removeLine Interactive UPS AP Series 1000VA-3000VA remove
Image
SKUSF1033560130139-2SF1033560130139-26SF1033560130139-22SF1033560130139-19SF1033560130139-15SF1033560130139-16
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f
Shipped From Abroad
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA    80KVA 100KVA
Capacity 8KW 12 KW 16 KW 24 KW 32 KW 48 KW    64 KW    80 KW
INPUT
Rated voltage 380/400/415 VAC  Three-phase
Voltage range ±20%
Frequency range 45-65Hz
Power factor >0.92 with harmonic filter
Current harmonic distortion <5% with harmonic filter
Soft Start 0 -100% in 10″
BYPASS INPUT
Rated voltage 230VAC   Single Phase
Permitted voltage range ±15%  (selectable from ±10% to ±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%    (selectable from ±1% to ±5% from front panel)
Standard features Back Feed portection; split bypass line
BATTERY
Type VRLA AGM / GEL;NICd
Battery Voltage 384VDC
Maximum recharge current(A) 0.2 X C10
AC ripple voltage <1%
INVERTER OUTPUT
Rated power(kVA) 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Active power(kW)  8KW 12 KW 16 KW 24 KW 32 KW 48 KW     64 KW 80 KW
Number of phases 1
Rated voltage(V) 230VAC  Single Phase
Regulation of the output voltage 220 ~ 244VAC  phase/neutral (from control panel)
Crest factor(Ipeak/Irms) 3:1
Static stability ±1%
Dynamic stability ±5%
Frequency 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10’/1′
Frequency stability ±0.05% on mains failure
System 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Remote signaling Volt free contacts
Remote controls EPO and Bypass
Communication RS232 + Romote Contacts
Operation temperature 0℃ to  ~ 40℃
Relative humidity <95% non condensing
Colour Light grey ( RAL 7035)
Noise 54dBA at 1m 60dBA at 1m   65dBA at 1m
Protection degree IP20
Efficiency Smart Mode Up to 98%
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
Weight(KG)N.W 176 220 205 213 295 440 520 770
Dimensions:(WxDxH)mm 555*730*1210 800*730*1400 1115*730*1400
Internal batteries optional optional optional No      No No No No
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three Level inverter control technology
  • Large screen LCD display
  • N+X Parallel Redundancy function (3 units parallel)
  • EPO emergency stop function
  • Smart expansion Slots (optional)
  • Support Generator
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT6K VT6KL VT10K VT10KL 31VT10KL 31VT15KL 31VT20KL
Capacity 6KVA/5400W 10KVA/9000W 15KVA/13.5KW 20KVA/18KW
Input Nominal Voltage 220/230/240Vac 380/400/415Vac
Voltage Range 120-275VAC(1P2W+G) 207-475VAC(3P4W+G)
Current 31A (max) 50A(max) 50A (max) 75A(max) 100A(max)
Frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Power Factor ≥0.99·
Output Voltage 220/230/240±2%Vac (1P2W+G)
Frequency 50/60 Hz(adjustable) 50/60Hz± 5% (Line mode) 50/60Hz ± 0.05Hz ( Battery mode)
Current 27.3A 45A 68A 91A
Power Factor 0.9
Waveform Pure Sine Wave
Waveform Distortion Line load <2% Line load <3%
Back-up Time Full Load ≥7′ Depends on external batteries bank’s Capacity ≥5′ Depends on external batteries bank’s Capacity
Half Load ≥20 ≥13′
Battery Nominal Voltage 192/240Vdc
Transfer Time 0ms
Overload Capacity 105%±5%< Load<125%±5% :1 min transfer to bypass 125% ±5% < Load<135 % ±5 % :30s transfer to bypass Load > 135 % ± 5 %: 300s transfer to bypass
Communication SNMP,RS-232,USB+lntelligent Slot
Operating Environment Temperature 0°C~40°C
Humidity 15%~90%
Dimension Width (mm) 260 260 260 260 260
Depth (mm) 560 533 560 533 560
Height (mm) 717 501 717 501 717
Net Weight(Kg) 55 12.2 62 21 23 32 33
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • Capacity: 1200W 1008Wh /315000mAh
  • Input AC Output Power:Rated Power 1200W Peak Power 2400W
  • Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC12V~60V/10A 400W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
Nomimal voltage: 12V Rated Capacity: 5Ah ~ 250Ah Operating temperature range: -15 ~ 45 ℃ The design life is 5 years Using new special process sheet formula to improve the utilization of active material Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and anti-vibration and so on Small internal impedance, excellent performance when high current discharge Low self-discharge, wide operating temperature range Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable Using strict production process, unit voltage balance is strong Free maintenance, without adding water rehydration  
Technical Specifications
Model Nominal Voltage Capacity Dimension LXWXH (mm) Total Height (mm) Weight (KG) Terminal
VL12-24 12 24 166 175 125 125 8 M6
VL12-28 12 28 166 175 125 125 9 M6
VL12-33 12 33 196 130 163 180 10 M6
VL12-35 12 35 197 130 163 180 10.5 M6
VL12-40 12 40 197 166 171 171 13.5 M6
VL12-44 12 44 196 166 171 171 13.5 M6
VL12-55 12 55 230 138 211 229 17.2 M6
VL12-65 12 65 350 166 179 179 22 M6
VL12-70 12 70 260 169 211 229 23 M8
VL12-80 12 80 260 169 211 229 24 M8
VL12-90 12 90 307 169 211 234 28 M8
VL12-100 12 100 331 173 213 233 32 M8
VL12-120 12 120 407 174 209 233 3, 8 M8
VL12-130 12 134 341 173 283 287 41 M8
VL12-150 12 150 484 171 241 241 46 M8
VL12-160 12 160 534 209 216 237 52 M8
VL12-180 12 180 530 209 216 237 56 M8
VL12-200 12 200 522 240 220 244 64 M8
VL12-230 12 230 520 268 220 240 72.5 M8
VL12-250 12 250 520 268 220 249 76 M8
Features:
  • Pure sine wave output
  • DSP digital control
  • Boost and buck AVR for voltage stabilization
  • Cold start function
  • Intelligent battery management
  • Short circuit and overload protection
  • Off-mode charging
  • Offering LED and LCD panels for selection
  • Optional USB/RS232/RJ45/SNMP communication port
 
Technical Specifications
 
MODEL UPS-AP1K ( L ) UPS-AP2K ( L ) UPS-AP3K ( L )
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
INPUT
Voltage range 145~275VAC±5V
Frequency range 50Hz-60Hz
OUTPUT
Output voltage 220VAC
AC voltage range ±10%
Frequency range(batt.mode) 50Hz ± 0.25Hz or 60Hz ± 0.3Hz
Overload 105%-110%: UPS beep alarm, do not shut down.
110%-130%: auto shut down after 30 seconds
> 130%: auto shut down immediately
Transfer time <typical 4ms
Waveform(batt.mode) Pure sine wave
BATTERY
Standard model Battery type 12V7Ah
Numbers 2 4 6
Charging current(Max.) Assume: 1A± 10%; Max: 1A or 2A for option
Charging voltage 27.3VDC±1% 54.7VDC±1% 82.0VDC±1%
Long-run model Battery type 12V, AH depending on applicant
Numbers 3 6 8
Charging current(Max.) > 5A
Charging voltage 27.4VDC±1% 82.1VDC±1% 109.4VDC±1%
PHYSICAL
Standard model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 11.9 22 27.9
Long-run model Dimension, LxWxH(mm) 360x147x220 440x192x340 440x192x340
Net weight(kgs) 8.5 16 18.2
ENVIRONMENT
Humidity 20-90%RH @0-40°C (non-condensing)
Noise level Less than 55dBA@1 Meter
MANAGEMENT
Smart RS-232 Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP Management and web browser
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare