Description | Shipped From Abroad
Baby and toddler scale | ADE M112800
Comfortable to use baby and toddler weighing scale for the checkup of babies’ weight at the GPs office or at home. Quickly convertible to a floor scale with a capacity of 50 kg for toddlers and young children. The last weight memory function will help to calculate the intake of milk by the infant. Perfectly suitable for the rent out service at pharmacies.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
Usage/Application |
Hospital |
Color |
White |
Material |
Plastic |
Application |
Hospital |
Model |
Bilipod |
Brand |
AVI |
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
- Super bright LED optimized for vein viewing
- Superficial veins can be seen and accessed anywhere on the infant's body
- Rechargeable battery
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
- Patented in-house design, elegant appearance
- Steady 12.1 inch monitor, suitable for bedside and transferring
- Simple user-friendly menu, preferable for both regular LCD and touchscreen
- Unique one-key-switching for maximum 7 display interfaces
- Preinstall Plug-and-Play EtCO2 socket, simpler upgrade for ICU application
- Waterproof case in strict accordance with IPX1 on CE regulation
- Wide application for adult, pediatric and neonatal
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
Baby-toddler scale ADE M112800
Description
-
- Unit switch kg/lbs
- Last weight memory function
- Automatic zero setting
- Tare
- Auto hold function
- Low battery indicator
- Auto switch off
- Power supply: Alkaline batteries (2 x AA)
Technical Data
Capacity |
50 kg |
Graduation |
10 g |
Units |
kg, lbs |
Dimensions baby tray |
631 x 320 x 60 mm |
Dimensions weighing platform |
280 x 280 x 29 mm |
Dimensions overall |
631 x 362 x 111 mm |
Weight |
3,1 kg |
| Features:
- BILIPOD LED Double Surface Phototherapy Unit Sturdy Baby Trolley consists of – Collapsible Acrylic Side Panels Transparent Baby Tray with Bubble Mattress Height Adjustment and Angle Adjustment for Overhead LED Module Four Swivelling castor wheels with brakes Certified Also available - Bilipod Double Surface Phototherapy Unit with Detachable trolley
- Uniform Light Distribution with 11 High Intensity LED Lamps uniform body coverage • Observation Lamp Two Observation White LEDs provide enough light to observe the color of baby’s skin • High Irradiance Levels Irradiance > 30 µW/cm²/nm enables faster bilirubin breakdown • Pin Drop Silent Operation zero noise cooling fan • Optimum Wavelength Range: 420 to 490 nm • Very Low Power Consumption of only 30W • Effective Surface Area : 40cm x 50cm
- Life of Lamps - 30000 hours • Lamp Tilt up to 90° • Height Adjustability up to 50cm • Light Weight Lamp Unit weighs less than 3 Kg • Portable can be placed above Infant incubator or below the Infant Warmer Bassinet to give under surface Phototherapy • Sleek & Compact Lamp Unit Size : 45 x 30 x 5 cm takes minimum space • Timer: LCD Based Timer measuring Total Lamp Usage and Patient Timer
- BiliProbe Irradiance Meter Handheld Irradiance (Flux) meter for measurement of the output of conventional Phototherapy Units. Bandpass filter - 425nm to 475nm Range: 0 to 200 uW/cm²/nm Minimal Graduation: 1 uW/cm²/nm Accuracy: ± 10% Measuring Time: Approx 4-5 sec Press to ON Switch Battery: 9V Alkaline Phototherapy Eye PATCH has been designed to assure complete comfort, and eye protection for infants during Phototherapy Treatment Adjustable Band for proper comfort and secure fit Easy to use design Large eye protection pad increases light protection Single Piece wrap around design can be independently adjusted to prevent unwanted movement. Available in 3 sizes - Preterm, Term and Neonatal Phototherapy Eye Patch
Specifications:
Usage/Application |
Hospital |
Color |
White |
Material |
Plastic |
Application |
Hospital |
Model |
Bilipod |
Brand |
AVI |
|
- With bigger bed:
- Servo controlled temperature system by micro-computer;
- Control mode: pre-warm, manual and automatic;
- LED display screen;
- Self-check alarms: power failure,over temperature, temperature deviation, temperature sensor failure;
- APGAR timer to record therapy time;
- With LED phototherapy unit;
- Adjustable bed tilting;
- With illumination light;
- RS-232 connector;
- Heater head can be adjusted ±90°horizontally;
- With transfusion shelf and tray.
- X-ray cassette
Optional accessories:
Suction,Oxygen supply system,Phototherapy unit(Lamp)
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
- Super bright LED optimized for vein viewing
- Superficial veins can be seen and accessed anywhere on the infant's body
- Rechargeable battery
|
Features:
- Patented in-house design, elegant appearance
- Steady 12.1 inch monitor, suitable for bedside and transferring
- Simple user-friendly menu, preferable for both regular LCD and touchscreen
- Unique one-key-switching for maximum 7 display interfaces
- Preinstall Plug-and-Play EtCO2 socket, simpler upgrade for ICU application
- Waterproof case in strict accordance with IPX1 on CE regulation
- Wide application for adult, pediatric and neonatal
Technical Specifications:
Brand Name :PROMISE
Model Number :PRO-M12D
Certification :ISO 13485
Place of Origin :CHINA
Lead Mode :Lead Mode: 5 leads or 3 leads
Lead Selection :I, II, III, avR, avL, avF, V /or I, II, III
Gain :Auto, 2.5, 5, 10, 20mm/mV
HR Range :Adult: 15-300bpm; Ped/Neo: 15-350bpm
HRAccuracy :±1% or ±1bpm
HR Resolution :1bpm
Method :Oscillometric
Range :0-50℃
Respiration :Accuracy: ±2rpm Resolution: 1rpm
Work Mode :Manual,Auto, STAT
NIBP Range :Adult: 10-280mmHg; Ped: 10-220mmHg; Neo: 10-135mmHg
Pulse rate range :40-240bpm
Accuracy :70-100%: ±2%, <70%: unspecified Resolution : 1%
NIBP :Overpressure Protection
SpO2 :Range: 0-100%
PR range :0-250bpm
PRAccuracy :±2bpm PR Resolution: 1bpm
Temperature Channel :2
Temperature :Accuracy: ±0.1℃ Resolution: 0.1℃
Optional :Main/Side stream EtCO2, 2-IBP, 2-TEMP, Recorder, VGAOutput, Touch Screen, CentraMonitoring System, Wall mount, Trolley
Product Dimension :305(L) x 170(W) x 285(H) mm
Package Dimension :430(L) x 390(W) x 310(H) mm
Net Weight :3.2KG
Gross Weight :6.1KG
AC Power Supply :100-240V, 50/60Hz
Built-in battery :2 hours continuous work
|
Reviews
There are no reviews yet.