Description | Shipped From Abroad
JD-2000 Auto Lensmeter delivers fast, precise lens measurements with LCD display, automatic recognition, and user-friendly operation for eye care professionals.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| 83Shipped from abroad
This is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Ship from abroad
- Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
- Durable and easy to operate
- Easily and intuitively read the sphere focal scale value
- High eco-friendly materials
- Design fitting the face curve and no stimulation
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Digital Slit lamp system,Galilean optical system,Five magnifications.
- Independent image process and management software system
- More than 10 million pixel image resolution
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | The JD-2000 Auto Lensmeter is a precise and user-friendly device designed for quick and accurate measurement of optical lenses. It supports single vision, progressive, and contact lens measurements, offering reliability in both clinical and optical shop settings. With its advanced technology, clear LCD display, and fast processing speed, the JD-2000 ensures efficient workflow and dependable results.
Key Features
-
Automatic measurement of single, progressive, and contact lenses
-
High-precision sphere, cylinder, axis, and prism measurements
-
Easy-to-read LCD display for enhanced visibility
-
Fast measurement response for increased efficiency
-
Compact and ergonomic design for convenience
-
Suitable for optical shops, clinics, and laboratories
Technical Specifications
Range of measurement |
Sphere |
0~±25m-1 0.01/0.12/0.25m-1 step |
Cylinder |
0~±9.99m-1 0.01/0.12/0.25m-1 step |
Axis |
0°~180° (1°step) |
Add. |
0~+9.99m-1 0.01/0.12/0.25m-1 step |
Prism degree |
0~15m-1 0.01/0.12/0.25m-1 step |
Measurement mode |
Cylinder |
+,+/-,- |
Prism |
X-Y, P-B |
Contact lens |
Soft/hard lens |
Measuring mode |
Single/progressive/ automatic recognition |
Specifications |
Diameter of lens |
Φ20~Φ108mm |
PD |
40~90mm, 0.5mm step |
Speed of measurement |
0.1second |
Display |
7″LCD/TFT |
Printer |
Thermal printer |
Dimension |
196mm*286mm*442mm |
Weight |
~6kg |
Power supply |
100~240V 50~60Hz |
| Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Features of Applanation Tonometer:
- When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
- Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
- Directly get the ocular pressure and do not need to look up the conversion table.
- The measured ocular pressure is not affected by hardness of eye.
- The affected?ocular volume is just 0.56 cubic millimeter.
- Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
- Measuring Range: 0~1064 Kpa
- Light Ring Displacement: 1.53×2=3.06mm
- Diameter of Prism Head: 7mm
- Moving Range of Prism Head: 3mm
| Portable Fundus Camera is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Features of Portable Fundus Camera:
- Images real-time display, one-button magnifying
- Non-mydriatic and high definition imaging.
- Micro SD memory card up to 32GB for 80,000 images
- USB and WiFi connection
- Low weight 450g, movable and portable
- A rechargeable battery provides up to more than 4 hours of continuous operation.
- Optional imaging modules for examination: posterior ophthalmoscope, anterior segment ophthalmoscope, otoscope, rhinoscope, laryngoscope and dermatoscope
- High definition and stable image
- Easy one-handed operation and excellent portability
- Large data service and a variety of image acquisition mode
Technical Specifications of Portable Fundus Camera:
Model |
MC-600 |
FOV |
45° |
Minimum pupil |
2.5mm |
Refractive compensation |
-20D~+20D |
Light source |
White LED/IR |
Image resolution |
1920×1080 |
Focus Mode |
Manual |
Screen |
3.5" color |
Power |
≤6VA |
Storage |
8GB Micro SD card |
Power supply |
3.7VLithium Battery |
Interface |
Mini USB/Wifi |
N. Weight |
450g(Typical) |
G. Weight |
2.5kg |
Size |
160mm*90mm*190mm |
Packing size |
360mm*310mm*160mm |
| Features:
- Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
- Durable and easy to operate
- Easily and intuitively read the sphere focal scale value
- High eco-friendly materials
- Design fitting the face curve and no stimulation
- Easy to take and clean
- Free switch between the cross-cylindrical lens and the rotary prism
- When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
- It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere |
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1 |
Cylinder |
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1 |
Cylinder Axis |
Range: 0~180°, Step:5° |
Distance of Optical center (also known as Pupil) |
Range: 50~75mmStep: 1mm |
Sight Switch |
Range:∞~380mm (distance of Optical center is64mm) |
Front Chin Test |
Range: 0~16mm |
Distance (from cornea vertex to the lens surface) |
16mm |
Standard Accessories Lens |
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively |
Standard Accessories |
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover |
Auxiliary Lens |
“O”:Open aperture
“R”:Retinoscope lens
“R”:Retinoscope lens
“R”:Retinoscope lens
*Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters
“P”:Polaroid
* it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision
“RMV”:Red Vertical maddox
*Be used to examine Implicit strabismus
“RMH”:Red horizontal maddox
*Be used to examine Implicit strabismus
“WMV”:Plane Vertical Maddox
*Be used to examine Implicit strabismus
“WMH”:Plane horizontal maddox
*Be used to examine Implicit strabismus
“RL”:Red lens
*Be used to examine eye function, Blending function and Implicit strabismus
“GL”:Green lens
*Be used to examine eye function, Blending function and Implicit strabismus
“+”:Test mark of optical center adjustment
“+.12”:Dioptric of the Spherical Lens is +0.12m-1
*Be used for the semi-adjustment of sphere lens, 0.25m-1
“PH”:1mmPinhole lens
*Be used to exclude visual non-refractive errors of the tested eye
“6ΔU”:6ΔBottom-up prism
*Be used to examine the rotating prism with the detection of nearly horizontal squint
“10ΔI”:10ΔBottom-up prism
*Be used to examine the rotating prism with the detection of nearly horizontal squint
“±0.50”:Cross-cylindrical lens
*Be used to examine the corrected dioptric of the Presbyopia and spherical lens
“OC”:Black lens
|
size |
338(L)×99(W)×292(H)mm |
NW |
about 5kg |
| Slit Lamp with Workstation Features:
- Digital Slit lamp system, Galilean optical system, Five magnifications
- Independent image process and management software system
- More than 10 million pixel image resolution
Technical Specifications:
Microscope Type |
Galileo Parallel |
Digital System |
External Digital Slit Lamp with 10 Mega pixels |
Magnification Change Way |
Drum Five Magnifications |
Eyepiece Magnification |
12.5x |
Total Magnifications |
6x, 10x, 16x, 25x,40x |
Diopter Adjustment |
-5D ~+5D |
Slit Width |
0-14MM Continuous |
Slit Height |
1-14MM Continuous |
Slit Angle |
0°- 180° Adjustable |
Slit Inclination Angle |
5°,10°,15°, 20° |
Light Spot Diameter |
0.2mm, 2mm, 3mm, 5mm, 10mm, 14mm |
Filter |
Heat Absorption; Grey; Red free; Cobalt Blue |
Fixation |
Red LED |
Illumination Bulb |
12V/50W German OSRAM Halogen Tungsten Lamp |
| The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Features:
- The filament can be rotated for 360° and move upward and downward. The brightness of the streak can be adjusted.
- Quickly and precisely measure the astigmatism axis.
- The light can be converged, radiated, and paralleled.
- Automatic Power Off function effectively protects the bulb.
- Two-steps adjustable brightness for bulb: S(Bright) and W(Dark).
Technical Specifications:
Working Distance |
1 m |
Streak |
3 mm-20 mm |
Streak Rotation |
360° |
Illumination Source |
3V/2W, halogen bulb |
Input Voltage |
AC 220V±10%, 50Hz±1Hz |
Power Consumption |
4.5 VA |
|
Reviews
There are no reviews yet.