Automated Blood Management Refrigerator
$0.00
Shipped From Abroad
Suitable for blood transfusion departments, operating rooms, and emergency rooms, etc. of the hospitals
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Product Features
Microcomputer Control
The temperature inside the unit is controlled within 4±1°C with a temperature control accuracy of 0.1°C and the large high-definition LCD touchscreen display makes it convenient to observe.
With large viewing three-layer glass foam door design, surface glass with LOW-E film to reduce heat transfer efficiency with no condensation at 25°C and 85% humidity environment.
Multiple Fault Alarms
High/low temperature alarm, power failure alarm, door ajar, sensor error alarm, and low battery alarm. It is configured with remote alarm interface with two alarm modes (sound buzzer alarm and light flashing alarm)
Speed Control Condenser Fan
High efficiency and energy saving, low noise and long service life.
Double Protection of Mechanical Door Lock and Electromagnetic Lock
Electromagnetic lock can realize NFC card punching unlocking and fingerprint unlocking function.
Standard USB Port
With optional disc temperature recorder.
Inverter Compressor
High efficiency and energy saving, low noise and long service life.
Specifications
Model | Capacity (L/Cu.Ft) | Power Supply (V/Hz) | Display | Certificate | Type | Drawers/Baskets | Blood Bags(ml*pcs) |
HXC-149ZZ | 149/5.26 | 220-240~50 | LCD | CE | Drawer | 12 | 400*12 |
HXC-429RV | 429/15.1 | 220-240~50 | LCD | CE | Drawer | 36 | 400*36 |
HXC-629RV | 629/22.2 | 220-240~50 | LCD | CE | Drawer | 48 | 400*48 |
HXC-629RB | 629/22.2 | 115/60 | LCD | UL | Drawer | 44 | 450*88 |
HXC-429TR | 429/15.1 | 230~50/60 | LCD | – | Basket | 15 | 450*120 |
HXC-629TR | 629/22.2 | 230~50/60 | LCD | – | Basket | 24 | 450*192 |
HXC-1369TR | 429/15.1 | 230~50/60 | LCD | – | Basket | 48 | 450*384 |
Click here to download Catalogue
Quick Comparison
Automated Blood Management Refrigerator remove | Erma B-111 Bilirubin Meter remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Eppendorf Minispin Centrifuge remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | Avalun 48 INR Microcuvette remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Automated Blood Management Refrigerator remove | Erma B-111 Bilirubin Meter remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Eppendorf Minispin Centrifuge remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | Avalun 48 INR Microcuvette remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130125-29 | SF1033560084-6 | SF1033560060-2 | SF1033560084-116 | SF1033560084-30 | SF1033560084-74 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $715.00 |
|
| $9.50 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | Out of stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | Out of stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Suitable for blood transfusion departments, operating rooms, and emergency rooms, etc. of the hospitals
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Product FeaturesMicrocomputer Control
The temperature inside the unit is controlled within 4±1°C with a temperature control accuracy of 0.1°C and the large high-definition LCD touchscreen display makes it convenient to observe.
With large viewing three-layer glass foam door design, surface glass with LOW-E film to reduce heat transfer efficiency with no condensation at 25°C and 85% humidity environment.
Multiple Fault Alarms
High/low temperature alarm, power failure alarm, door ajar, sensor error alarm, and low battery alarm. It is configured with remote alarm interface with two alarm modes (sound buzzer alarm and light flashing alarm)
Speed Control Condenser Fan
High efficiency and energy saving, low noise and long service life.
Double Protection of Mechanical Door Lock and Electromagnetic Lock
Electromagnetic lock can realize NFC card punching unlocking and fingerprint unlocking function.
Standard USB Port With optional disc temperature recorder. Inverter Compressor
High efficiency and energy saving, low noise and long service life.
Specifications
Click here to download Catalogue | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | Twenty Five (25) Test Strip per Pack | LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.