Automatic CLIA System AI-180
$0.00
Shipped From Abroad
The AI‑180 is a high-speed, fully automated CLIA analyzer delivering 180 tests/hour with STAT support. It features magnetic bead technology, 20 reagent slots, and 50-sample capacity. With smart automation, it’s ideal for hospital labs and emergency diagnostics requiring rapid, reliable, and continuous testing.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The AI‑180 Automatic CLIA System is a high-throughput, fully automated chemiluminescence immunoassay analyzer engineered for large-scale clinical laboratories. With a testing capacity of up to 180 tests per hour and support for 50 onboard samples, it ensures rapid, accurate diagnostics for a wide range of analytes. Powered by acridinium ester technology and magnetic bead separation, the AI‑180 delivers excellent sensitivity, stability, and low background noise. It features 20 refrigerated reagent positions, intelligent reaction cup handling, and STAT sample support, enabling efficient urgent testing. Automation is further enhanced with barcode recognition, clot and blockage detection, and a dual-probe system to prevent cross-contamination. The user-friendly touchscreen interface and bidirectional LIS/HIS connectivity streamline operations and data exchange. Ideal for use in hospitals, emergency departments, and reference labs, the AI‑180 combines speed, automation, and precision in a compact yet powerful platform designed for modern diagnostic environments.
Features and Specifications
Feature | Specification |
---|---|
Throughput | Up to 180 tests per hour |
Sample Capacity | 50 onboard samples + STAT support |
Reagent Positions | 20 refrigerated (2–8 °C) |
Detection Method | Magnetic bead separation + acridinium ester chemiluminescence |
First Result Time | Approx. 11 minutes |
Reaction Cup Handling | 1,000 disposable cups per run (automatic loading) |
Probes | Double-needle system (sample/reagent) with anti-carryover protection |
Safety Features | Clot detection, liquid-level sensing, blockage and collision prevention |
Connectivity | Bidirectional LIS/HIS, Windows-based software |
Dimensions & Weight | 1035 × 750 × 790 mm; approx. 200 kg |
Quick Comparison
Automatic CLIA System AI-180 remove | Erma B-111 Bilirubin Meter remove | Hawksley 1400 Haematocrit Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Avalun LabPad Device remove | 8 Bucket Centrifuge remove | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Automatic CLIA System AI-180 remove | Erma B-111 Bilirubin Meter remove | Hawksley 1400 Haematocrit Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Avalun LabPad Device remove | 8 Bucket Centrifuge remove | ||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||
SKU | SF1033560084-6 | SF1033560084-118 | SF1033560060-2 | SF1033560084-65 | SF1033560084-114 | |||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||
Price |
| $715.00 | $690.00 |
|
| $72.50 | ||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
The AI‑180 is a high-speed, fully automated CLIA analyzer delivering 180 tests/hour with STAT support. It features magnetic bead technology, 20 reagent slots, and 50-sample capacity. With smart automation, it's ideal for hospital labs and emergency diagnostics requiring rapid, reliable, and continuous testing. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||||||||||||||||||||||
Content | The AI‑180 Automatic CLIA System is a high-throughput, fully automated chemiluminescence immunoassay analyzer engineered for large-scale clinical laboratories. With a testing capacity of up to 180 tests per hour and support for 50 onboard samples, it ensures rapid, accurate diagnostics for a wide range of analytes. Powered by acridinium ester technology and magnetic bead separation, the AI‑180 delivers excellent sensitivity, stability, and low background noise. It features 20 refrigerated reagent positions, intelligent reaction cup handling, and STAT sample support, enabling efficient urgent testing. Automation is further enhanced with barcode recognition, clot and blockage detection, and a dual-probe system to prevent cross-contamination. The user-friendly touchscreen interface and bidirectional LIS/HIS connectivity streamline operations and data exchange. Ideal for use in hospitals, emergency departments, and reference labs, the AI‑180 combines speed, automation, and precision in a compact yet powerful platform designed for modern diagnostic environments. Features and Specifications
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.