AVE-320 Vaginal Secretions Analyzer
$0.00
Shipped From Abroad
The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Parameters Detected
Microscopy Measurement
- RBC, WBC, Epithelial Cells, Clue Cells, Trichomonas Vaginalis, Bacteria, Fungus, Cleanliness,Bacterial Density and Diversity, Dominant Bacteria, Pathogenic Microorganisms, Nugent score, AV score, etc.
Chemistry Measurement
- pH:An important indicator reflecting the micro-ecologicalbalance of vaginal.
- H2O2:Used to assess the quantity of dominant lactobacillus for maintaining vaginal micro-ecological balance.
- Leukocyte Esterase(LE):Inflammatory response markerreflecting the quantity of WBC in vaginal secretions.
- Alkaline Phosphatase(ALP):Positive results indicate vaginal inflammation.
- Neuraminidase(SNa):Secreted by gardnerella vaginalis and some anaerobic bacteria.It’san indicator of pathogenic bacteria, positive results indicate bacterial vaginosis.
- β-Glucuronidase(β-G):An enzyme secreted by aerobic bacteria, positive results indicate aerobic vaginitis.
- Proline Aminopeptidase(PLD):Positive results indicate colpomycosis or anaerobic vaginitis.
- Acetylglucosaminidase(NAG):An specific enzyme secreted by fungi and trichomoniasis, together with reference to pH, fungal vaginitis(pH<4.5)and trichomonas vaginitis(pH>5.0)can be indicated.
- Coagulase(CG):An enzyme synthesized and secreted by aerobic bacteria,of which positive results indicate aerobic vaginitis.
Work Principle
Microscopy Measurement:Â Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically.
Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.
Product Features
Integrated
- Unique design of integration, chemistry measurement and microscopy measurement can be done by one stop sampling with easier operation and more precise results.
Multifunctional
- Measurement modes optional: chemistry or microscopy alone or chemistry and microscopy together
More results
- Chemistry and Microscopy measurements done together makes comprehensive score of vaginal micro-ecological environment, improves the rate of clinical diagnosis, confirm the type of vaginitis by one stop and guide the clinical treatments.
Chemistry Measurement
- Automatic incubation and results interpretation effectively avoid the possibility of human interference.
- Flexible options of rapid test kits in accordance with clinical purpose.
Microscopy Measurement
- Full-view field scanning and automated locating under LP, and automated tracking, identifying, classifying and counting of particles under HP to increase positive detection rate
- Comprehensive report with both full-view field and segmented images, on-screen verification of suspicious particles and no manual microscopic review required.
- Accuracy of automatic identification can be continuously improved by software upgrading.
Technical Parameters
- Throughput: ≥120 tests/h
- Detection rate: ≥90% for sample at concentration of 5 cells/µl
- Accuracy: For microscopy measurement -≥95%
- For chemistry measurement –Testing results and the reference solution are within 1 tolerance level; no false positive and false negative.
Repeatability:
For microscopy measurement:
concentration(cells/μl) |  50 |         200 |
(CV%) | ≤25% |        ≤15% |
For chemistry measurement: CV≤1%
- Carryover: for microscopy measurement- at concentration of 5000cells/ul:≤1cells/µl
- for chemistry measurement- cross test of negative and positive reference solution, no false positive
- Report: comprehensive report showing both images and diagrams, with microscopy images, morphological analysis results, chemistry results
- Sampler:Loading capacity of 60 samples in racks
- STAT: available
- Result storage:≥1,000,000 results
- Printer:External laser
- Interfaces:Bidirectional data transmission with LIS/HIS
- Network function:connectable to the networks of laboratory and hospital to realize paperless transmission of reports
Quick Comparison
Settings | AVE-320 Vaginal Secretions Analyzer remove | Plastic Urine Container Per Pack remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | Alcohol Pad Per Pack remove | Eppendorf Pipette Tip 20ul Per Pack remove | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | AVE-320 Vaginal Secretions Analyzer remove | Plastic Urine Container Per Pack remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | Alcohol Pad Per Pack remove | Eppendorf Pipette Tip 20ul Per Pack remove | ||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||
SKU | SF1033560084-106 | SF1033560084-28 | SF1033560084-30 | SF1033560084-64 | SF1033560084-136 | |||||||
Rating | ||||||||||||
Price |
| $8.20 |
| $9.50 | $4.25 |
| ||||||
Stock | ||||||||||||
Availability | ||||||||||||
Add to cart | ||||||||||||
Description | Shipped From Abroad
The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
| In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||
Content | Parameters DetectedMicroscopy Measurement
Work PrincipleMicroscopy Measurement:Â Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically. Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.Product FeaturesIntegrated
Technical Parameters
|
|
All-in-One Design
| Twenty Five (25) Test Strip per Pack | Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
|
| ||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
Additional information |
Reviews
There are no reviews yet.