Features
  • Air temperature servo control w/ override (25-37 oC)
  • Skin temperature servo control w/ override (34-37 oC)
  • Humidity pad (450 ml)
  • Glass-like transparent double wall hood
  • Hood with front & side access door
  • Hood with 2 noiseless, easy-to-open hand ports / windows
  • Hood with 1 iris ports / windows
  • Hood with 6 tube ports
  • Drawable cradle with foam mattress
  • Fixing straps
  • Heavy duty stand with 4 castors (2 lockable, 3 height level, 95 – 132 cm)
  • Gas cylinder holder (2 pcs)
  • IV pole
  • HEPA air filter
  • Water resistant, foil-covered keypad with lock
  • LED display for heating level/power/mode/lock/alarm
  • 3 digit LED display for air/skin/battery and set
  • Display of heating intensity
  • Microprocessor controller
  • Mains /Ambulance power cord
  • Battery for 90 min operation time
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • 110-120/220-230V/50-60Hz, 12V, 24V
Properties

1.  Standard Configuration

Main body includes the hood, controller, bassinet, internal battery and observation lamp, skin temperature sensor, IV pole, mattress, adjustable stand

2. Specifications

  • Air mode (temperature range: 25–37ºC, in override mode 37–38ºC) and Skin mode (temperature range: 34–37ºC, in override mode 37–37.5ºC) controlled by micro-computer;
  • Power supply AC230V/50Hz and DC12V/10A or DC24V/6A alternatively.
  • Input power: 400VA;
  • Set temperature, air temperature, skin temperature and internal battery voltage can be displayed separately;
  • Failure alarm indication: over-temperature, temperature deviation, sensor, motor fan failure, power failure;
  • Double wall acrylic glass hood with side door, the bassinet can be pulled out;
  • Natural air flow humidity;
  • The height of complete unit can be adjusted;
  • Oxygen cylinder and oxygen supply configuration;
  • Observation lamp
  • HEPA Air filter

3. Options

  • > 37ºC override temperature control mode
  • Reusable / Disposable skin temperature sensor
  • Oxygen cylinders with supply system
  • Additional battery for longer operation
  • Ambulance trolley
  • PIP and PEEP controlled resuscitator
  • O2/air blender
  • Neonatal ventilator (only with ambulance trolly)
  • Suction unit (only with ambulance trolly)
  • Syringe pump (only with ambulance trolly)
  • Ambulance aircraft base (custom design

 

Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Incubator body
Height / Packing 56/75 cm (22/30 in)
Width / Packing 96/109 cm (38/43 in)
Depth / Packing 56/65 cm (22/26 in)
Weight / Packing 65/80 kg (143/176 lbs)
Standard trolley
Height / Packing 95-132/39 cm (37-52/15 in)
Width / Packing 133/138 cm (52/54 in)
Depth / Packing 54/61 cm (21/24 in)
Weight / Packing 37/45 kg (82/99 lbs)
Ambulance trolley
Height / Packing 95-140/41 cm (37-55/16 in)
Width / Packing 192/210 cm (76/83 in)
Depth / Packing 54/28 cm (21/11 in)
Weight / Packing 43/67 kg (95/148 lbs)
Mains voltage 220/230V ±10% (default), 110/120V ±10% (upon request), 12V/10 Ah, 24V/6 Ah (Ambulance)
Nominal frequency 50/60Hz
Nominal power consumption 400VA
Number of batteries 1 pce (2 pcs as option)
Working time of battery 90 min
Number of battery charge cycles max. 200
Charging voltage of battery 12V/26AH
Dimension of battery 17x16x13 cm (7x6x5 in)
Weight of battery 9 kg
Operating ambient temperature range +10°C–+30°C (50°F–86°F)
Storage/transport ambient temperature range -40°C–70°C (-40°F–158°F)
Operating (Storage) ambient RH range 30%–75% (0%–93%)
Operating (Storage) air pressure range 800 hPa–1060 hPa (500 hPa–1060 hPa)
HOOD / IV POLE SPECIFICATIONS
Access door opening height 23 cm (9 in)
Mattress tray size 35 x 63 cm (14 x 25 in)
Mattress to hood height 26 cm (10 in)
Mattress size 30 x 60 cm (12 x 24 in)
Load of cradle max. 10 kg
Load of IV pole max. 2 kg
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 5.0°C (41.0°F) to 65.0°C (149.0°F)
Air mode control temperature range 25.0°C (77.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6°F) to 38.0°C (100.4°F), in 0.1°C increments
Skin mode control temperature range 34.0°C (93.2°F) to 37.0°C (98.6°F), in 0.1°C increments
Skin mode control override temperature range 37.0°C (96.8°F) to 37.5°C (99.5°F), in 0.1°C incr
PERFORMANCE
Air flow velocity across mattress under 30 cm/sec
Temperature rise time 22°C (72°F) ambient < 30 min
Temperature variability under 1°C (1.8°F)
Temperature uniformity on the surface of the mattress under 1.5°C (2.7°F)
Correlation of the indicated air temperature with the actual incubator temperature ≤ 1.5°C (2.7°F)
Operating noise level in hood under 50 dBA
Carbon Dioxide (CO2) level (per EN60601-2-19) under 0,5%
Micro air intake filter HEPA
DEVICE CLASSIFICATION
Protection class Class I, Type BF, continuous operation
Ingress of liquids IPX0
ALARMS
Power Failure Alarm, Fan Motor Alarm, Sensor Failure Alarm, Overheat Alarm, Deviation Alarm, Low Voltage Alarm, System Alarm

 

 

Reviews

There are no reviews yet.

Be the first to review “Baby Transport Incubator BLF-2001T”

Your email address will not be published. Required fields are marked *

Quick Comparison

Baby Transport Incubator BLF-2001T removeScrub Suit removeFirst Aid Box Aluminium Large removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeNihon Kohden Neuropack S3 Electromyogram (EMG) Machine removeSyringe Bulb remove
NameBaby Transport Incubator BLF-2001T removeScrub Suit removeFirst Aid Box Aluminium Large removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeNihon Kohden Neuropack S3 Electromyogram (EMG) Machine removeSyringe Bulb remove
ImageOPTIKA B-382PL-ALC Binocular Brightfeld MicroscopeElectromyogram (EMG) Machine
SKUSF1033560130129-2SF1033560084-202SF1033560084-251SF1033560098-13SF1033560020-3SF1033560084-205
Rating
Price

$0.00

$11.00

$69.50

$0.00

$0.00

$1.99

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it contains items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from abroad The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
  • Air temperature servo control w/ override (25-37 oC)
  • Skin temperature servo control w/ override (34-37 oC)
  • Humidity pad (450 ml)
  • Glass-like transparent double wall hood
  • Hood with front & side access door
  • Hood with 2 noiseless, easy-to-open hand ports / windows
  • Hood with 1 iris ports / windows
  • Hood with 6 tube ports
  • Drawable cradle with foam mattress
  • Fixing straps
  • Heavy duty stand with 4 castors (2 lockable, 3 height level, 95 - 132 cm)
  • Gas cylinder holder (2 pcs)
  • IV pole
  • HEPA air filter
  • Water resistant, foil-covered keypad with lock
  • LED display for heating level/power/mode/lock/alarm
  • 3 digit LED display for air/skin/battery and set
  • Display of heating intensity
  • Microprocessor controller
  • Mains /Ambulance power cord
  • Battery for 90 min operation time
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • 110-120/220-230V/50-60Hz, 12V, 24V
Properties
1.  Standard Configuration Main body includes the hood, controller, bassinet, internal battery and observation lamp, skin temperature sensor, IV pole, mattress, adjustable stand 2. Specifications
  • Air mode (temperature range: 25–37ºC, in override mode 37–38ºC) and Skin mode (temperature range: 34–37ºC, in override mode 37–37.5ºC) controlled by micro-computer;
  • Power supply AC230V/50Hz and DC12V/10A or DC24V/6A alternatively.
  • Input power: 400VA;
  • Set temperature, air temperature, skin temperature and internal battery voltage can be displayed separately;
  • Failure alarm indication: over-temperature, temperature deviation, sensor, motor fan failure, power failure;
  • Double wall acrylic glass hood with side door, the bassinet can be pulled out;
  • Natural air flow humidity;
  • The height of complete unit can be adjusted;
  • Oxygen cylinder and oxygen supply configuration;
  • Observation lamp
  • HEPA Air filter
3. Options
  • > 37ºC override temperature control mode
  • Reusable / Disposable skin temperature sensor
  • Oxygen cylinders with supply system
  • Additional battery for longer operation
  • Ambulance trolley
  • PIP and PEEP controlled resuscitator
  • O2/air blender
  • Neonatal ventilator (only with ambulance trolly)
  • Suction unit (only with ambulance trolly)
  • Syringe pump (only with ambulance trolly)
  • Ambulance aircraft base (custom design
 
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Incubator body
Height / Packing 56/75 cm (22/30 in)
Width / Packing 96/109 cm (38/43 in)
Depth / Packing 56/65 cm (22/26 in)
Weight / Packing 65/80 kg (143/176 lbs)
Standard trolley
Height / Packing 95-132/39 cm (37-52/15 in)
Width / Packing 133/138 cm (52/54 in)
Depth / Packing 54/61 cm (21/24 in)
Weight / Packing 37/45 kg (82/99 lbs)
Ambulance trolley
Height / Packing 95-140/41 cm (37-55/16 in)
Width / Packing 192/210 cm (76/83 in)
Depth / Packing 54/28 cm (21/11 in)
Weight / Packing 43/67 kg (95/148 lbs)
Mains voltage 220/230V ±10% (default), 110/120V ±10% (upon request), 12V/10 Ah, 24V/6 Ah (Ambulance)
Nominal frequency 50/60Hz
Nominal power consumption 400VA
Number of batteries 1 pce (2 pcs as option)
Working time of battery 90 min
Number of battery charge cycles max. 200
Charging voltage of battery 12V/26AH
Dimension of battery 17x16x13 cm (7x6x5 in)
Weight of battery 9 kg
Operating ambient temperature range +10°C–+30°C (50°F–86°F)
Storage/transport ambient temperature range -40°C–70°C (-40°F–158°F)
Operating (Storage) ambient RH range 30%–75% (0%–93%)
Operating (Storage) air pressure range 800 hPa–1060 hPa (500 hPa–1060 hPa)
HOOD / IV POLE SPECIFICATIONS
Access door opening height 23 cm (9 in)
Mattress tray size 35 x 63 cm (14 x 25 in)
Mattress to hood height 26 cm (10 in)
Mattress size 30 x 60 cm (12 x 24 in)
Load of cradle max. 10 kg
Load of IV pole max. 2 kg
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 5.0°C (41.0°F) to 65.0°C (149.0°F)
Air mode control temperature range 25.0°C (77.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6°F) to 38.0°C (100.4°F), in 0.1°C increments
Skin mode control temperature range 34.0°C (93.2°F) to 37.0°C (98.6°F), in 0.1°C increments
Skin mode control override temperature range 37.0°C (96.8°F) to 37.5°C (99.5°F), in 0.1°C incr
PERFORMANCE
Air flow velocity across mattress under 30 cm/sec
Temperature rise time 22°C (72°F) ambient < 30 min
Temperature variability under 1°C (1.8°F)
Temperature uniformity on the surface of the mattress under 1.5°C (2.7°F)
Correlation of the indicated air temperature with the actual incubator temperature ≤ 1.5°C (2.7°F)
Operating noise level in hood under 50 dBA
Carbon Dioxide (CO2) level (per EN60601-2-19) under 0,5%
Micro air intake filter HEPA
DEVICE CLASSIFICATION
Protection class Class I, Type BF, continuous operation
Ingress of liquids IPX0
ALARMS
Power Failure Alarm, Fan Motor Alarm, Sensor Failure Alarm, Overheat Alarm, Deviation Alarm, Low Voltage Alarm, System Alarm
   
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
 
  • Category: Doctor General Wear, Nurse Wear, Attendant Wear, Hospital Staff Wear, Ot Room Wear
  •  Color: Blue, Green, Magenta , Light Teal, Light Green, Sky blue, Ocean blue, Coral Pink
  •  Size: Small, Medium, Large, XL, XXL
  •  Gender: Male
  •  Material: Polycotton
  •  Sleeve Type: Half
  •  Pattern: Closed
  •  Disposable: No
  •  Neck Type: "V" Neck
  • Wash Care: Do Not Bleach, Machine Wash, Hand Wash
 
First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.Observation mode: Brightfield. Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged). Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 N-PLAN 100x/1.25 (Oil/Water) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Features:
  • State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms
  • Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals
  • Electrode input impedance of 200 MΩ ±20% helps ensure clean signals
  • On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations
  • HL7® gateway integration helps ensure quick flow of information and streamlines workflow
  • Intuitive control panel and stimulators aid in acquiring and progressing through studies
  • Customizable protocols shorten examination time
  • One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values
  • Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations
  • Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage
  Technical Specifications: Main unit: DC-960B Electrode junction box, 2 or 4 ch: JB-962B or JB-964B Control unit, desktop: GG-961BK Power supply: SC-230BK Cart: KD-026A Arm: KH-960A Holder: DI-961B Somato control box: RY-960B LCD display: Local purchase Printer: Local purchase Number of channels: 2 or 4 Input impedance Common mode: >100 MΩ Differential Mode: >200 MΩ CMRR Differential Mode: >106 dB Isolation Mode: >112 dB Noise level: 0.6 μVrms Sampling Resolution: 18 bit Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div. Low-cut filter: 0.01 Hz to 3 kHz High-cut filter: 10 kHz to 20 kHz Analysis time base: 0.1 ms/div to 1 s /div Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation  
Click Here To Download Catalogue
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
  • Disposable syringe for aspiration and irrigation
  • Ideal for suctioning a newborn's airway
  • Sterile
  • Bulb Aspirator Syringe. - Supplied in sealed pack - Sterile.
  • Latex Free Bulb aspirator Syringe - Essential part of any Whelping kit.
  • Quickly and hygienically removes fluids from mouth and throat of puppies & Kittens.
  • Nasal aspirator to clear nose in babies.
  • Can be used to wash ulcers.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare