Baby Transport Incubator BLF-2001T

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130129-2
Brands:: MEDICOR

Description

Features
  • Air temperature servo control w/ override (25-37 oC)
  • Skin temperature servo control w/ override (34-37 oC)
  • Humidity pad (450 ml)
  • Glass-like transparent double wall hood
  • Hood with front & side access door
  • Hood with 2 noiseless, easy-to-open hand ports / windows
  • Hood with 1 iris ports / windows
  • Hood with 6 tube ports
  • Drawable cradle with foam mattress
  • Fixing straps
  • Heavy duty stand with 4 castors (2 lockable, 3 height level, 95 – 132 cm)
  • Gas cylinder holder (2 pcs)
  • IV pole
  • HEPA air filter
  • Water resistant, foil-covered keypad with lock
  • LED display for heating level/power/mode/lock/alarm
  • 3 digit LED display for air/skin/battery and set
  • Display of heating intensity
  • Microprocessor controller
  • Mains /Ambulance power cord
  • Battery for 90 min operation time
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • 110-120/220-230V/50-60Hz, 12V, 24V
Properties

1.  Standard Configuration

Main body includes the hood, controller, bassinet, internal battery and observation lamp, skin temperature sensor, IV pole, mattress, adjustable stand

2. Specifications

  • Air mode (temperature range: 25–37ºC, in override mode 37–38ºC) and Skin mode (temperature range: 34–37ºC, in override mode 37–37.5ºC) controlled by micro-computer;
  • Power supply AC230V/50Hz and DC12V/10A or DC24V/6A alternatively.
  • Input power: 400VA;
  • Set temperature, air temperature, skin temperature and internal battery voltage can be displayed separately;
  • Failure alarm indication: over-temperature, temperature deviation, sensor, motor fan failure, power failure;
  • Double wall acrylic glass hood with side door, the bassinet can be pulled out;
  • Natural air flow humidity;
  • The height of complete unit can be adjusted;
  • Oxygen cylinder and oxygen supply configuration;
  • Observation lamp
  • HEPA Air filter

3. Options

  • > 37ºC override temperature control mode
  • Reusable / Disposable skin temperature sensor
  • Oxygen cylinders with supply system
  • Additional battery for longer operation
  • Ambulance trolley
  • PIP and PEEP controlled resuscitator
  • O2/air blender
  • Neonatal ventilator (only with ambulance trolly)
  • Suction unit (only with ambulance trolly)
  • Syringe pump (only with ambulance trolly)
  • Ambulance aircraft base (custom design

 

Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Incubator body
Height / Packing 56/75 cm (22/30 in)
Width / Packing 96/109 cm (38/43 in)
Depth / Packing 56/65 cm (22/26 in)
Weight / Packing 65/80 kg (143/176 lbs)
Standard trolley
Height / Packing 95-132/39 cm (37-52/15 in)
Width / Packing 133/138 cm (52/54 in)
Depth / Packing 54/61 cm (21/24 in)
Weight / Packing 37/45 kg (82/99 lbs)
Ambulance trolley
Height / Packing 95-140/41 cm (37-55/16 in)
Width / Packing 192/210 cm (76/83 in)
Depth / Packing 54/28 cm (21/11 in)
Weight / Packing 43/67 kg (95/148 lbs)
Mains voltage 220/230V ±10% (default), 110/120V ±10% (upon request), 12V/10 Ah, 24V/6 Ah (Ambulance)
Nominal frequency 50/60Hz
Nominal power consumption 400VA
Number of batteries 1 pce (2 pcs as option)
Working time of battery 90 min
Number of battery charge cycles max. 200
Charging voltage of battery 12V/26AH
Dimension of battery 17x16x13 cm (7x6x5 in)
Weight of battery 9 kg
Operating ambient temperature range +10°C–+30°C (50°F–86°F)
Storage/transport ambient temperature range -40°C–70°C (-40°F–158°F)
Operating (Storage) ambient RH range 30%–75% (0%–93%)
Operating (Storage) air pressure range 800 hPa–1060 hPa (500 hPa–1060 hPa)
HOOD / IV POLE SPECIFICATIONS
Access door opening height 23 cm (9 in)
Mattress tray size 35 x 63 cm (14 x 25 in)
Mattress to hood height 26 cm (10 in)
Mattress size 30 x 60 cm (12 x 24 in)
Load of cradle max. 10 kg
Load of IV pole max. 2 kg
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 5.0°C (41.0°F) to 65.0°C (149.0°F)
Air mode control temperature range 25.0°C (77.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6°F) to 38.0°C (100.4°F), in 0.1°C increments
Skin mode control temperature range 34.0°C (93.2°F) to 37.0°C (98.6°F), in 0.1°C increments
Skin mode control override temperature range 37.0°C (96.8°F) to 37.5°C (99.5°F), in 0.1°C incr
PERFORMANCE
Air flow velocity across mattress under 30 cm/sec
Temperature rise time 22°C (72°F) ambient < 30 min
Temperature variability under 1°C (1.8°F)
Temperature uniformity on the surface of the mattress under 1.5°C (2.7°F)
Correlation of the indicated air temperature with the actual incubator temperature ≤ 1.5°C (2.7°F)
Operating noise level in hood under 50 dBA
Carbon Dioxide (CO2) level (per EN60601-2-19) under 0,5%
Micro air intake filter HEPA
DEVICE CLASSIFICATION
Protection class Class I, Type BF, continuous operation
Ingress of liquids IPX0
ALARMS
Power Failure Alarm, Fan Motor Alarm, Sensor Failure Alarm, Overheat Alarm, Deviation Alarm, Low Voltage Alarm, System Alarm

 

 

Reviews

There are no reviews yet.

Be the first to review “Baby Transport Incubator BLF-2001T”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBaby Transport Incubator BLF-2001T removeSyringe Needle Destroyer removeDirty Linen Trolley removeStainless Steel Hospital Two Step Stool removeUrine Analyzer removeMedical Safety Google remove
NameBaby Transport Incubator BLF-2001T removeSyringe Needle Destroyer removeDirty Linen Trolley removeStainless Steel Hospital Two Step Stool removeUrine Analyzer removeMedical Safety Google remove
Image
SKUSF1033560130129-2SF1033560084-206SF1033560084-226SF1033560084-204SF1033560084-224SF1033560084-196
Rating
Price

$0.00

$157.00

$76.00

$27.00

$540.00

$1.99

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Features:
  • Extra-wide tops
  • Chrome-plated, reinforced base
  • Dimensions:  Top & Bottom step - 17.25in H x 17.25in W x 26.50in L
  • Weight capacity: 600 lbs.
  • Skid resistant rubber mat for safety
Manufacturer warranty: 5 years
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
  • Air temperature servo control w/ override (25-37 oC)
  • Skin temperature servo control w/ override (34-37 oC)
  • Humidity pad (450 ml)
  • Glass-like transparent double wall hood
  • Hood with front & side access door
  • Hood with 2 noiseless, easy-to-open hand ports / windows
  • Hood with 1 iris ports / windows
  • Hood with 6 tube ports
  • Drawable cradle with foam mattress
  • Fixing straps
  • Heavy duty stand with 4 castors (2 lockable, 3 height level, 95 - 132 cm)
  • Gas cylinder holder (2 pcs)
  • IV pole
  • HEPA air filter
  • Water resistant, foil-covered keypad with lock
  • LED display for heating level/power/mode/lock/alarm
  • 3 digit LED display for air/skin/battery and set
  • Display of heating intensity
  • Microprocessor controller
  • Mains /Ambulance power cord
  • Battery for 90 min operation time
  • Visual and audible alarms and backup sensors
  • Continuous self-test function during operation
  • 110-120/220-230V/50-60Hz, 12V, 24V
Properties
1.  Standard Configuration Main body includes the hood, controller, bassinet, internal battery and observation lamp, skin temperature sensor, IV pole, mattress, adjustable stand 2. Specifications
  • Air mode (temperature range: 25–37ºC, in override mode 37–38ºC) and Skin mode (temperature range: 34–37ºC, in override mode 37–37.5ºC) controlled by micro-computer;
  • Power supply AC230V/50Hz and DC12V/10A or DC24V/6A alternatively.
  • Input power: 400VA;
  • Set temperature, air temperature, skin temperature and internal battery voltage can be displayed separately;
  • Failure alarm indication: over-temperature, temperature deviation, sensor, motor fan failure, power failure;
  • Double wall acrylic glass hood with side door, the bassinet can be pulled out;
  • Natural air flow humidity;
  • The height of complete unit can be adjusted;
  • Oxygen cylinder and oxygen supply configuration;
  • Observation lamp
  • HEPA Air filter
3. Options
  • > 37ºC override temperature control mode
  • Reusable / Disposable skin temperature sensor
  • Oxygen cylinders with supply system
  • Additional battery for longer operation
  • Ambulance trolley
  • PIP and PEEP controlled resuscitator
  • O2/air blender
  • Neonatal ventilator (only with ambulance trolly)
  • Suction unit (only with ambulance trolly)
  • Syringe pump (only with ambulance trolly)
  • Ambulance aircraft base (custom design
 
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION)
Incubator body
Height / Packing 56/75 cm (22/30 in)
Width / Packing 96/109 cm (38/43 in)
Depth / Packing 56/65 cm (22/26 in)
Weight / Packing 65/80 kg (143/176 lbs)
Standard trolley
Height / Packing 95-132/39 cm (37-52/15 in)
Width / Packing 133/138 cm (52/54 in)
Depth / Packing 54/61 cm (21/24 in)
Weight / Packing 37/45 kg (82/99 lbs)
Ambulance trolley
Height / Packing 95-140/41 cm (37-55/16 in)
Width / Packing 192/210 cm (76/83 in)
Depth / Packing 54/28 cm (21/11 in)
Weight / Packing 43/67 kg (95/148 lbs)
Mains voltage 220/230V ±10% (default), 110/120V ±10% (upon request), 12V/10 Ah, 24V/6 Ah (Ambulance)
Nominal frequency 50/60Hz
Nominal power consumption 400VA
Number of batteries 1 pce (2 pcs as option)
Working time of battery 90 min
Number of battery charge cycles max. 200
Charging voltage of battery 12V/26AH
Dimension of battery 17x16x13 cm (7x6x5 in)
Weight of battery 9 kg
Operating ambient temperature range +10°C–+30°C (50°F–86°F)
Storage/transport ambient temperature range -40°C–70°C (-40°F–158°F)
Operating (Storage) ambient RH range 30%–75% (0%–93%)
Operating (Storage) air pressure range 800 hPa–1060 hPa (500 hPa–1060 hPa)
HOOD / IV POLE SPECIFICATIONS
Access door opening height 23 cm (9 in)
Mattress tray size 35 x 63 cm (14 x 25 in)
Mattress to hood height 26 cm (10 in)
Mattress size 30 x 60 cm (12 x 24 in)
Load of cradle max. 10 kg
Load of IV pole max. 2 kg
TEMPERATURE CONTROL MODES
Temperature control modes Air (standard) / Skin (option)
Temperature display range (Air/Skin mode) 5.0°C (41.0°F) to 65.0°C (149.0°F)
Air mode control temperature range 25.0°C (77.0°F) to 37.0°C (98.6°F), in 0.1°C increments
Air mode control override temperature range 37.0°C (98.6°F) to 38.0°C (100.4°F), in 0.1°C increments
Skin mode control temperature range 34.0°C (93.2°F) to 37.0°C (98.6°F), in 0.1°C increments
Skin mode control override temperature range 37.0°C (96.8°F) to 37.5°C (99.5°F), in 0.1°C incr
PERFORMANCE
Air flow velocity across mattress under 30 cm/sec
Temperature rise time 22°C (72°F) ambient < 30 min
Temperature variability under 1°C (1.8°F)
Temperature uniformity on the surface of the mattress under 1.5°C (2.7°F)
Correlation of the indicated air temperature with the actual incubator temperature ≤ 1.5°C (2.7°F)
Operating noise level in hood under 50 dBA
Carbon Dioxide (CO2) level (per EN60601-2-19) under 0,5%
Micro air intake filter HEPA
DEVICE CLASSIFICATION
Protection class Class I, Type BF, continuous operation
Ingress of liquids IPX0
ALARMS
Power Failure Alarm, Fan Motor Alarm, Sensor Failure Alarm, Overheat Alarm, Deviation Alarm, Low Voltage Alarm, System Alarm
   
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Features:
  • Extra-wide tops
  • Chrome-plated, reinforced base
  • Dimensions:  Top & Bottom step - 17.25in H x 17.25in W x 26.50in L
  • Weight capacity: 600 lbs.
  • Skid resistant rubber mat for safety
Manufacturer warranty: 5 years
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare