Benchtop Conductivity Meter, 3 Calibration Points

$0.00

Shipped From Abroad

Model : CON-B12DW

The benchtop conductivity meter is affordable and easy to use and is ideal for daily conductivity measurements of laboratory samples.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-124
Brands:: Scitek

Description

Benchtop Conductivity Meter Features:

This is an economical conductivity meter with 1 to 3 point calibration for laboratory use. It can customize the menu with 6 parameters suitable for measuring conductivity values of various samples with 1% F.S. accuracy.

  1. High-definition display for clear visualization of parameters.
  2. Automatic endpoint lock, retains stable readings for easy viewing and recording.
  3. 1 to 3 point calibration automatically recognizes conductivity standards.
  4. Reset function automatically restores meter to factory default settings.
  5. Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
  6. Setup menu to customize the number of calibration points, electrode constants, temperature units and more.

 

Benchtop Conductivity Meter Specifications:
Model CON-B12DW
Conductivity
Range 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±1% F.S.
Calibration Points 1 to 3 points
Calibration Solutions 10µS, 84µS, 1413µS, 12.88mS, 111.8mS
Temperature
Range 0 to 105℃/32 to 221°F
Resolution 0.1℃/0.1°F
Accuracy ±1℃/±1.8°F
Offset Calibration 1 point
Calibration Range Reading ±10℃
General Specifications
Temperature Compensation 0 to 100℃/32 to 212°F, manual or automatic
Temperature Coefficient Linear (0.0 to 10.0%/℃)
Reference Temperature 25℃
Cell Constant K=0.1, 1, 10 or custom
Hold Function Manual or auto-endpoint
Connector 6-pin mini-DIN, 3.5mm jack socket
Display Custom LCD (120x60mm)
Power DC9V, using AC adapter, 220V/50Hz
Sizes(W×D×H) 210x205x75
Shipping Size (W×D×H)(mm) 300x250x200
N.W./G.W. (kg) 1.5/2

Reviews

There are no reviews yet.

Be the first to review “Benchtop Conductivity Meter, 3 Calibration Points”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBenchtop Conductivity Meter, 3 Calibration Points removeAlcohol Pad Per Pack removeiSED Fully Automated ESR Analyzer removePlastic Urine Container Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeEppendorf Minispin Centrifuge remove
NameBenchtop Conductivity Meter, 3 Calibration Points removeAlcohol Pad Per Pack removeiSED Fully Automated ESR Analyzer removePlastic Urine Container Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeEppendorf Minispin Centrifuge remove
Image
SKUSF1033560130127-124SF1033560084-64SF1033560084-129SF1033560084-106SF1033560060-2SF1033560084-116
Rating
Price

$0.00

$4.25

$0.00

$8.20

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : CON-B12DW The benchtop conductivity meter is affordable and easy to use and is ideal for daily conductivity measurements of laboratory samples.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Benchtop Conductivity Meter Features:
This is an economical conductivity meter with 1 to 3 point calibration for laboratory use. It can customize the menu with 6 parameters suitable for measuring conductivity values of various samples with 1% F.S. accuracy.
  1. High-definition display for clear visualization of parameters.
  2. Automatic endpoint lock, retains stable readings for easy viewing and recording.
  3. 1 to 3 point calibration automatically recognizes conductivity standards.
  4. Reset function automatically restores meter to factory default settings.
  5. Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
  6. Setup menu to customize the number of calibration points, electrode constants, temperature units and more.
 
Benchtop Conductivity Meter Specifications:
Model CON-B12DW
Conductivity
Range 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±1% F.S.
Calibration Points 1 to 3 points
Calibration Solutions 10µS, 84µS, 1413µS, 12.88mS, 111.8mS
Temperature
Range 0 to 105℃/32 to 221°F
Resolution 0.1℃/0.1°F
Accuracy ±1℃/±1.8°F
Offset Calibration 1 point
Calibration Range Reading ±10℃
General Specifications
Temperature Compensation 0 to 100℃/32 to 212°F, manual or automatic
Temperature Coefficient Linear (0.0 to 10.0%/℃)
Reference Temperature 25℃
Cell Constant K=0.1, 1, 10 or custom
Hold Function Manual or auto-endpoint
Connector 6-pin mini-DIN, 3.5mm jack socket
Display Custom LCD (120x60mm)
Power DC9V, using AC adapter, 220V/50Hz
Sizes(W×D×H) 210x205x75
Shipping Size (W×D×H)(mm) 300x250x200
N.W./G.W. (kg) 1.5/2
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare