Description | Shipped From Abroad
Model : PH-B25C; PH-B3C; PH-B3B
Ideal for routine experiments, the benchtop pH meter is easy to operate and affordable.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Benchtop pH Meter Features:
Economical benchtop pH meter, 2 point calibration, for routine pH measurements.
Functional features:
- 2 point key calibration, automatic recognition of standard buffers.
- Optional USA or NIST standard buffer sets.
- Automatic electrode slope display for prompt replacement of electrodes.
Benchtop pH Meter Specifications:
Model |
PH-B25C |
PH-B3C |
PH-B3B |
pH Range |
0.00~14.00pH |
0.00~14.00pH |
0.00~14.00pH |
pH Accuracy |
±0.05pH |
±0.01pH |
±0.01pH |
Resolution |
0.01pH |
0.01pH |
0.01pH |
Calibration Points |
2 points |
2 points |
2 points |
Calibration Solutions |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
Temperature Compensation |
0~100°C,Manual |
0~100°C, Manual |
0~100°C, Manual or Automatic |
mV Range |
-1999~1999mV |
-1999~1999mV |
-1999~1999mV |
mV Accuracy |
±10mV |
±1mV |
±1mV |
Resolution |
1mV |
1mV |
1mV |
Temperature Rage |
/ |
/ |
0~100°C |
Temperature Accuracy |
/ |
/ |
±1°C |
Resolution |
/ |
/ |
1℃ |
Hold Function |
/ |
/ |
/ |
Connector |
BNC |
BNC |
BNC |
Display |
LCD |
LCD |
LCD |
Power Requirements |
DC9V/400mA power adapter |
DC9V/400mA power adapter |
DC9V/400mA power adapter |
Sizes (W×D×H)(mm) |
210×205×65 |
210×205×65 |
210×205×65 |
Shipping Size (W×D×H)(mm) |
320x260x200 |
N.W./G.W. (kg) |
1.5/2 |
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
- Speed: 11,800rpm with 24- place rotor
- RCF: 14,000g with 24-place rotor
- Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
- Brake: Automatic
- Noise: 62dB running with 24-place rotor
- Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
- Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
- Weight: 5.1Kg net (without rotor)
- Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
- Construction: Aluminium casing with a steel lid
- Finish: Body cream white baked enamel, with matt black baked enamel lid
|
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital | Features:
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Technical Specification:
Model: IB-9025A
Working size: 250x250x250mm/9.84x9.84x9.84inch
Power: 150W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-9999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension: 380x370x580mm/14.96x14.57x22.83inch
Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in
Gross Weight:42kg / 93lb
Net Weight: 23kg / 51lb
Warranty: 1 year | Twenty Five (25) Test Strip per Pack | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
Reviews