| Description | Shipped From Abroad
Model : PH-B25C; PH-B3C; PH-B3B
Ideal for routine experiments, the benchtop pH meter is easy to operate and affordable.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content | Benchtop pH Meter Features:
Economical benchtop pH meter, 2 point calibration, for routine pH measurements.
Functional features:
- 2 point key calibration, automatic recognition of standard buffers.
- Optional USA or NIST standard buffer sets.
- Automatic electrode slope display for prompt replacement of electrodes.
Benchtop pH Meter Specifications:
| Model |
PH-B25C |
PH-B3C |
PH-B3B |
| pH Range |
0.00~14.00pH |
0.00~14.00pH |
0.00~14.00pH |
| pH Accuracy |
±0.05pH |
±0.01pH |
±0.01pH |
| Resolution |
0.01pH |
0.01pH |
0.01pH |
| Calibration Points |
2 points |
2 points |
2 points |
| Calibration Solutions |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
USA (pH4.01/7.00/10.01) |
| Temperature Compensation |
0~100°C,Manual |
0~100°C, Manual |
0~100°C, Manual or Automatic |
| mV Range |
-1999~1999mV |
-1999~1999mV |
-1999~1999mV |
| mV Accuracy |
±10mV |
±1mV |
±1mV |
| Resolution |
1mV |
1mV |
1mV |
| Temperature Rage |
/ |
/ |
0~100°C |
| Temperature Accuracy |
/ |
/ |
±1°C |
| Resolution |
/ |
/ |
1℃ |
| Hold Function |
/ |
/ |
/ |
| Connector |
BNC |
BNC |
BNC |
| Display |
LCD |
LCD |
LCD |
| Power Requirements |
DC9V/400mA power adapter |
DC9V/400mA power adapter |
DC9V/400mA power adapter |
| Sizes (W×D×H)(mm) |
210×205×65 |
210×205×65 |
210×205×65 |
| Shipping Size (W×D×H)(mm) |
320x260x200 |
| N.W./G.W. (kg) |
1.5/2 |
| Features:
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Technical Specification:
Model: IB-9025A
Working size: 250x250x250mm/9.84x9.84x9.84inch
Power: 150W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-9999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension: 380x370x580mm/14.96x14.57x22.83inch
Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in
Gross Weight:42kg / 93lb
Net Weight: 23kg / 51lb
Warranty: 1 year | Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
- Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
- Max. speed: 14,100 x g (14,500 rpm)
- Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
- Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
- Rotor can be autoclaved at 121°C for 20 minutes
- Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
- Eliminate costly repairs with the low maintenance drive
- Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
| Speed: |
800 – 13,400 rpm (100 rpm steps) |
| Capacity: |
12 x 1.5/2.0 mL |
| Electrical: |
120 V, 60 Hz |
| Dimensions: |
(W x D x H) 22.6 x 23.9 x 12.0 cm |
| Weight: |
4.3 kg |
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
- Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
- Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
- Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
- Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
- For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
- For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
- Not for eyes;
- keep out of reach of children;
- For external use only;
- please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Specification - CE&ISO13485
|
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
Reviews