Description | Shipped From Abroad
Model : PH-B120; PHI-B130; ION-B131
This Benchtop pH Meter with 5-Point Calibration is a laboratory instrument used for precise pH measurements. It offers high accuracy and stability, often used in research and quality control settings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Benchtop pH Meter Features:
Different
- PH-B120: Customize 15 function parameters
- PH-B130: Customize 18 function parameters
- ION-B131: Customize 15 function parameters
Same
- 7-inch TFT display, high-definition and intuitive
- 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffers
- Automatic temperature compensation
- Automatic calibration date, time and 1-point offset calibration
- Large storage capacity of up to 1000 entries
- Solution temperature coefficient, compensates for pure water measurements and converts readings up to 25°C.
- Automatic alarm for measurements above the set range
Benchtop pH Meter Specifications:
Model |
PH-B120 |
PHI-B130 |
ION-B131 |
pH |
Range |
-2.000-20.000pH |
-2.000-20.000pH |
_ |
Resolution |
0.001,0.01, selectable |
0.001,0.01, selectable |
_ |
Accuracy |
±0.002pH |
±0.002pH |
_ |
Calibration Points |
1 to 5 points |
1 to 5 points |
_ |
Ph Buffer Options |
USA, NIST, DIN, 5 custom buffers |
USA, NIST, DIN, 5 custom buffers |
_ |
ORP |
mV Range |
±2000.0mV |
±2000.0mV |
±2000.0mV |
Relative mV Range |
±2000.0mV |
±2000.0mV |
_ |
Resolution |
0.1mV |
0.1mV |
0.1mV |
Accuracy |
±0.2mV |
±0.2mV |
±0.2mV |
Calibration Points |
1 point |
1 point |
_ |
Ion |
Range |
_ |
0.001~30000 (depending on the range of ISE) |
0.001~30000 (depending on the range of ISE) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001, 0.01, 0.1, 1 |
Accuracy |
_ |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
Measurement |
_ |
ppm, mg/L, mol/L, mmol/L |
ppm, mg/L, mol/L, mmol/L |
Units |
Calibration Points |
_ |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
Measurement Methods |
_ |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Electrode Management |
_ |
1 to 3 electrodes |
1 to 3 electrodes |
Water Hardness |
Range |
_ |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001,0.01,0.1,1 |
Accuracy |
_ |
±1% F.S. |
±1% F.S. |
Calibration Points |
_ |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
Temperature |
Range |
0~105°C / 32~221°F |
0~105°C / 32~221°F |
0~105°C/32~221°F |
Resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
0.1°C/0.1°F |
Accuracy |
±05°C/0.9°F |
±05°C/0.9°F |
±05°C/0.9°F |
Offset Calibration |
1 point, reading ±10°C |
1 point, reading ±10°C |
1 point, reading ±10°C |
Other Specifications |
Temperature Compensation |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
Solution Temperature Coefficient |
25°C |
25°C |
_ |
Stability Criteria |
Standard or high-accuracy |
Standard or high-accuracy |
Standard or high-accuracy |
Calibration Due Alarm |
1to 31 days or off |
1to 31 days or off |
1to 31 days or off |
Interval Readings |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
Password Protection |
4digits |
4digits |
4digits |
Memory |
1000 data sets |
1000 data sets |
1000 data sets |
Communication Interface |
USB |
USB |
USB |
Connector |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
Display |
7 inches TFT LCD |
7 inches TFT LCD |
7 inches TFT LCD |
Power Requirements |
DC12V power adapter |
DC12V power adapter |
DC12V power adapter |
Sizes (W×D×H)(mm) |
240×220×80 |
240×220×80 |
240×220×80 |
Shipping Size (W×D×H)(mm) |
300x250x200 |
300x250x200 |
300x250x200 |
N.W./G.W. (kg) |
1.7/2.5 |
1.7/2.5 |
1.7/2.5 |
| Twenty Five (25) Test Strip per Pack | Features:
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Technical Specification:
Model: IB-9025A
Working size: 250x250x250mm/9.84x9.84x9.84inch
Power: 150W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-9999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension: 380x370x580mm/14.96x14.57x22.83inch
Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in
Gross Weight:42kg / 93lb
Net Weight: 23kg / 51lb
Warranty: 1 year | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
| HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.
Feature
- LCD Backlight
- Small Blood Sample
- Splash Proof
- Strip Ejection
- Hgb/Hct
- Fast Result
Specification
- Measurement Range: 0-24.0 g/dL
- Power Supply: 3A battery X 2
- Testing Time (seconds): 5 seconds
- Sample Volume (μL): 1 μL
- Memory Capabilities: 100 sets with date and time
- Operating Temperature (°C): 10 °C~40 °C
|