| Description | Shipped From Abroad
Model : PH-B120; PHI-B130; ION-B131
This Benchtop pH Meter with 5-Point Calibration is a laboratory instrument used for precise pH measurements. It offers high accuracy and stability, often used in research and quality control settings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From AboardÂ
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
| Content | Benchtop pH Meter Features:
Different
- PH-B120: Customize 15 function parameters
- PH-B130: Customize 18 function parameters
- ION-B131: Customize 15 function parameters
Same
- 7-inch TFT display, high-definition and intuitive
- 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffers
- Automatic temperature compensation
- Automatic calibration date, time and 1-point offset calibration
- Large storage capacity of up to 1000 entries
- Solution temperature coefficient, compensates for pure water measurements and converts readings up to 25°C.
- Automatic alarm for measurements above the set range
Benchtop pH Meter Specifications:
| Model |
PH-B120 |
PHI-B130 |
ION-B131 |
| pH |
Range |
-2.000-20.000pH |
-2.000-20.000pH |
_ |
| Resolution |
0.001,0.01, selectable |
0.001,0.01, selectable |
_ |
| Accuracy |
±0.002pH |
±0.002pH |
_ |
| Calibration Points |
1 to 5 points |
1 to 5 points |
_ |
| Ph Buffer Options |
USA, NIST, DIN, 5 custom buffers |
USA, NIST, DIN, 5 custom buffers |
_ |
| ORP |
mV Range |
±2000.0mV |
±2000.0mV |
±2000.0mV |
| Relative mV Range |
±2000.0mV |
±2000.0mV |
_ |
| Resolution |
0.1mV |
0.1mV |
0.1mV |
| Accuracy |
±0.2mV |
±0.2mV |
±0.2mV |
| Calibration Points |
1 point |
1 point |
_ |
| Ion |
Range |
_ |
0.001~30000 (depending on the range of ISE) |
0.001~30000 (depending on the range of ISE) |
| Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001, 0.01, 0.1, 1 |
| Accuracy |
_ |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
| Measurement |
_ |
ppm, mg/L, mol/L, mmol/L |
ppm, mg/L, mol/L, mmol/L |
| Units |
| Calibration Points |
_ |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
| Measurement Methods |
_ |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
| Electrode Management |
_ |
1 to 3 electrodes |
1 to 3 electrodes |
| Water Hardness |
Range |
_ |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
| Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001,0.01,0.1,1 |
| Accuracy |
_ |
±1% F.S. |
±1% F.S. |
| Calibration Points |
_ |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
| Temperature |
Range |
0~105°C / 32~221°F |
0~105°C / 32~221°F |
0~105°C/32~221°F |
| Resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
0.1°C/0.1°F |
| Accuracy |
±05°C/0.9°F |
±05°C/0.9°F |
±05°C/0.9°F |
| Offset Calibration |
1 point, reading ±10°C |
1 point, reading ±10°C |
1 point, reading ±10°C |
| Other Specifications |
Temperature Compensation |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
| Solution Temperature Coefficient |
25°C |
25°C |
_ |
| Stability Criteria |
Standard or high-accuracy |
Standard or high-accuracy |
Standard or high-accuracy |
| Calibration Due Alarm |
1to 31 days or off |
1to 31 days or off |
1to 31 days or off |
| Interval Readings |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
| Password Protection |
4digits |
4digits |
4digits |
| Memory |
1000 data sets |
1000 data sets |
1000 data sets |
| Communication Interface |
USB |
USB |
USB |
| Connector |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
| Display |
7 inches TFT LCD |
7 inches TFT LCD |
7 inches TFT LCD |
| Power Requirements |
DC12V power adapter |
DC12V power adapter |
DC12V power adapter |
| Sizes (W×D×H)(mm) |
240×220×80 |
240×220×80 |
240×220×80 |
| Shipping Size (W×D×H)(mm) |
300x250x200 |
300x250x200 |
300x250x200 |
| N.W./G.W. (kg) |
1.7/2.5 |
1.7/2.5 |
1.7/2.5 |
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
- Fully automated "plug-and-play" Â behavior
- Reduced blood volume (only 3µL)
- A large space for blood drop-off
- Fills up quickly, using just capillarity
- Easy handling, thanks to its 3D shape
- Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
|
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital |
FDA 510(K) & CLIA Waived
Up to 99% accuracy rate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 17 substances with adulterants or 18 without adulterants
Adulterants available
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
- Parameters: Na+,K+,Cl-, iCa++ / Li
- It works on ISE principle
- Sample Type: Whole blood, Serum, Plasma, Urine
- Low reagent consumption
- Sample requirement is only 90ul
- 60 samples per hour
- Automatic two point calibration after 4hrs and one point calibration with each sample analysis
- Air bubble detection
- Track reagents consumption and provides alerts
- For low reagent volume
- Precision testing facility to get CV and SD
- Trilevel Quality Control with LJ plots of last 30days
- Low aspiration volume
- Fast sample processing
- Accurate and Precise results
Technical Specifications:
| Parameters |
Na+, K+, Cl– /Ca++ |
| Principle |
Ion Selective Electrode (ISE) |
| Sample Type |
Analyses whole blood, serum, plasma and urine |
| Sample Volume |
≤100 µL |
| Analysis Time |
≤60 seconds |
| Throughout |
≤60 samples per hour |
| Data Link |
Serial (RS232) |
| External Interface |
USB (Keyboard, Mouse) |
| Operating Condition |
10° C to 35° C, Relative Humidity up to 85% |
| Storage Condition |
Temp: 10° C to 40° C |
| Relative Humidity |
up to 85% non- condensing |
| Power Supply |
100 to 240 VAC ±10%, 50Hz |
| Dimensions |
395 x 260 x 375 mm |
| Weight |
7.5 kg |
|
Reviews