Biological Safety Cabinet Class II A2

$0.00

Shipped From Abroad

Class II A2 biological safety cabinet is biological safety isolation equipment used in biological safety labs, It can prevent harmful or unknown biological particulate aerosol from escaping during operation, it’s suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.

  1. Protection: Operator, samples and the environment.
  2. Airflow System: 70% air recirculation, 30% air exhaust
  3. Work area: Negative pressure
  4. Standard with ULPA filter
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-36
Brands:: Scitek

Description

Class II Biological Safety Cabinet Features:
  1. UV sterilization function and timing function can be set by appointment.
  2. Automatic air speed adjustable.
  3. With memory function in case of power-failure.
  4. Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).
  5. Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.
Advantages

1.Standard with ULPA filter.

2.UV sterilization function and timing function can be set by appointment.

3.Automatic air speed adjustable.

4.With memory function in case of power-failure.

5.Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).

6.Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; blower and front window.

 

Biological Safety Cabinet Specifications:
Model BSC-IIA2-1100 BSC-IIA2-1400 BSC-IIA2-1500 BSC-IIA2-1800 BSC-IIA2-2000
External Size
(WxDxH)(mm)
1050x836x2120 1400x836x2120 1500×836×2120 1800×836×2120 2000×836×2120
Internal Size
(WxDxH)(mm)
950x666x600 1300x666x600 1400x666x600 1700x666x600 1900×666×600
Tested Opening Safety Height 200mm (8”)
Max.Opening 400mm
Work Surface Height 800mm
Airflow System 70% air recirculation, 30% air exhaust
Downflow Velocity 0.37m/s±0.025m/s
Inflow Velocity 0.55m/s±0.025m/s
Filters Two, ULPA filter, ≥99.9995% efficiency at 0.12 μm, filter life indicator
Cleanliness Grade Class 100 (ISO14644.1 Class 5)
Display LCD touch screen
Alarm Abnormal airflow velocity, ULPA filter failure, UV lamp failure, Front window at unsafe height
Front Window Motorized, Two-layer laminated toughened glass ≥ 5mm. Anti UV.
LED Lamp 30Wx2 36Wx2 36Wx2 36Wx2 36Wx2
UV Lamp 20Wx1 30Wx1 40Wx1 40Wx1 40Wx1
Max.Consumption 896W (Not include socket loading power consumption)
Illumination ≥800Lx
Sound Emission ≤65dB(A)
Power Supply AC220V, 50Hz/60Hz, 110V, 60HZ
Material External Main body: Electro-galvanized steel with antimicrobial Powder Coating
Work surface: 304 stainless steel
Standard Accessories 1. Base stand;
2. Air Velocity sensor;
3. ULPA filter;
4. LCD touch screen;
5. LED lamp×2;
6. UV lamp×1;
7. Waterprof socket×2;
8. Motorized Front window;
9. Caster;
10. Foot switch
Optional Accessories 1. Gas tap;
2. Water tap;
3. IV bar with hooksl;
4. Manual adjustable base stand;
5. Exhaust Thimble canopy and 6m Air duct assembly
Net Weight 224kg 263kg 290kg 370kg 430kg
Gross Weight 291kg 349kg 380kg 495kg 560kg
Shipping Size
(WxDxH)(mm)
1210x1140x1710 1560x1140x1710 1660x1140x1710 1960x1140x1710 2160x1140x1710
Shipping Volume
(m3)
2.4 3.1 3.3 3.8 4.2

Reviews

There are no reviews yet.

Be the first to review “Biological Safety Cabinet Class II A2”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBiological Safety Cabinet Class II A2 removeAvalun 48 INR Microcuvette removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAlcohol Pad Per Pack removeAvalun LabPad Device removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameBiological Safety Cabinet Class II A2 removeAvalun 48 INR Microcuvette removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAlcohol Pad Per Pack removeAvalun LabPad Device removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageAvalun 48 INR MicrocuvetteAvalun Labpad machine
SKUSF1033560130127-36SF1033560084-74SF1033560060-1SF1033560084-64SF1033560084-65SF1033560084-125
Rating
Price

$0.00

$0.00

$0.00

$4.25

$0.00

$1,320.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Class II A2 biological safety cabinet is biological safety isolation equipment used in biological safety labs, It can prevent harmful or unknown biological particulate aerosol from escaping during operation, it's suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
  1. Protection: Operator, samples and the environment.
  2. Airflow System: 70% air recirculation, 30% air exhaust
  3. Work area: Negative pressure
  4. Standard with ULPA filter
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Class II Biological Safety Cabinet Features:
  1. UV sterilization function and timing function can be set by appointment.
  2. Automatic air speed adjustable.
  3. With memory function in case of power-failure.
  4. Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).
  5. Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.
Advantages
1.Standard with ULPA filter. 2.UV sterilization function and timing function can be set by appointment. 3.Automatic air speed adjustable. 4.With memory function in case of power-failure. 5.Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height). 6.Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; blower and front window.  
Biological Safety Cabinet Specifications:
Model BSC-IIA2-1100 BSC-IIA2-1400 BSC-IIA2-1500 BSC-IIA2-1800 BSC-IIA2-2000
External Size (WxDxH)(mm) 1050x836x2120 1400x836x2120 1500×836×2120 1800×836×2120 2000×836×2120
Internal Size (WxDxH)(mm) 950x666x600 1300x666x600 1400x666x600 1700x666x600 1900×666×600
Tested Opening Safety Height 200mm (8”)
Max.Opening 400mm
Work Surface Height 800mm
Airflow System 70% air recirculation, 30% air exhaust
Downflow Velocity 0.37m/s±0.025m/s
Inflow Velocity 0.55m/s±0.025m/s
Filters Two, ULPA filter, ≥99.9995% efficiency at 0.12 μm, filter life indicator
Cleanliness Grade Class 100 (ISO14644.1 Class 5)
Display LCD touch screen
Alarm Abnormal airflow velocity, ULPA filter failure, UV lamp failure, Front window at unsafe height
Front Window Motorized, Two-layer laminated toughened glass ≥ 5mm. Anti UV.
LED Lamp 30Wx2 36Wx2 36Wx2 36Wx2 36Wx2
UV Lamp 20Wx1 30Wx1 40Wx1 40Wx1 40Wx1
Max.Consumption 896W (Not include socket loading power consumption)
Illumination ≥800Lx
Sound Emission ≤65dB(A)
Power Supply AC220V, 50Hz/60Hz, 110V, 60HZ
Material External Main body: Electro-galvanized steel with antimicrobial Powder Coating
Work surface: 304 stainless steel
Standard Accessories 1. Base stand; 2. Air Velocity sensor; 3. ULPA filter; 4. LCD touch screen; 5. LED lamp×2; 6. UV lamp×1; 7. Waterprof socket×2; 8. Motorized Front window; 9. Caster; 10. Foot switch
Optional Accessories 1. Gas tap; 2. Water tap; 3. IV bar with hooksl; 4. Manual adjustable base stand; 5. Exhaust Thimble canopy and 6m Air duct assembly
Net Weight 224kg 263kg 290kg 370kg 430kg
Gross Weight 291kg 349kg 380kg 495kg 560kg
Shipping Size (WxDxH)(mm) 1210x1140x1710 1560x1140x1710 1660x1140x1710 1960x1140x1710 2160x1140x1710
Shipping Volume (m3) 2.4 3.1 3.3 3.8 4.2
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare