BRAINSWAY Deep TMS H7 Coil
$0.00
Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
-
What it does
The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder.
-
How it works
TMS uses magnetic pulses to induce an electrical current in the brain’s neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment.
-
How it’s used
The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects.
-
How it’s deliveredThe treatment involves multiple sessions, each lasting about 18 minutes.
Quick Comparison
Settings | BRAINSWAY Deep TMS H7 Coil remove | Nitrogen Generator/Plant remove | BRAINSWAY Deep TMS 104 RCT System remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | Dolphin-MAX Transcranial Doppler Probe remove | BRAINSWAY Deep TMS H7 RCT Coil remove |
---|---|---|---|---|---|---|
Name | BRAINSWAY Deep TMS H7 Coil remove | Nitrogen Generator/Plant remove | BRAINSWAY Deep TMS 104 RCT System remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | Dolphin-MAX Transcranial Doppler Probe remove | BRAINSWAY Deep TMS H7 RCT Coil remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130162-5 | SF103356013077 | SF1033560130162-3 | SF10335601298-1 | SF1033560130142-2 | SF1033560130162-6 |
Rating | ||||||
Price |
|
|
|
|
|
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
| PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
ADVANTAGES OF NITROGEN GENERATORS/PLANT
Wide Range Of Applications
![]() | The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
FeaturesThe BrainsWay Deep TMS 104 RCT System has several features, including:
Click here to download Brochure | Progetti Rescue Life 9 is designed for out-of-hospital and hospital use.
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification:
General requirements
• Dimension: 335x225x360 mm
• Weight: 6.5 kg with dual batteries
• Electrical: AC 100-240 VAC, 50/60 Hz
• Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah
• Battery Operation Time:
>5 hours, with 1 battery
>10 hours with 2 batteries
• Charge Time: Max. 3 hours
• Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged
• Software: Voice and text multi-language
• Memory: Internal flash for ECG data, events and usage review
Defibrillation
• Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor)
• Impedance: Compensated, range 25-200 Ohm
• Charge time: 6 sec for 230 J with the battery fully charged
AED mode
• Energy: Fixed energy at 200 J
• Protocol: ERC 2015 CPR Guidelines with voice and text prompts
• Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
• Sensitivity: Shockable rhythm -VF > 95%, -VT > 75%
• Specificity: According to ERC 2015,
• Normal sinusoidal rhythm > 99%
• Asystole and other non-shockable rhythms > 99%
Manual mode
• Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps)
• Commands: Multifunction trim knob
• Charge and shock button in the front panel
• Operating mode: EC G «R» wave synchro or async mode
• Indicators: Battery and main led indicators
Display
• Type: High contrast TFT colour LCD 8” (800x600 dots)
• Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status
• Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring
• Bandwidth:
0.05 - 120 Hz (-3 db) in diagnostic mode
0.6 - 40 Hz (-3 db) in monitoring mode
• CMRR: > 98 dbv Input impedance: > 50 Mohm
• Input:
Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard
Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional
• Speed: 5, 10, 25, 50 mm/sec
• Filters: 50/60 Hz, EMG Filter, base line
• HR range: 20-300 bpm (~2%), digital readout on the display
• Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512)
• SpO2 range: 0-100% HR range: 30-250 bpm
• Accuracy: 70-100% ~2% for adults with finger clip sensor
• Alarm: Adjustable min 50%
Temperature
• Probe type: YSI400 compatible
• Range: 0 to 50° C
• Resolution: ±0.1° C
Standard
• IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1
• CE Mark EEC 93/42: Medical device, Class IIb
• Isolation: ECG type CF, Defibrillation type BF
• Waterproof: Class IP54
|
https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO
Features of Dolphin TCD Machine | The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
Features
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.