Description | | Shipped from abroad
The DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
SuperMark 1.5T is a new generation superconducting MRI system based on years of experience in production and research. It's applicable to whole body scan, such as, nervous system, spine, joint soft tissue, pelvic and abdominal cavity, etc
Delivery & Availability:
Typically 90 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
This Machine gives a possibility to perform computed tomography without any problems and on high quality level. This device is used to conduct exams of internal organs and their functioning. With its help, a physician has a possibility to assess the condition of the human body as a whole.
Delivery & Availability:
Typically 90 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Our Neeo “C” arms are easy to place, use and are specifically designed to be used in orthopedics, traumatology, abdominal surgery, urology, cardiology and operating rooms.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Incorporating innovative technologies, P20’s user-friendly design with a simple operation panel, intuitive user interface and a variety of intelligent auxiliary scanning tools, will significantly improve your daily examination experience. Besides general imaging applications, P20 has entitled with diagnostic 4D technology which has an extraordinary performance in obstetrics and gynecology applications.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
For gastroenterology
Rectal cannulas are made of PVC for medical use.
They are flexible and have a smooth surface. The balloon can be filled either with air than water (about 100 ml). Upon request, all cannulas can be provided with a foam pad
| DrGem Ceiling Analogue X-ray Machine is a diagnostic radiography system X-ray Machine that provides reliable high quality radiographic images with a reduced dose. The reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered.
Features of DrGem Ceiling Analogue X-ray Machine
- TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
- WBS-TA: Vertical movement
- V Stroke:1,450mm in Uprigh Bucky Position,
- 1,526mm in Horizontal Bucky position.
- PBT-4 is a 4 way Floating Tabletop with. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
Technical Specifications of DrGem Ceiling Analogue X-ray Machine
- Power Rating - 32KW
- Generator - GXR-32S
- Rotor - Dual Speed Starter(DSS)
- Input Power - 400/480VAC, Three phase
- Line Frequency - 50/60Hz
- X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
- Tube Voltage - 40 to 150kV, 1kV Step
- Tube Current – 10 to 640mA
- Output - 640mA@81kV, 500mA@104kV, 400mA@130kV, 320mA@150kV
- Time Range - 1ms to 10s
- mAs Range - 0.1 to 800mAs
- Reproducibility - Coecient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
- Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
- Linearity - Coecient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
- Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m
- PBT-4: 4 way Floating Tabletop with Elevating Feature (66cm).
- WBS-TA: a. Vertical movement
- V Stroke:1,450mm in Upright Bucky
- Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable
- Auto Collimator
| SuperMark 1.5T is a new generation superconducting MRI system based on years of experience in production and research. It's applicable to whole body scan, such as, nervous system, spine, joint soft tissue, pelvic and abdominal cavity, etc. SuperMark 1.5T provides not only conventional pulse sequences and clinical diagnosis functions, but also provides advanced functional applications, for instance, 3D angiography and water imaging. It adopts brand new ANKE APEX operating system which ensures easy operation and fast diagnosis.
Technical Advantages:
- Reliable short cavity superconducting magnet system with zero liquid helium
consumption
- New generation fully digitalized and extensible multichannel spectrometer
- Powerful high efficiency and high fidelity gradient system; Multi-channel PA RF
receiving coil with intelligent identification
- English operating system and high extensible computer system
- High resolution conventional clinical images; Practical advanced functional
imaging
Superconducting MRI System:
- Highly open and humanization design -> Streamlined design
- Rich sequences and technology satisfy clinical needs -> Efficient service
Low Investment:
- High cost performance superconducting MRI system
- Zero liquid helium consumption, low running and maintenance cost
- Core technology by independent R & D supports full upgrade
- Low electric consumption
- Compact magnet design, minimum installation space: 35 square meters
High Return:
- High resolution thin slice images improve diagnosis
- Short cavity magnet design makes patients comfortable
- Fast scan speed improves work efficiency
Technical Specifications:
No. |
Technique Description |
Parameter |
1 |
Magnet System |
|
1.1 |
Magnet Type |
Permanent Magnet
Automatic constant temperature
system |
1.2 |
Field Strength |
0.51T |
1.3 |
Magnet Shape |
Dual-pillar shape |
1.4 |
Homogeneity(40cm,DSV,VRMS) |
≤1.6ppm |
1.5 |
Shim Method |
Active/Passive |
1.6 |
Magnet Vertical Gap (Cover) |
40cm |
1.7 |
Magnetic Pole Dia. (Exclude Cover) |
145cm |
1.8 |
Accessibility(Horizontal Opening Angle, |
280° |
1.9 |
5 Gauss fringe field |
X-axis:horizontal ≤2.5m
Y-axis:Vertical ≤2.5m
Z-axis:horizontal ≤2.5m |
2 |
Patient Couch and Communication |
|
2.1 |
Patient Couch Driven mode |
Motor-driven |
2.2 |
Max. Patient Weight |
≥200kg(440lbs) |
2.3 |
Patient Positioning Tools |
Laser Light Localizer for positioning of center slice Motor-driven transfer to center of imaging volume |
2.4 |
Position accuracy |
±1mm |
2.5 |
Emergency Call Key |
Yes |
2.6 |
Intercom System |
Yes |
3 |
Gradient System |
|
3.1 |
Gradient Field Strength(Single Axis) |
≥30mT/m |
3.2 |
Gradient Slew Rate (Single Axis) |
≥100mT/m/ms |
3.3 |
Rise Time |
≤0.3ms |
3.4 |
Gradient Cooling System ( Gradient coils
and Power electronics) |
Air Cooling |
4 |
RF System |
|
4.1 |
RF System Type |
Digital Transmit and
Receive signal |
4.2 |
Number of RF Channels |
4 |
4.3 |
Transmitter Amplifier Peak Power |
6kW |
4.4 |
RF Bandwidth of Receiver |
≥1.25MHz |
4.5 |
Head Coil |
Yes |
4.6 |
Neck Coil |
Yes |
4.7 |
Body/Spine Coil (17 inch) |
Yes |
4.8 |
Body/Spine Coil (21 inch) |
Yes |
4.9 |
Knee Coil |
Yes |
4.10 |
Shoulder Coil |
Yes |
4.11 |
Flexible Coil |
Optional |
4.12 |
Breast Coil |
Optional |
5 |
Computer System |
|
5.1 |
Host Computer |
DELL Computer (for MR) |
5.2 |
System Software |
Windows XP |
5.3 |
Operation Software |
APEX |
5.4 |
CPU Clock rate |
3.0GHz |
5.5 |
Main Memory |
4GB |
5.6 |
Color LCD Monitor |
19” |
5.7 |
Keyboard and Mouse |
Standard |
5.8 |
Image Reconstruction Speed(256 x 256
Matrix) |
200 frame/Sec. |
5.9 |
Hard Disk |
500GB |
5.10 |
Image Storage Capacity(256 x 256
Matrix) |
500,000 |
5.11 |
Media Driver |
DVD RW |
5.12 |
DICOM 3.0 |
Yes |
5.13 |
Ethernet |
Yes |
5.14 |
Operation Console |
Yes |
5.15 |
Operation Chair |
Yes |
6 |
Scanning Parameter |
|
6.1 |
Max. FOV |
410mm |
6.2 |
Min. FOV |
5mm |
6.3 |
Min. TE(SE) |
5ms |
6.4 |
Min. TR(SE) |
11ms |
6.5 |
Min. TE(GR) |
1ms |
6.6 |
Min. TR(GR) |
3ms |
6.7 |
Min. 2D Thickness |
1.0mm |
6.8 |
Min. 3D Thickness |
0.1mm |
6.9 |
Max. Image Matrix |
512x512 |
7 |
Scanning Sequence & Imaging Technique |
|
7.1 |
Spin Echo 2D/3D (SE 2D/3D) |
Yes |
7.2 |
DE/QE |
Yes |
7.3 |
Fast Spin Echo 2D/3D(FSE 2D/3D) |
Yes |
7.4 |
Single Shot FSE 2D/3D |
Yes |
7.5 |
Inversion Recovery(IR) |
Yes |
7.6 |
Fast Inversion Recovery(FIR) |
Yes |
7.7 |
Gradient Echo 2D/3D(GR 2D/3D) |
Yes |
7.8 |
Fast GR 2D/3D |
Yes |
7.9 |
SPGR |
Yes |
7.10 |
FLAIR |
Yes |
7.11 |
Fat Imaging |
Yes |
7.12 |
Fat Suppression imaging |
Yes |
7.13 |
Water-Fat Separation imaging |
Yes |
7.14 |
TOF MRA(2D/3D) |
Yes |
7.15 |
MRCP(2D/3D) |
Yes |
7.16 |
MRU (2D/3D) |
Yes |
7.17 |
MRM |
Yes |
7.18 |
Fast Hydrograph Imaging |
Yes |
7.19 |
Diffusion Weighted Imaging(DWI) |
Yes |
7.20 |
Max. b Value |
1000s/mm2 |
7.21 |
Breath Hold Technology |
Yes |
7.22 |
Magnetization Transfer Contrast(MTC) |
Yes |
7.23 |
Multi-slice and Angle-free Presaturation |
Yes |
7.24 |
Saturation Tracking |
Yes |
7.25 |
Maximum Intensity Projection(MIP) |
Yes |
7.26 |
Multi-Angle Projection(MAP) |
Yes |
7.27 |
3D Reconstruction |
Yes |
7.28 |
Multi-planar Reconstruction(MPR) |
Yes |
7.29 |
Multi-Artifacts Eliminating technology |
Yes |
7.30 |
Checking with Part Metal Implant |
Yes |
7.31 |
Online Image Filtration |
Yes |
7.32 |
Online Post Procession |
Yes |
7.33 |
3D Scout |
Yes |
7.34 |
Scanning Protocol Preset |
Yes |
7.35 |
Scanning Protocol Queue Waiting |
Yes |
7.36 |
Advanced Image Post Processing |
Yes |
7.37 |
Image Fusion Technology of Vascular |
Yes |
7.38 |
Image Fusion Technology of Spine |
Yes |
| This Machine gives a possibility to perform computed tomography without any problems and on high quality level. This device is used to conduct exams of internal organs and their functioning. With its help, a physician has a possibility to assess the condition of the human body as a whole.
Features:
- It is easy to use;
- Convenience;
- Multi functionality;
- Obtained images are of high definition;
- High-definition 3D images of the area under study;
- The procedure is pain-free;
- The data is processed fast;
- The image can be stored in the computer memory;
- The diagnostics does not take a lot of time;
- Acceptable radiation dose.
Technical Specifications:
No. |
Technical Features |
Descriptions |
1 |
Gantry |
|
1.01 |
Gantry type |
Low voltage slip-ring |
1.02 |
Gantry driven type |
Strap-driven |
1.03 |
Patient opening |
70cm |
1.04 |
Gantry tilt mode |
Digital gantry tilt |
1.05 |
Digital tilt capability |
±50° |
1.06 |
Detector type |
OptiWave rare-earth ceramic detector |
1.07 |
Numbers of detector rows |
16 |
1.08 |
Width of Z-axle detector |
20mm |
1.09 |
Detector columns of channels per row |
848 |
1.10 |
Numbers of detector columns |
13568 |
1.11 |
Data-transfer type |
RF, optical fiber communication |
1.12 |
Distance of focus-ISO-center |
53cm |
1.13 |
Distance of focus-detector |
94cm |
1.14 |
3D laser orientation |
Provided |
1.15 |
13" integrated display panel |
Provided |
1.16 |
Adose automatic exposure control (mA
Modulation) |
Provided |
1.17 |
Auto-voice manager |
Breath Graphical Display
Hold Message (Record/Playback)
Breath Message (Record/Playback) |
1.18 |
AccuSaving energy conservation management |
Provided |
2 |
HVPS and X-ray tube |
|
2.01 |
Maximum continuous output of HVgenerator |
42kW |
2.02 |
Tube kV selections |
70kV, 80kV, 100 kV, 120 kV, 140 kV |
2.03 |
Tube mA range |
10~350mA |
2.04 |
Tube anode heat capacity |
3.5MHU |
2.05 |
Max. anode cooling rate |
735kHU/min |
2.06 |
Type of cooling |
Oil cooling + Air cooling |
2.07 |
Tube focus |
Large: 1.2mm×1.4mm
Small: 0.7mm×0.8mm |
2.08 |
Collimator width selection |
4-level election |
2.09 |
Focus spot tracking technology |
Provided |
3 |
Patient table |
|
3.01 |
Maximum horizontal-movable range |
1850mm |
3.02 |
Table horizontal-scannablerange |
1800mm |
3.03 |
Table horizontal-position repeatability |
±0.25mm |
3.04 |
Minimum height above floor |
430mm |
3.05 |
Maximum vertical-movable range |
500mm |
3.06 |
Maximum speed of vertical movement |
35mm |
3.07 |
Maximum speed of horizontal movement |
150mm/s |
3.08 |
Maximum patient weight |
205kg |
3.09 |
Foot pedal of patient table control |
Provided |
4 |
Computer |
|
4.01 |
CPU |
3.5GHz |
4.02 |
Memory |
32GB |
4.03 |
Storage of hard-disk |
1TB×2 |
4.04 |
Monitor |
24’’ LCD Monitor |
4.05 |
Resolution of monitor |
1920×1200 |
4.06 |
Image-data external storage type |
CD/DVD/USB |
4.07 |
Time of image reconstruction (512×512) |
33.3ms/image |
4.08 |
Speed of image reconstruction (512×12) |
30fps |
4.09 |
DICOM 3.0 interface |
Provided |
4.10 |
Printer DICOM 3.0 interface |
Provided |
4.11 |
Auto filming |
Provided |
4.12 |
Worklist function |
Provided |
5 |
Scan parameters |
|
5.01 |
Shortest 360 degree rotation time |
0.75s |
5.02 |
Allowed rotation times |
0.75s, 1.0s, 1.5s, 2.0s, 3.0s, 4.0s |
5.03 |
Maximum slice numbers per rotation |
32 |
5.04 |
Minimum slice thickness of scan |
1.25mm |
5.05 |
Minimum slice thickness of reconstruction |
0.625mm |
5.06 |
Maximum slice thickness of scan |
20mm |
5.07 |
Nominal reconstruction slice thickness |
0.625mm, 1.25mm, 2.5mm, 5.0mm, 7.5mm,
10mm, 20mm |
5.08 |
Speed of image reconstruction (512×512) |
30 frames/s |
5.09 |
Scan FOV |
50cm |
5.10 |
Image reconstruction matrix |
512×512, 1024×1024 (Optional) |
5.11 |
Image reconstruction matrix |
512×512, 1024×1024 (Optional) |
5.12 |
Image display matrix |
512×512, 1024×1024 (Optional) |
5.13 |
Maximum continuous scan duration |
120s |
5.14 |
Maximum continuous scan length |
180cm |
5.15 |
Direction of TOPO |
Front-back, Left-right |
5.16 |
Max. length of TOPO |
180cm |
5.17 |
Range of pitch |
0.5~1.5 |
5.18 |
Scan mode |
Scout scan
Axial scan
Helical scan
Cine scan |
6 |
Image Quality |
|
6.01 |
High contrast resolution |
21lp/cm@0%MTF |
6.02 |
Low contrast resolution |
2.0mm@0.30% |
6.03 |
Isotropic imaging resolution |
0.24mm |
6.04 |
Range of CT numbers |
-32767~32768 |
6.05 |
Image noise |
≤0.29@28mGy |
7 |
Advanced application |
|
7.01 |
Multi-Planar Reconstruction (MPR) |
Provided |
7.02 |
Curve Multi-Planar Reconstruction (CPR) |
Provided |
7.03 |
Surface Shaded Display (SSD) |
Provided |
7.04 |
Volume Rendering (VR) |
Provided |
7.05 |
Maximum Intensity Projection (MIP) |
Provided |
7.06 |
Minimum Intensity Projection (MinIP) |
Provided |
7.07 |
Virtual Endoscopy (VE) |
Provided |
7.08 |
CT angiography (CTA) |
Provided |
7.09 |
Tissue segmentation |
Provided |
7.10 |
One click bone remove |
Provided |
7.11 |
One click patient table remove |
Provided |
7.12 |
Bolus-tracking Technology |
Provided |
7.13 |
Spiral auto start |
Provided |
7.14 |
Cine display |
Provided |
7.15 |
AbastTM bone artifact suppression technology |
Provided |
7.16 |
AmastTM metal artifact suppression technology |
Provided |
7.17 |
Admir3D all-domain iterative reconstruction |
Provided |
7.18 |
Low-dose pediatric scan technology |
Provided |
7.19 |
Low-dose lung scan technology |
Provided |
7.20 |
AccuHead grey-white matter enhanced
technology |
Provided |
7.21 |
AccuOrgan lung high resolution scan technology |
Provided |
7.22 |
AccuOrgan inner-ear high resolution scan
technology |
Provided |
7.23 |
AccuOrgan body high resolution scan technology |
Provided |
7.24 |
AccuOrgan bone high resolution scan technology |
Provided |
7.25 |
AccuMatter dual-energy with Admir3D for new
application |
Provided |
| Our Neeo “C” arms are easy to place, use and are specifically designed to be used in orthopedics, traumatology, abdominal surgery, urology, cardiology and operating rooms.
Using Neeo with the RTP (Real Time Processing) option it is possible to perform vascular, urological and cardiological diagnostics. One of the main functions, digital image subtraction, allows to see, as an example, the passage of contrast liquids in a tissue or in a venous or arterial duct; thanks to the possibility of looping, the acquired video can be reproduced several times to monitor more accurately the passage of the fluid within the area in question. Angiographic measurement is another useful function in the vascular field (QA Quantitative Angiography) that allows the measurement of stenoses. Finally, fluoroscopy allows the correct positioning of stents or expanders.
Neeo is used in various interventional and diagnostic procedures in traumatology and orthopedics wards and operating rooms as well. Thanks to low-dose fluoroscopy, it is possible to use the device for positioning bone or subcutaneous grafts, inserting K-wire (Kirschner wire) for stabilization of bone fragments or for the correct positioning of prostheses. The low dose emitted ensures safe use for both the patient and the surgeon or doctor on the operating field.
On the control panel there is a large touch screen display that allows to adjust the basic functions of the equipment. From this display it is possible to select and adjust the fluoroscopic data for the examination, activate or deactivate the laser pointer, select between pulsed, one shot or standard fluoroscopy, rotate the image and perform all operations on collimator. The four side buttons on the display offer the possibility to move the bow vertically thanks to an extremely silent motor.
Neeo has two 19 “medical grade monitors that can be positioned according to the needs of the medical practitioner. Work monitors and feedback monitors are separated to be managed independently. The possible movements are: rotation, revolution, tilting and possibility of height adjustment.
Features:
- Continuous fluoroscopy
- Pulsed fluorography
- One Shot fluoroscopy
- Low dose fluoroscopy
- Radiography with cassette (up to 5KW)
- 110,000 images of memory (Standard)
- 19 ″ Medical Flat Monitor (X2)
- Touch control panel
- Image Processing – 1K X 1K, 16 bit
- DAP-Dose Area Meter
- DSA Road Mapping
- Laser Marker
Technical Specification:
- Power: 5KW
- kV Range (kV): 40 - 120
- mAs Range (mAs): 1 - 250
- SID (mm): 1000
- Free Space (mm): 730
DICOM Feature:
- RTP-SW DSA
- RTP-SW QA
- RTP-SW Worklist
- RTP-SW Print
- RTP-SW CD DVD Saving
- RTP-SW MPPS
- RTP-SW Query/Retrieve
- RTP-SW HCF
- RTP-SW BASE
- RTP-SW STCOMMIT
Configuration:
C-Arm Structure, Trolley for Monitor, Collimator, Monoblock, Toshiba 12” Image Intensifier, 19″ Philips Medical Flat Monitor (X2), Camera CD1030CA 1KX1K, Sony Printer UP-X898MD, Cassette Holder
| DETAILS
Upgraded Images with More Clarity
SonoScape never stops making progress in improving the image quality of its ultrasound products to enhance the confidence of diagnosis for doctors. With extraordinary images provided by P20, the anatomy structures are clearer than ever.
C-Xlasto Imaging
With C-xlasto Imaging, P20 enables comprehensive quantitative elastic analysis. Meanwhile, C-xlasto on P20 is supported by linear, convex and transvaginal probes, to ensure good reproducibility and highly consistent quantitative elastic results.
S-Live
S-Live allows for detailed visualization of subtle anatomical features, thereby enabling intuitive diagnosis with real-time 3D images and enriching patient communication.
Pelvic Floor 4D
Transperineal 4D pelvic floor ultrasound can provide useful clinical values in assessing the vaginal delivery impact on the female anterior compartment, judging whether the pelvic organs are prolapsed or not and the extent, determining if the pelvic muscles were torn accurately.
Anatomic M Mode
Anatomic M Mode helps you observe the myocardial motion at different phases by freely placing sample lines. It accurately measures the myocardial thickness and the heart size of even difficult patients and supports the myocardial function and LV wall-motion assessment.
Tissue Doppler Imaging
P20 is endowed with Tissue Doppler Imaging which provides velocities and other clinical information on myocardial functions, facilitating clinical doctors with the ability to analyze and compare the motions of different parts of the patient's heart.
|
Reviews
There are no reviews yet.