Chalazion Forceps

$0.00

Shipped From Abroad

Oval Plate, 23×16mm

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013094-32
Brands:: HASA-OPTIX

Reviews

There are no reviews yet.

Be the first to review “Chalazion Forceps”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsChalazion Forceps removePortable Rebound Tonometer removeHandheld Digital Auto-refractometer removeApplanation Tonometer removePortable Keratometer removeEar Irrigation and acumen removal remove
NameChalazion Forceps removePortable Rebound Tonometer removeHandheld Digital Auto-refractometer removeApplanation Tonometer removePortable Keratometer removeEar Irrigation and acumen removal remove
ImageMecan SW-500 Portable Rebound TonometerMecan AutoSight MCE-900 Handheld Digital AutorefractometerMecan Applanation Tonometer YZ30XMecan SW 100 Portable Keratometer
SKUSF103356013094-32SF1033560107-17SF1033560107-2SF1033560107-1SF1033560107-16SF103356013012
Rating
Price

$0.00

$1,815.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Oval Plate, 23×16mm
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: ●Professional Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly. ●Quick & Easy This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentTonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing. Features of Handheld Digital Auto-refractometer:
  • Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
  • Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
  • Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item Range Interval Tolerance
Spherical (S) Myopia Mode -9.00D~ +2.50D 0.25D ±0.50D or ±20% (whichever is greater)
Normal Mode -6.00D  ~ +8.00D
Cylindrical(C) -3.00D~0.00D 0.25D ±0.50D or ±20% (whichever is greater)
Axis(A) 0°~180° ±5°
 
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
Portable Keratometer Features: Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data. Technical Specifications:
Model SW-100
Measuring Range 6.5mm~9.5mm: ±0.05mm: 0.01mm
Precision ± 0.05mm
Resolution of Curvature Radius of Cornea 0.01mm
Single Measuring Time 0.03s
Output Wireless Infrared Thermal Printer
Can observe the eye directly through the screen.
Weight 0.5Kg(with batteries)
Dimension 240mmx90mmx60mm
Power 500mW+15%
Features: ●Professional Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly. ●Quick & Easy This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy. ●Standard Capacity of the ear cleaner solution bottle is 10.6Oz, it has the most suitable size to hold in hand. Working at condition 32-122℉(0-50℃). Recommend to fill 1/5 of the bottle with OTC hydrogen peroxide, and 4/5 with very warm water. ●Complete Ear Washer System Our earwax removal kit comes with 1× Ear Washer Bottle, 1× Wash Basin, 1× Rubber Bulb, 1× Short Injection Head, 1× Long Hose Injection Head, 5× Disposable Tip, 1× User Manual.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare