Description | Shipped From Abroad
Oval Plate, 23×16mm
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
YZ20P5 Operation Microscope is a simple binocular coaxial microscope for a single man. The Operation Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
Super lightweight design, reduce fatigue, operation is very convenient.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check archive
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | | Operation Microscope(YZ20P5) is a simple binocular coaxial microscope for a single man. The Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment.
Features of Operation Microscope:
- Multi-layer coating technology is used on optical lenses to enhance the transmission rate and prevent mildew.
- Foot-controlled focus, three-step magnification change, good depth of field of view, and good binocular fusion to meet the need of cataract surgery.
- Using apochromatic technology to make different wavelengths of the light focus near the focal point behind the lens, so as to make the operator's vision more clearly.
- The machine weighs only 41Kg to be light and compact and is especially applicable for mobile medical.
- Optional desktop components to make the machine more portable and can also be customized according to special requirements to meet the needs in ophthalmology, ENT and other surgery.
- Optional F250/F300/F400 lens.
Technical Specifications of Operation Microscope:
Eyepiece Magnification
|
12.5×
|
Focal Length of Objective Lens
|
F=200
|
Working Distance
|
190 mm
|
Magnification for Main Microscope
|
5.3×, 8×, 16×
|
Diameter of Field
|
37 mm, 25 mm, 16.7 mm
|
Diopter Adjustment
|
±5D
|
Pupillary Distance
|
50 mm ~ 70 mm
|
Maximum Resolution
|
100 LP/mm
|
Light Source
|
12V/100W halogen lamp for medical use
|
Illumination Type
|
6° coaxial illumination of the cold light source
|
Coaxial Illuminance
|
≥30,000 Lx
|
Reaching Radius of Arm
|
870 mm
|
Adjustable Vertical Range
|
700 mm~1100 mm
|
Fine Focusing Range |
30 mm |
Input Voltage
|
AC 220V/110V±10%, 50Hz/60Hz
|
Power Consumption
|
120 VA
|
Fuse
|
AC 250V T4.0A, AC 125V T8.0A
|
Electrical Safety Standard
|
IEC 60601-1, Class I
|
Packing Volume
|
0.2 m3,1 carton
|
Total Weight
|
41 kg
|
| Ophthalmoscope Features:
- LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously.
- Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite.
- Super lightweight design, reduce fatigue,operation is very convenient.
- The portable power supply is suitable for surgery, ward round and consultation.
- This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation.
Technical Specifications:
Pupilary Adjustment |
52mm~74mm adjustable |
Intensity of Illumination |
continuous adjustment with the maximum intensity no less than 500Lx |
Headband |
520~640mm in circumference, 85~125mm in depth |
Light Spots |
Big spot, middle spot and small spot |
Filters |
Red-free, white and cobalt blue |
Light Source |
LED light |
Source of Power |
Li+ battery, DC 7.4V |
AC 100~240V, 50/60Hz |
Input Power |
Battery charger: 15 VA |
AC charger: 50VA |
Dimension of Main Part |
142mm × 48mm × 128mm(long×breadth×high) |
Weight of Main Part |
230g |
| Functions of Ophthalmic AB Scan Machine:
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan |
1.Probe: 10MHz frequencies, with LED
2.Depth: 40mm
3.Precision: ±0.05mm
4.Eye mode: Phakic / Aphakic / Dense / Various IOL
5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat.
7.Calculation: Average and standard deviation
8.Store: 10 Scanning results for each eye |
B scan |
1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless
2.Scanning Mode: Sector Scanning
3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm
4.Geometric Location Precision: Lateral≤10%; Vertical≤5%
5.Depth: 60mm
6.Enhance the part of vitreous body and retina
7.Gain of probe:30dB-105dB
8.Scanning Angle : 53°
9.Gray Scale: 256
10.False Color: Multi colors OTC
11.Measure Mode: distances, perimeter and area
12.Movies: 100 images movie review,AVI ZIP JPG format image output
13.Output: PDF format case report, connect to normal printer |
Others |
1.Display Mode :B, B+B, B+A, A
2.Hint: preset keyword
3.Case Search: Multi-keywords
4.Working Platform: Windows XP, VISTA, WINDOWS7
5.User-defined report template |
| The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
- Eyepiece focusing range: ±5D
- The top point diopter measuring range: 0—±20D
- The minimum measuring square value: 0.125D
- The shuttle lens measuring range: 5A
- The shuttle lens square value: 1A
- The cylinder lens axial range: 0—180°
- The cylinder lens axial square value: 5°
- The maximum diameter of the measured lenses l00m/m
- Power supply: AC 110V-6V DC 3V
- Note: This item is AC 110V; The battery is not included!
| Feature:
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by a pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check the archive
Technical Specifications:
Model |
SW-1000 Ophthalmic A Scan Biometer |
A Scan |
A scan probe |
10MHz import small size probe, built-in luminotron |
Measuring range |
15mm-40mm |
Measurement precision |
±0. 05mm; with macula lutea trace function |
Measurement |
Anterior chamber depth, lens thickness, vitreous body length, total length and average |
Method of measurement |
immersion and contact |
Eye mode |
Phakic/ Aphakic/Dense/ various IOL |
IOL formula |
SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS |
Storage |
10 cases, 5 readings each case |
Output |
A scan waveform and IOL calculation sheet
|
|