Chalazion Forceps Serrated Handle With Locking Thumb Screw

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013094-33
Brand:
Brands:: HASA-OPTIX

Reviews

There are no reviews yet.

Be the first to review “Chalazion Forceps Serrated Handle With Locking Thumb Screw”

Your email address will not be published. Required fields are marked *

Quick Comparison

Chalazion Forceps Serrated Handle With Locking Thumb Screw removeBinocular Indirect Ophthalmoscope removePortable Rebound Tonometer removeManual lensmeter removeTonometer removeAutomatic Computer Goldmann (Visual Field Analyzer) remove
NameChalazion Forceps Serrated Handle With Locking Thumb Screw removeBinocular Indirect Ophthalmoscope removePortable Rebound Tonometer removeManual lensmeter removeTonometer removeAutomatic Computer Goldmann (Visual Field Analyzer) remove
ImageMecan YZ25C Binocular Indirect OphthalmoscopeMecan SW-500 Portable Rebound TonometerMecan Manual lensmeter NJC-4Mecan Tonometer YZ7A
SKUSF103356013094-33SF1033560107-4SF1033560107-17SF1033560107-22SF1033560107-9SF103356013013
Rating
Price

$0.00

$880.00

$1,815.00

$0.00

$220.00

$3,850.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Super lightweight design, reduce fatigue, operation is very convenient.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentOphthalmoscope Features:
  • LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously.
  • Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite.
  • Super lightweight design, reduce fatigue,operation is very convenient.
  • The portable power supply is suitable for surgery, ward round and consultation.
  • This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation.
Technical Specifications:
Pupilary Adjustment 52mm~74mm adjustable
Intensity of Illumination continuous adjustment with the maximum intensity no less than 500Lx
Headband 520~640mm in circumference, 85~125mm in depth
Light Spots Big spot, middle spot  and small spot
Filters Red-free, white and cobalt blue
Light Source LED light
Source of Power Li+ battery, DC 7.4V
AC 100~240V, 50/60Hz
Input Power Battery charger: 15 VA
AC charger: 50VA
Dimension of Main Part 142mm × 48mm × 128mm(long×breadth×high)
Weight of Main Part 230g
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth. Features:
  • Schiotz type
  • All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
  • The instrument is safe, reliable, accurate, and convenient to carry
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare