/

CO2 Fractional Laser Machine 3 In 1 System

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130105-31
Brands:: Stellelaser

Description

co2 fractional laser machine

3

Professional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3.14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8.Minimal side effects and no down time.
9.Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
Specifications
Specification Fractional CO₂ Laser
Laser type USA Coherent laser (RF Tube, lifetime 5-10 years)
Wavelength 10600nm
Systems Fractional and cutting system standard; Vaginal system optional
Output Power 1-40W
Input Power 600W
Output Graphics Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available.
Light guiding system 7 joints,360° rotation
Scanning mode Sequence, Random scanning
Spot size 0.08-0.12mm
Scan area Up to 20*20mm
Aiming beam 650nm red diode laser, laser power 0.1-5mW
Cooling system Air fan
Working Theory

Fractional Skin Resurfacing Working Theory

The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.

Vaginal Tightening Working Theory

Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.

3 in 1 System (Fractional, Cutting, Gynecology)

We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.

7 Joints 360° Rotation Light Guiding Arm

Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.

14 Graphics

14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.

14个光斑
RF Metal Laser Tube from US Coherent

In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy.

Why Choose Metal Tube Instead of Glass Tube?

Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use.

Wide treatment range of Fractional CO2 Laser

Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.

1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
2- Wrinkles (Crow’s feet, head lines, Sichuan characters, Decree lines)
3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
5- Other applications (syringoma, condyloma, seborrheic, etc.)
6- Vaginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
1
1

Reviews

There are no reviews yet.

Be the first to review “CO2 Fractional Laser Machine 3 In 1 System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Fractional Laser Machine 3 In 1 System removeQ-switched Nd:YAG laser therapy device removeCryoPen B+ removeLab/Ward Coat removeHONKON-M207 Water Oxygen Facial Cleanser removeCryoPen O remove
NameCO2 Fractional Laser Machine 3 In 1 System removeQ-switched Nd:YAG laser therapy device removeCryoPen B+ removeLab/Ward Coat removeHONKON-M207 Water Oxygen Facial Cleanser removeCryoPen O remove
Image
SKUSF1033560130105-31SF1033560130100-3SF1033560096-1SF1033560084-222SF1033560130100-10SF1033560096-3
Rating
Price

$0.00

$0.00

$0.00

$11.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Scope of application: Used to remove blue and black tattoos.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The CryoPen B+ is designed to take our biggest N2O cartridges: 23.5g. Making it ideal for treating larger or deeper lesions and for infrequent use. It’s ideal for General PractitionersPodiatrists and Veterinarians. CryoPen B+ is also suitable in a mixed medical or veterinary practice where several practitioners share the tools and want a variety of different devices.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Operation scope: Water oxygen facial cleanser 1. Clean the epidermis of the skin 2. Rehydrate and oxygenate the skin.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad All-purpose, powerful cryosurgery device for regular use. Typical users are General PractitionersDermatologists, and Podiatrists who use the CryoPen frequently. CryoPen O is also suitable in a mixed medical practice where several practitioners share the tools and want the option of different applicators and power settings.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
co2 fractional laser machine

3

Professional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3.14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8.Minimal side effects and no down time.
9.Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
Specifications
Specification Fractional CO₂ Laser
Laser type USA Coherent laser (RF Tube, lifetime 5-10 years)
Wavelength 10600nm
Systems Fractional and cutting system standard; Vaginal system optional
Output Power 1-40W
Input Power 600W
Output Graphics Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available.
Light guiding system 7 joints,360° rotation
Scanning mode Sequence, Random scanning
Spot size 0.08-0.12mm
Scan area Up to 20*20mm
Aiming beam 650nm red diode laser, laser power 0.1-5mW
Cooling system Air fan
Working Theory
Fractional Skin Resurfacing Working Theory The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.
Vaginal Tightening Working Theory Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
3 in 1 System (Fractional, Cutting, Gynecology) We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.

7 Joints 360° Rotation Light Guiding Arm

Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.

14 Graphics

14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.

14个光斑
RF Metal Laser Tube from US Coherent

In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy.

Why Choose Metal Tube Instead of Glass Tube? Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use. Wide treatment range of Fractional CO2 Laser Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.
1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
2- Wrinkles (Crow’s feet, head lines, Sichuan characters, Decree lines)
3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
5- Other applications (syringoma, condyloma, seborrheic, etc.)
6- Vaginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
1
1
https://youtu.be/YtAvbY2b4Ec?si=LNbDM8ztqz7TbL7J  

Operating range:

Used to remove blue and black tattoos.
Accessories Details:
This product consists of a main unit, a light guide arm and a foot switch; the main unit includes an Nd: YAG actively Q-switched laser, a laser power supply and control device, a safety protection system, and a cooling system (internal circulation water cooling, air conditioning heat exchanger). Working laser wavelength: 1064nm±5nm.
The CryoPen B+ is designed to take our biggest N2O cartridges: 23.5g. Making it ideal for treating larger or deeper lesions and for infrequent use. It’s ideal for General PractitionersPodiatrists and Veterinarians. CryoPen B+ is also suitable in a mixed medical or veterinary practice where several practitioners share the tools and want a variety of different devices. Supplied with 3 applicators:
  • Orange/red 1-4mm applicator
  • White/red 2-6mm applicator
  • Green/red 4-8mm applicator
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Principle of Operation

How it works:

HONKON's water oxygen cleanser fully combines oxygen and nutrient solution, and sprays water vapor mixed particles from the nozzle at a speed of 230m/s (similar to the spray form) to act on the skin. The fine particles with a diameter of about 50-80um (smaller than the diameter of the pores) clean the skin from the epidermis to the basal layer below the epidermis. If nutrients are added to the base liquid, the internal environment of the skin can be adjusted, which can replace manual skin care.  

Operating range:

1. Clean the epidermis of the skin 2. Hydrate and oxygenate the skin.  

Product advantages:

The high-pressure gas is mixed with the nutrient solution through a stainless steel needle and sprayed out water vapor particles with a diameter of about 50μm at a speed of up to 230m/s. Oxygen pressure gauge, real-time pressure display. The gas output flow control system can adjust the gas output volume and gas output pressure according to different parts. It can be used with nutrient solution products to achieve better results. The liquid output flow control system can adjust the liquid output volume and liquid output pressure according to different parts, which is more targeted.  

Technical Parameters:

Water mist particle speed: ≤230m/s Built-in air source output pressure: ≤0.8MPa Number of instruments: 4 Water mist particle diameter: ≤80um Gas source type: built-in gas source 5L gas tank Water oxygen pen: O-II Number of water oxygen pens: 2 Insurance specification: Max6A Power supply: AC220V±10%, 50HZ, AC110V±10%, 60HZ Gear: 1-2 gears adjustable, one gear step Accessories Details: O—II Water Oxygen Pen It is beautiful, easy to use, and can be repaired after damage, which reduces the user's cost of use; the deep cleaning effect is obvious; customers are advised to stock up on water oxygen pens O-Ⅱ type for emergencies.
All-purpose, powerful cryosurgery device for regular use. Typical users are General PractitionersDermatologists, and Podiatrists who use the CryoPen frequently. CryoPen O is also suitable in a mixed medical practice where several practitioners share the tools and want the option of different applicators and power settings. Supplied with 3 applicators:
  • Blue/red 1-3mm applicator
  • White/red 2-6mm applicator
  • Green/red 4-8mm applicator
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare