/

CO2 Fractional Laser Machine 3 In 1 System

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130105-31
Brands:: Stellelaser

Description

co2 fractional laser machine

3

Professional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3.14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8.Minimal side effects and no down time.
9.Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
Specifications
Specification Fractional CO₂ Laser
Laser type USA Coherent laser (RF Tube, lifetime 5-10 years)
Wavelength 10600nm
Systems Fractional and cutting system standard; Vaginal system optional
Output Power 1-40W
Input Power 600W
Output Graphics Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available.
Light guiding system 7 joints,360° rotation
Scanning mode Sequence, Random scanning
Spot size 0.08-0.12mm
Scan area Up to 20*20mm
Aiming beam 650nm red diode laser, laser power 0.1-5mW
Cooling system Air fan
Working Theory

Fractional Skin Resurfacing Working Theory

The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.

Vaginal Tightening Working Theory

Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.

3 in 1 System (Fractional, Cutting, Gynecology)

We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.

7 Joints 360° Rotation Light Guiding Arm

Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.

14 Graphics

14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.

14个光斑
RF Metal Laser Tube from US Coherent

In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy.

Why Choose Metal Tube Instead of Glass Tube?

Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use.

Wide treatment range of Fractional CO2 Laser

Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.

1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
2- Wrinkles (Crow’s feet, head lines, Sichuan characters, Decree lines)
3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
5- Other applications (syringoma, condyloma, seborrheic, etc.)
6- Vaginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
1
1

Reviews

There are no reviews yet.

Be the first to review “CO2 Fractional Laser Machine 3 In 1 System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Fractional Laser Machine 3 In 1 System removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeIntense Pulsed Light Therapy Device removeElectric Dermatome removeCryoPen M removeQ-switched Nd:YAG laser therapy device remove
NameCO2 Fractional Laser Machine 3 In 1 System removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeIntense Pulsed Light Therapy Device removeElectric Dermatome removeCryoPen M removeQ-switched Nd:YAG laser therapy device remove
Image
SKUSF1033560130105-31SF1033560096-4SF1033560130100-1SF10335601214SF1033560096-2SF1033560130100-3
Rating
Price

$0.00

$0.00

$0.00

$6,507.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Description Scope of application: Suitable for the treatment of telangiectasia and superficial pigmentation; Improvement of photoaged skin.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.   Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad This is the perfect cryosurgery tool for removing small or superficial benign lesions such as sun spots, age spots, skin tags and small warts. CryoPen M is suitable for less-frequent use or for smaller/superficial lesions. Typical users are General PractitionersDermatologists and Estheticians. CryoPen M is also suitable in a mixed medical practice where several practitioners share the tools and want a variety of different devices.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Scope of application: Used to remove blue and black tattoos.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
co2 fractional laser machine

3

Professional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3.14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8.Minimal side effects and no down time.
9.Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
Specifications
Specification Fractional CO₂ Laser
Laser type USA Coherent laser (RF Tube, lifetime 5-10 years)
Wavelength 10600nm
Systems Fractional and cutting system standard; Vaginal system optional
Output Power 1-40W
Input Power 600W
Output Graphics Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available.
Light guiding system 7 joints,360° rotation
Scanning mode Sequence, Random scanning
Spot size 0.08-0.12mm
Scan area Up to 20*20mm
Aiming beam 650nm red diode laser, laser power 0.1-5mW
Cooling system Air fan
Working Theory
Fractional Skin Resurfacing Working Theory The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.
Vaginal Tightening Working Theory Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
3 in 1 System (Fractional, Cutting, Gynecology) We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.

7 Joints 360° Rotation Light Guiding Arm

Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.

14 Graphics

14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.

14个光斑
RF Metal Laser Tube from US Coherent

In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy.

Why Choose Metal Tube Instead of Glass Tube? Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use. Wide treatment range of Fractional CO2 Laser Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.
1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
2- Wrinkles (Crow’s feet, head lines, Sichuan characters, Decree lines)
3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
5- Other applications (syringoma, condyloma, seborrheic, etc.)
6- Vaginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
1
1
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  

Operating range:

Suitable for operations on telangiectasia and superficial pigmentation: improvement of photoaged skin.

Technical Parameters:

Grip model: F+E, F+E+ Rated input power (w): 1350 Dimensions (mm): 610*340*770 Weight (Kg): 47

Accessories Details:

The equipment consists of operating tools and filters, power supply and control device, protection system, cooling system (internal circulation water cooling, fan).
Electric Dermatome
Technical Parameters: 1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.   Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use. 6. Exclusive design of pulled and plugged handle connection line, easy to use. (the length of handle connection line is greater than 3m) 7. Power supply: 220V±10% AC automatic switching, 150/60Hz single phase. Output 14.5V DC, 4.3A. 8. Degree of prevention of liquid entry: IPXO. 9. Sterilization Method: Sterilization Mode: pre-vacuum and gravity displacement steam sterilization or low temperature plasma sterilization can be conducted in whole machine and power cord. And the power cord can be pulled and plugged.
This is the perfect cryosurgery tool for removing small or superficial benign lesions such as sun spots, age spots, skin tags and small warts. CryoPen M is suitable for less-frequent use or for smaller/superficial lesions. Typical users are General PractitionersDermatologists and Estheticians. CryoPen M is also suitable in a mixed medical practice where several practitioners share the tools and want a variety of different devices. Supplied with 2 applicators:
  • Blue/red 1-3mm applicator
  • White/red 2-6mm applicator
https://youtu.be/YtAvbY2b4Ec?si=LNbDM8ztqz7TbL7J  

Operating range:

Used to remove blue and black tattoos.
Accessories Details:
This product consists of a main unit, a light guide arm and a foot switch; the main unit includes an Nd: YAG actively Q-switched laser, a laser power supply and control device, a safety protection system, and a cooling system (internal circulation water cooling, air conditioning heat exchanger). Working laser wavelength: 1064nm±5nm.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare