CO2 Fractional Laser Machine 3 In 1 System
$0.00
Shipped From Abroad
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
co2 fractional laser machine
Specifications
Specification | Fractional CO₂ Laser |
Laser type | USA Coherent laser (RF Tube, lifetime 5-10 years) |
Wavelength | 10600nm |
Systems | Fractional and cutting system standard; Vaginal system optional |
Output Power | 1-40W |
Input Power | 600W |
Output Graphics | Standard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available. |
Light guiding system | 7 joints,360° rotation |
Scanning mode | Sequence, Random scanning |
Spot size | 0.08-0.12mm |
Scan area | Up to 20*20mm |
Aiming beam | 650nm red diode laser, laser power 0.1-5mW |
Cooling system | Air fan |
Fractional Skin Resurfacing Working Theory
The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.
Vaginal Tightening Working Theory
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
3 in 1 System (Fractional, Cutting, Gynecology)
We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.
7 Joints 360° Rotation Light Guiding Arm
Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.
14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.

In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy.
Why Choose Metal Tube Instead of Glass Tube?
Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use.
Wide treatment range of Fractional CO2 Laser
Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.


Quick Comparison
Settings | CO2 Fractional Laser Machine 3 In 1 System remove | Cryotherapy Device remove | Q-switched Nd:YAG laser therapy device remove | Electric Dermatome remove | Semiconductor laser hair removal device 808CH remove | CryoPen M remove | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | CO2 Fractional Laser Machine 3 In 1 System remove | Cryotherapy Device remove | Q-switched Nd:YAG laser therapy device remove | Electric Dermatome remove | Semiconductor laser hair removal device 808CH remove | CryoPen M remove | ||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||
SKU | SF1033560130105-31 | SF10335601215 | SF1033560130100-3 | SF10335601214 | SF1033560130100-7 | SF1033560096-2 | ||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||
Price |
|
|
| $6,507.00 | $3,190.00 |
| ||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The low temperature medicine is a medical science of studying the impact of low temperature on the human tissue based on the cryobiology and applying the low temperature technique to treat diseases. Its main contents include: low temperature physiology, cryopreservation, freezing and immunization, cold injury, and low temperature cryotherapy for therapeutic Applications.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Scope of application:
Used to remove blue and black tattoos.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness
adjusting button is unilateral adjustment, with high stability and no need
calibrate to zero.
2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.
Note: Special size width plate can be customized according to requirements.
3. The blade has self-lubricating function and is easy to load and unload. It can move
back and forth smoothly to prevent metal to metal collision.
4. Original imported motor, low inertia electric motor will hardly produce any
vibration when rotating, rotate speed: 4500-5000rpm.
5. Hand held control, easy to operate; handle with contact switch design, safety to use
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Shipped From Abroad
Scope of application:
Clinically used to remove excess skin hair.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
This is the perfect cryosurgery tool for removing small or superficial benign lesions such as sun spots, age spots, skin tags and small warts. CryoPen M is suitable for less-frequent use or for smaller/superficial lesions. Typical users are General Practitioners, Dermatologists and Estheticians. CryoPen M is also suitable in a mixed medical practice where several practitioners share the tools and want a variety of different devices.
| ||||||||||||||||||||||||||
Content | co2 fractional laser machineProfessional clinic use Fractional CO2 Laser with 3 systems
1. Fractional and cutting 2 systems standard; Gynecology system optional
2. Umanized software control, more effective in treatment results
3.14 variable treatment graphics, adjustable shapes, sizes and spacing
4. 7 Joints articulated light guiding arm; Convenient and flexible in operation, greatly reducing energy loss
5. USA imported RF laser tube; steady and even laser output
6. 1-3 times Fast and effective solve scar and vagical problem.
7. 360 degree scanning ability of fractional handle .
8.Minimal side effects and no down time.
9.Wide application for treatment of dermatology, gynecology, general surgery, ENT and anorectal etc.
Specifications
Working Theory
Fractional Skin Resurfacing Working Theory
The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.
Vaginal Tightening Working Theory
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
3 in 1 System (Fractional, Cutting, Gynecology)
We have fractional and cutting 2 systems as standard configuration; gynecology system as optional.
7 Joints 360° Rotation Light Guiding Arm Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction. 14 Graphics
14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments. ![]() RF Metal Laser Tube from US Coherent
In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 30-40W RF Metal tube from US Coherent, ensure powerful and stable energy. Why Choose Metal Tube Instead of Glass Tube? Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use. Wide treatment range of Fractional CO2 Laser Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…)
2- Wrinkles (Crow’s feet, head lines, Sichuan characters, Decree lines)
3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting
4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.)
5- Other applications (syringoma, condyloma, seborrheic, etc.)
6- Vaginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)
![]() ![]() | The low temperature medicine is a medical science of studying the impact of low temperature on the human tissue based on the cryobiology and applying the low temperature technique to treat diseases. Its main contents include: low temperature physiology, cryopreservation, freezing and immunization, cold injury, and low temperature cryotherapy for therapeutic Applications.
Technical Specification:
Display: 12 inch touch screen
Treatment time: 1 min- 99 min, adjustable
Airflow output: 1-10 levels adjustable, 30L/min-120L/min, range 10L/min
Standby Situation: -14ºC~-22ºC
Automatic defrosting: Every two hour
Treatment mode: Customized mode and preset mode
Liquid level detection: Condensated water level is detected, overflow is warned
Therapeutic Effect:
> Lower body temperature >> Analgesic spasmolytic >> Destructive effect >> Relieve local congestion or bleeding >> Control the spread of inflammation to diminish it >> Stop itching and sedation >> Immunization.Therapeutic Techniques: (I) Ice bag sticking method It is quite simple and the most commonly used method, which is widely used in the clinical treatment. (II) Cold and heat hot pack Put the tower into the cold water or ice water, wring it to semi-dry (namely, no water drops), and apply it to the affected area. Application scopes and contraindications are the same as above. (III) Chemical refrigeration bag (IV) Tetrachloroethane jetting (V) Local soaking method (VI) Cold bath from head to foot (VII) Body cavity method | https://youtu.be/YtAvbY2b4Ec?si=LNbDM8ztqz7TbL7J
Operating range: Used to remove blue and black tattoos.Accessories Details:
This product consists of a main unit, a light guide arm and a foot switch; the main unit includes an Nd: YAG actively Q-switched laser, a laser power supply and control device, a safety protection system, and a cooling system (internal circulation water cooling, air conditioning heat exchanger). Working laser wavelength: 1064nm±5nm. | Electric DermatomeTechnical Parameters: 1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm. Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use. 6. Exclusive design of pulled and plugged handle connection line, easy to use. (the length of handle connection line is greater than 3m) 7. Power supply: 220V±10% AC automatic switching, 150/60Hz single phase. Output 14.5V DC, 4.3A. 8. Degree of prevention of liquid entry: IPXO. 9. Sterilization Method: Sterilization Mode: pre-vacuum and gravity displacement steam sterilization or low temperature plasma sterilization can be conducted in whole machine and power cord. And the power cord can be pulled and plugged. |
https://youtu.be/g_iaT3jxtFI?si=AJ6CJrNeG_PMhiaJ
Operating range:
Clinically used to remove excess skin hair.
Accessories Details:
The equipment consists of a host, operating tools and foot switches. The host includes a semiconductor laser, a switching power supply, a laser power supply, a control system, a detection system, a cooling system and a laser transmission system. | This is the perfect cryosurgery tool for removing small or superficial benign lesions such as sun spots, age spots, skin tags and small warts. CryoPen M is suitable for less-frequent use or for smaller/superficial lesions. Typical users are General Practitioners, Dermatologists and Estheticians. CryoPen M is also suitable in a mixed medical practice where several practitioners share the tools and want a variety of different devices.
Supplied with 2 applicators:
| ||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.