CO2 Sidestream Module Capno-S

$0.00

Shipped From Abroad

A side stream EtCO2 sensor, accurate and durable, suitable for various complex environments. Compatible with multiple protocols. Plug and play, no zero calibration required. Stable and durable.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of CO2 Sidestream Module Capno-S
  • Plug And Play

There is no circuit inside the host, just a serial port.

  • High Precision

Temperature pressure compensation, timing and self-calibration functions, full-range calibration, to ensure accurate measurement within the range of 0-20%

Long Service Life And Extremely Low Noise

The gas circuit, hardware and software are carefully designed to ensure the long-term stability of the module

Low Power Consumption

Suitable for battery-powered use, automatic pressure compensation. Maintain measurement accuracy in an extremely wide air pressure range of 400-960mmHg.

Patented Water Filters

The Filters can work continuously for a long time, and can be reused, reducing the user’s cost.

Dedicated Fi-lock Air Inlet Interface

Intelligent identification and light indication of filter insertion and breathing status.

 

Complete EtCO2 OEM Solutions

Multiple communication protocols, and more than 20 years of accumulated technology and experience, easily help you achieve technical and practical improvements

 

Specifications of CO2 Sidestream Module Capno-S
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5°C to 40°C, 30 to 75% RH, non-condensing
Circumstance pressure 55-115 KPa
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption Usual typical value 120 mA during deviation and calibration, typical value 280 mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 – 40 mmHg ± 2 mmHg

41 – 70 mmHg ± 5% of reading

71 – 100 mmHg ± 8% of reading

101 – 150 mmHg ± 10% of reading

Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 2 min.
Rise time <200ms
Calibration No routine user calibration required
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%

 

Application Scenarios of CO2 Sidestream Module Capno-S
  • High signal-to-noise ratio

Capno-S is a side stream CO2 module.

It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit and Software Algorithms to achieve gas concentration measurement with high signal-to-noise ratio;

  • Long continuous working time

For side stream modules, there are built-in long-life sampling pumps, ensuring a one-way flow of exhaled air; and a high-quality filter that can work for a long time even in a high-temperature environment.

  • Plug-and-play

It can be used in conjunction with a multi-parameter monitor. The monitor only needs one interface, which can be connected to the module for use.

  • Atmospheric pressure compensation

There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments;

  • OEM solutions

We provide reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled.

Reviews

There are no reviews yet.

Be the first to review “CO2 Sidestream Module Capno-S”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Sidestream Module Capno-S removeBunsen Burner removeVolumetric Flask 250ml removeOptika B-190TB Digital Binocular Microscope removeChemical Weighing Balance removePipette Holder remove
NameCO2 Sidestream Module Capno-S removeBunsen Burner removeVolumetric Flask 250ml removeOptika B-190TB Digital Binocular Microscope removeChemical Weighing Balance removePipette Holder remove
ImageOptika B-190TB Digital Binocular Microscope
SKUSF1033560084-155SF1033560084-187SF1033560098-5SF1033560084-190SF1033560084-148
Rating
Price

$0.00

$4.25

$4.10

$0.00

$658.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad A side stream EtCO2 sensor, accurate and durable, suitable for various complex environments. Compatible with multiple protocols. Plug and play, no zero calibration required. Stable and durable.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Item: Bunsen Burner
  • Btu Output: 800 - 1200
  • Overall Height: 6-1/8"
  • Fuel Type: Natural
  • Barb Size: 7/16"
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Material Borosilicate Glass
Shape Cylindrical
Capacity 250 ml
Usage/Application Chemical Laboratory,Industrial
Maximum Temprature Capacity 400 degeree C
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Digital binocular microscope ideal for teachers and secondary schools, with four achromatic lenses (1000x), FN 18 high eyepoint, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 3 W X-LED2 illumination.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock This is a 210g/0.001g Analytical electronic chemical balance for industrial and scientific field.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The linear and round stands have been designed to fit perfectly of TOPTION Pipette range, TopPette,MicroPette and MicroPette Plus Autoclavable Pipettes. The stands are convenient to hold up 6 pipettes both of single and multi-channel.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of CO2 Sidestream Module Capno-S
  • Plug And Play
There is no circuit inside the host, just a serial port.
  • High Precision
Temperature pressure compensation, timing and self-calibration functions, full-range calibration, to ensure accurate measurement within the range of 0-20%
Long Service Life And Extremely Low Noise
The gas circuit, hardware and software are carefully designed to ensure the long-term stability of the module
Low Power Consumption
Suitable for battery-powered use, automatic pressure compensation. Maintain measurement accuracy in an extremely wide air pressure range of 400-960mmHg.
Patented Water Filters
The Filters can work continuously for a long time, and can be reused, reducing the user's cost.
Dedicated Fi-lock Air Inlet Interface
Intelligent identification and light indication of filter insertion and breathing status.  
Complete EtCO2 OEM Solutions
Multiple communication protocols, and more than 20 years of accumulated technology and experience, easily help you achieve technical and practical improvements  
Specifications of CO2 Sidestream Module Capno-S
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5°C to 40°C, 30 to 75% RH, non-condensing
Circumstance pressure 55-115 KPa
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption Usual typical value 120 mA during deviation and calibration, typical value 280 mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 2 min.
Rise time <200ms
Calibration No routine user calibration required
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%
 
Application Scenarios of CO2 Sidestream Module Capno-S
  • High signal-to-noise ratio
Capno-S is a side stream CO2 module. It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit and Software Algorithms to achieve gas concentration measurement with high signal-to-noise ratio;
  • Long continuous working time
For side stream modules, there are built-in long-life sampling pumps, ensuring a one-way flow of exhaled air; and a high-quality filter that can work for a long time even in a high-temperature environment.
  • Plug-and-play
It can be used in conjunction with a multi-parameter monitor. The monitor only needs one interface, which can be connected to the module for use.
  • Atmospheric pressure compensation
There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments;
  • OEM solutions
We provide reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled.
  • Item: Bunsen Burner
  • Btu Output: 800 - 1200
  • Overall Height: 6-1/8"
  • Fuel Type: Natural
  • Barb Size: 7/16"
Material Borosilicate Glass
Shape Cylindrical
Capacity 250 ml
Usage/Application Chemical Laboratory,Industrial
Maximum Temprature Capacity 400 degree C
Digital binocular microscope ideal for teachers and secondary schools, with four achromatic lenses (1000x), FN 18 high eyepoint, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 3 W X-LED2 illumination. The 3.1 MP CMOS camera ensures excellent colour reproduction and is connected to a Windows tablet PC with vivid color graphic display for unparalleled comfort and performance. The tablet represents a 2-in-1 solution as it can be disconnected and used as a real PC, being Windowsbased, with powerful Intel processor and large touch screen of 10.1” for fast, responsive and smooth control. Features:
  • Observation mode: Brightfield.
  • Head: Binocular, 360° rotating and 30° inclined. Interpupillary distance from 48 to 75 mm; dioptric adjuctment on left eyepiece. Built-in 3.1 MP camera.
  • Eyepieces: WF 10x/18 mm, secured by screw.
  • Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
  • Objectives: HC – High Contrast Achromatic 4x/0.10 with anti-fungus treatment. HC – High Contrast Achromatic 10x/0.25 with anti-fungus treatment. HC – High Contrast Achromatic 40x/0.65 with anti-fungus treatment. HC – High Contrast Achromatic 100x/1.25 (Oil/Water) with anti-fungus treatment.
  • Specimen stage: Double layer mechanical sliding stage, 125×115 mm, 70×30 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1mm.
  • Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
  • Condenser: Abbe N.A. 1.25, pre-centered, adjustable height with iris diaphragm.
  • Illumination: X-LED² with white 3 W LED and light intensity control. Color temperature: 6,300 K. Multi-plug 100-240Vac/6Vdc external power supply. Color temperature: 6,300 K.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Binocular (Siedentopf)
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 48-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 18
  Magnification 10x
  Pointer As optional
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 20
  High eyepoint (for glass wearers) Yes
Nosepiece Positions Quadruple
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system 160
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-400x
  Type HC
  Objectives included 4x/0.10, W.D. 18 mm 10x/0.25, W.D. 7 mm 40x/0.65, W.D. 0.53 mm
  100x/1.25 (Oil/Water) W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 125x116
  Moving mechanism Rack and pinion
  Moving range (mm) 70x30
  Material Anti-scratch painting
  Specimen clips Yes
  Slide number 1
  X-Y movement Yes
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Single Position Type Abbe
  Numerical aperture (N.A.) 1.25
  Centrable Pre-centered
  Focusable By rotation
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 18
  Fine total travel (per single rotation) (mm) 0.4
  Fine graduations 100
  Fine resolution (µm) 4
  Upper stop to prevent contact Yes
  Adjustable tension Yes
Transmitted Illumination Type X-LED
  X-LED type X-LED2
  Light source power (W) 3
  Brightness control Manual
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 6
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 6 Vdc  2.5A
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  User Manual Digital version (downloadable)
  Calibration slide Yes
  Touch pen Yes
  USB cable (m) 0.5
Additional Information External rechargeable battery pack (as optional). Tablet Keyboard (as optional).
Product Weight Height (mm) 525
  Width (mm) 260
  Depth (mm) 320
Product Weight (kg) 7.5
Camera specifications PC Camera resolution (MP) 3.1
  Camera resolution (n° of pixels: W x H) 2048x1536
  USB Signal output USB 2.0
  Color / Monochrome Color
  Sensor Size 1/2.5"
  Sensor Technology CMOS
  Sensor Type APTINA CMOS
  Rolling Shutter Yes
  Image Format 4/3
  Pixel Size (mm) 2.2x2.2
  Frame rate full resolution (fps) 8@1280x1024
  Frame rate other resolution (fps) 30@640x480
  Sensitivity 0.53 V/lux-second
  Signal/Noise Ratio (DB) 40.5
  Dynamic range (DB) 66.5
  ADC conversion 12 Bit
  Color Depth 8 Bit
  Exposure time … - 1.5 sec
  Binning 1x1
  IR filter Yes
  IR filter range (nm) 680
  Camera Power PC USB
  C-Mount Yes
Camera accessories Calibration slide Yes
Environment specifications Working Temperature -10°C up to +50°C
  Storage Temperature -20°C up to +60°C
  Relative Humidity 30% to 80%
  Storage Humidity 10% to 60%
Operating System OS Windows 10 (64Bit)
Available Software SW PROVIEW
Warranty Years 2
Tablet Operating system Windows 10 (64Bit)
  CPU Intel® Atom™ Z8350, Quad core
  CPU speed 1.44 GHz
  Graphic card Intel® HD Graphics 400
  RAM Ram 4 GB LPDDR3
  Display size LED 10.1” IPS Multi Touch Screen
  Display resolution 1920x1200
  Storage Hdd 64 GB
  Network Wireless - Bluetooth 4.0
  Input ports Micro USB (OTG) - USB Type-C - Micro SD card reader
  Output ports Microphone - Headphone - Micro HDMI
  Battery Type Lithium-ion
  Battery capacity 6500 mAh
  Power consumption 15W
  Power supply 5V 3A
  Dimensions (mm) 261X167X9
  Weight (Kg) 0.53
  Language Multilanguage
Tablet accessories OTG cable (micro USB-B to USB-A) Yes
  USB cable USB-B to USB-A (0.5m) Yes
  Touch pen Yes
 
Click Here To Download Catalogue
This is a 210g/0.001g Analytical electronic chemical balance for industrial and scientific field.
  • Specifications: 110g/0.001g, 210g/0.001g
  • Sensor’s Technology method: Strain gauge
  • Stainless steel pan size: ø90mm
  • Minimum weighing value: 0.003g
  • Resolution: 0.001g
  • Linearity: ±0.003g
  • Stabilization time: ≤ 2S
  • Sensitivity drift: ±0.003g
  • Weighing Units: g, oz, ct, mg
  • Operating Temperature: 17 C - 25  degree
  • Display Refresh time: 0.3 secs
  • External calibration weight free with scale: 100g, 200g
  • Counting feature: Yes
 
  • Display: LCD
  • Wind proof (shield) dimension: 170*190*170mm
  • Outlook size: 270*195*285mm
  • Operation Key: ON/OFF, COUNT, ENTER, CAL, UNIT
  • Power: AC 220V 50Hz
  • Main parts: Cast Aluminum, wind proof, Calibration weight
  • Optional part: RS232, Printer
 
  • Inner packing: 415*285*430mm
  • Outer packing:475*315*485mm
  • N.W.: 4kg
  • G.W.: 7kg
The linear and round stands have been designed to fit perfectly of TOPTION Pipette range, TopPette,MicroPette and MicroPette Plus Autoclavable Pipettes. The stands are convenient to hold up 6 pipettes both of single and multi-channel. Features:
  • Lightweight, fashion design
  • Can be rotating smoothly  comfortably hold up to 6 pipettes
  • Comfortably hold up to 6 pipettes
Technical Specifications:
Feature: Disposable
Application: Clinical, Household
Material: Plastic
Certification: CE
Group: Adult
Color: White and Gray
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare