Cryometrix B-90 Freezer

$0.00

Shipped From Abroad

The B-90 is a state-of-the-art liquid nitrogen blast freezer. Blast freezers are different from regular lab freezers in that they freeze the product placed within them much faster. The B-90 blast freezer can cool the payload bay from 20°C to -90°C in 5 minutes.

The B-90 blast freezes products with air frozen by liquid nitrogen. No nitrogen is exposed to products during this process, maintaining high product quality.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130146-11
Brands:: Mira Lab

Description

 

Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 738 kg 1626 lbs.
Payload Capacity 700 L 24.7 ft3
2mL Vial Capacity 48,000 48,000
Payload Dimensions (Depth x Width x Height) 578 mm x 800 mm x 1524 mm 22.76″ x 31.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 650 – 758 kPa 90 – 125 PSI
Adjustable Set Point 20°C to -90°C 68°F to -130°F
Temperature Uniformity 3°C ± at -90°C 5°F ± at -130°F
Cool Down Time 20°C to -80°C 7 min 7 min
Powerful Innovation
  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many blast freezers use metal plates to freeze product, severely limiting their use to thin and flat objects. Others inject LN2 directly into the payload bay, risking harmful exposure to the product.
    • The B-90 Blast Freezer uses liquid nitrogen in an efficient and powerful manner, allowing it to blast freeze anything that can fit inside it.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Greater Throughput
    • The increased capability of Cryometrix freezers allows faster turnaround times and thus greater profits.
Complete Safety
  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.

Reviews

There are no reviews yet.

Be the first to review “Cryometrix B-90 Freezer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCryometrix B-90 Freezer removeAutomatic Pipette removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeMotic BA210 Series Biomedical Microscope removeiSED Fully Automated ESR Analyzer remove
NameCryometrix B-90 Freezer removeAutomatic Pipette removeAlcohol Pad Per Pack removePlastic Urine Container Per Pack removeMotic BA210 Series Biomedical Microscope removeiSED Fully Automated ESR Analyzer remove
Image
SKUSF1033560130146-11SF1033560084-130SF1033560084-64SF1033560084-106SF1033560084-78SF1033560084-129
Rating
Price

$0.00

$0.00

$4.25

$8.20

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

The B-90 is a state-of-the-art liquid nitrogen blast freezer. Blast freezers are different from regular lab freezers in that they freeze the product placed within them much faster. The B-90 blast freezer can cool the payload bay from 20°C to -90°C in 5 minutes.

The B-90 blast freezes products with air frozen by liquid nitrogen. No nitrogen is exposed to products during this process, maintaining high product quality.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
 
Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 738 kg 1626 lbs.
Payload Capacity 700 L 24.7 ft3
2mL Vial Capacity 48,000 48,000
Payload Dimensions (Depth x Width x Height) 578 mm x 800 mm x 1524 mm 22.76″ x 31.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 650 – 758 kPa 90 – 125 PSI
Adjustable Set Point 20°C to -90°C 68°F to -130°F
Temperature Uniformity 3°C ± at -90°C 5°F ± at -130°F
Cool Down Time 20°C to -80°C 7 min 7 min
Powerful Innovation
  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many blast freezers use metal plates to freeze product, severely limiting their use to thin and flat objects. Others inject LN2 directly into the payload bay, risking harmful exposure to the product.
    • The B-90 Blast Freezer uses liquid nitrogen in an efficient and powerful manner, allowing it to blast freeze anything that can fit inside it.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Greater Throughput
    • The increased capability of Cryometrix freezers allows faster turnaround times and thus greater profits.
Complete Safety
  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare