New

Cryometrix B-90 Freezer

Ask for Price$0.00

Shipped From Abroad

The B-90 is a state-of-the-art liquid nitrogen blast freezer. Blast freezers are different from regular lab freezers in that they freeze the product placed within them much faster. The B-90 blast freezer can cool the payload bay from 20°C to -90°C in 5 minutes.

The B-90 blast freezes products with air frozen by liquid nitrogen. No nitrogen is exposed to products during this process, maintaining high product quality.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Mira Lab

Description

 

Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 738 kg 1626 lbs.
Payload Capacity 700 L 24.7 ft3
2mL Vial Capacity 48,000 48,000
Payload Dimensions (Depth x Width x Height) 578 mm x 800 mm x 1524 mm 22.76″ x 31.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 650 – 758 kPa 90 – 125 PSI
Adjustable Set Point 20°C to -90°C 68°F to -130°F
Temperature Uniformity 3°C ± at -90°C 5°F ± at -130°F
Cool Down Time 20°C to -80°C 7 min 7 min
Powerful Innovation
  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many blast freezers use metal plates to freeze product, severely limiting their use to thin and flat objects. Others inject LN2 directly into the payload bay, risking harmful exposure to the product.
    • The B-90 Blast Freezer uses liquid nitrogen in an efficient and powerful manner, allowing it to blast freeze anything that can fit inside it.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Greater Throughput
    • The increased capability of Cryometrix freezers allows faster turnaround times and thus greater profits.
Complete Safety
  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.

Reviews

There are no reviews yet.

Be the first to review “Cryometrix B-90 Freezer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Cryometrix B-90 Freezer removeZenithlab (IB-9025A) Laboratory Incubator removeiSED Fully Automated ESR Analyzer removeDiscover 5 Panel Cup with Adulterants Per Pack removeSugentech Inclix (POCT) Immunoassay Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameCryometrix B-90 Freezer removeZenithlab (IB-9025A) Laboratory Incubator removeiSED Fully Automated ESR Analyzer removeDiscover 5 Panel Cup with Adulterants Per Pack removeSugentech Inclix (POCT) Immunoassay Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageDrug Test Cup
SKUSF1033560084-109SF1033560084-129SF1033560084-23SF1033560084-89SF1033560060-2
Rating
Price

Ask for Price$0.00

$350.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

The B-90 is a state-of-the-art liquid nitrogen blast freezer. Blast freezers are different from regular lab freezers in that they freeze the product placed within them much faster. The B-90 blast freezer can cool the payload bay from 20°C to -90°C in 5 minutes.

The B-90 blast freezes products with air frozen by liquid nitrogen. No nitrogen is exposed to products during this process, maintaining high product quality.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
 
Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 738 kg 1626 lbs.
Payload Capacity 700 L 24.7 ft3
2mL Vial Capacity 48,000 48,000
Payload Dimensions (Depth x Width x Height) 578 mm x 800 mm x 1524 mm 22.76″ x 31.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 650 – 758 kPa 90 – 125 PSI
Adjustable Set Point 20°C to -90°C 68°F to -130°F
Temperature Uniformity 3°C ± at -90°C 5°F ± at -130°F
Cool Down Time 20°C to -80°C 7 min 7 min
Powerful Innovation
  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many blast freezers use metal plates to freeze product, severely limiting their use to thin and flat objects. Others inject LN2 directly into the payload bay, risking harmful exposure to the product.
    • The B-90 Blast Freezer uses liquid nitrogen in an efficient and powerful manner, allowing it to blast freeze anything that can fit inside it.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Greater Throughput
    • The increased capability of Cryometrix freezers allows faster turnaround times and thus greater profits.
Complete Safety
  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare