CU Medical Plasma Sterilizer HPS-100
$0.00
Shipped From Abroad
Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized
Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized.
Features:
Easy to install
Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system.
Easy to use
You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display.
Automatic notification system for regular maintenance
Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure.
Self-Test Features
When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety.
Validation of Sterilization of HPS?100
A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.
Specifications
Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge
Total Cycle Time :
1) Smart Mode – 40min
2) Standard Mode – 48min
3) Special Mode – 56min
Cycle Temperature : 45? ~ 60?
SAL(Sterility Assurance Level) : 10-6(Bacillus)
Material – Aluminum
Volume -100L
Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D)
Weight : 180?
Control : 32bit Micro Processor
Cycle Information : 2.7″(OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz
Power Consumption : Max 3.4kw
Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm
Placement : Bult-in wheels provide mobility
Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode/Detail Mode) Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
Click Here To Download Catalogue
Quick Comparison
Settings | CU Medical Plasma Sterilizer HPS-100 remove | Eppendorf Minispin Centrifuge remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Avalun LabPad Device remove | Avalun 48 INR Microcuvette remove | Skyla Hi POC Clinical Chemistry Analyzer remove | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | CU Medical Plasma Sterilizer HPS-100 remove | Eppendorf Minispin Centrifuge remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Avalun LabPad Device remove | Avalun 48 INR Microcuvette remove | Skyla Hi POC Clinical Chemistry Analyzer remove | ||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||
SKU | SF10335601245 | SF1033560084-116 | SF1033560060-1 | SF1033560084-65 | SF1033560084-74 | SF1033560060-2 | ||||||||||
Rating | ||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||
Stock | Out of stock | |||||||||||||||
Availability | Out of stock | |||||||||||||||
Add to cart | ||||||||||||||||
Description | Shipped From Abroad
Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||
Content | Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized.
Features:
Easy to install
Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system.
Easy to use
You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display.
Automatic notification system for regular maintenance
Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure.
Self-Test Features
When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety.
Validation of Sterilization of HPS?100
A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.
Specifications
Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge
Total Cycle Time :
1) Smart Mode – 40min
2) Standard Mode – 48min
3) Special Mode – 56min
Cycle Temperature : 45? ~ 60?
SAL(Sterility Assurance Level) : 10-6(Bacillus)
Material – Aluminum
Volume -100L
Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D)
Weight : 180?
Control : 32bit Micro Processor
Cycle Information : 2.7″(OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz
Power Consumption : Max 3.4kw
Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm
Placement : Bult-in wheels provide mobility
Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode/Detail Mode) Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
Click Here To Download Catalogue | Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue | The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
| skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| ||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Additional information |
Reviews
There are no reviews yet.