Description | Shipped From Abroad
Features:
- Wide AC input voltage range 85~265Vac.
- Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
- DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
- Ethernet power supply: one network cable can transmit data and electric
power at the same time.
- Over-charging, Over-discharging and Short Circuit protection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Intelligent CPU control
- Automatic power on when the the main power recovers
- Cold start function
- Power off charging function
- USB/RS232/RJ-11/RJ-45 communication port (optional)
- Offering LED and LCD panels for selection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Wide AC input voltage range 85~265Vac.
- Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
- DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
- Ethernet power supply: one network cable can transmit data and electric
power at the same time.
- Over-charging, Over-discharging and Short Circuit protection
Specifications
Model |
DC 1018P |
DC 1036P |
INPUT |
Input Voltage |
85 – 265Vac |
Output |
DC Output Voltage |
5V 2A |
5V 2A |
USB 2A |
USB 2A |
9V 1A |
9V 1A |
12V 1A |
12V 1A |
15V/24V(POE) 0.5A |
15V/24V(POE) 0.5A |
18W |
36W |
BATTERY |
Battery Type |
Lithium Battery |
Capacity of Battery |
2600mAh * 4 |
PROTECTION |
Protect |
Over-charging, Over-discharging and Short Circuit |
ENVIRNMENT |
Operation Temperature |
0°C – 40°C |
Noise Level |
Less than 40dB |
Dimension(mm) |
160 * 105 * 33 |
Net Weight(kg) |
0.40 |
0.42 |
| Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Technical Specifications
MODEL |
UPS-AP1K ( L ) |
UPS-AP2K ( L ) |
UPS-AP3K ( L ) |
Capacity |
1000VA/700W |
2000VA/1400W |
3000VA/2100W |
INPUT |
Voltage range |
145~275VAC±5V |
Frequency range |
50Hz-60Hz |
OUTPUT |
Output voltage |
220VAC |
AC voltage range |
±10% |
Frequency range(batt.mode) |
50Hz ± 0.25Hz or 60Hz ± 0.3Hz |
Overload |
105%-110%: UPS beep alarm, do not shut down. |
110%-130%: auto shut down after 30 seconds |
> 130%: auto shut down immediately |
Transfer time |
<typical 4ms |
Waveform(batt.mode) |
Pure sine wave |
BATTERY |
Standard model |
Battery type |
12V7Ah |
Numbers |
2 |
4 |
6 |
Charging current(Max.) |
Assume: 1A± 10%; Max: 1A or 2A for option |
Charging voltage |
27.3VDC±1% |
54.7VDC±1% |
82.0VDC±1% |
Long-run model |
Battery type |
12V, AH depending on applicant |
Numbers |
3 |
6 |
8 |
Charging current(Max.) |
> 5A |
Charging voltage |
27.4VDC±1% |
82.1VDC±1% |
109.4VDC±1% |
PHYSICAL |
Standard model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
11.9 |
22 |
27.9 |
Long-run model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
8.5 |
16 |
18.2 |
ENVIRONMENT |
Humidity |
20-90%RH @0-40°C (non-condensing) |
Noise level |
Less than 55dBA@1 Meter |
MANAGEMENT |
Smart RS-232 |
Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC |
Optional SNMP |
Power management from SNMP Management and web browser |
| Features:
- Intelligent CPU control
- Automatic power on when the the main power recovers
- Cold start function
- Power off charging function
- USB/RS232/RJ-11/RJ-45 communication port (optional)
- Offering LED and LCD panels for selection
Application:
- Personal Computer
- Printer
- POS(Point of sales)Terminals
- Security System
- Fax Machine
- Modem, WiFi Router
Technical Specifications:
Model |
DP600 |
DP1000 |
DP1200 |
DP2000 |
DP3000 |
Capacity |
600VA/360W |
1000VA/600W |
1200VA/720W |
2000VA/1200W |
3000VA/1800W |
INPUT |
Voltage |
110/120VAA or 220/230/240VAC |
Voltage Range |
67-137VAC/135-275VAC |
Frequency Range |
50Hz Or 60Hz(Auto-Sensing) |
OUTPUT |
Output Voltage |
110/120VAA or 220/230/240VAC |
AC Voltage Regulation |
± 10% |
Frequency Range
(Batt. Mode) |
50 HZ or 60 Hz ± 10% |
Transfer Time |
Typical 6-10 ms |
Waveform
(Battery Mode) |
Simulated Sine Wave |
BATTERY |
Battery Voltage |
12V/7AH*1 |
12V/9AH*1 |
12V/7AH*2 |
12V/9AH*2 |
12V/7AH*4 |
Charge Time |
8 hours up to 80-90% |
PROTECTION |
Full Protection |
Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection |
Communication Port |
USB/RS232/RJ11/RJ45 (Optional) |
Display |
LED/LCD |
Alarm |
Battery Mode |
Every 4 Seconds one beep |
Low Battery Capacity |
Every 1 Seconds one beep |
Overload |
Every 1 Seconds one beep |
Fault |
Keep beeping |
ENVIRONMENT |
Humidity |
0-90% Rh @ 0-40℃ (Non-Condensing) |
Noise Level |
40dB |
Dimension(mm) |
320*90*140 |
330* 100*150 |
365*140*165 |
365*140*165 |
395*145*210 |
N.W.(kg) |
5.2 |
6 |
10 |
12.6 |
21 |
| Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Specifications:
Model |
33VT 10K |
33VT 10KL |
33VT 20K |
33VT 20KL |
33VT 30KL |
33VT 40KL |
Capacity |
10KVA/9000W |
20KVA/18KW |
30KVA/27KW |
40KVA/36KW |
Input |
Nominal Voltage |
380/400/415Vac |
Voltage Range |
207-475VAC(3P4W+G) |
Current |
14A |
28A |
42A |
67A |
Frequency |
40-70Hz (Adjustable) |
Power Factor |
≥0.99 |
Output |
Voltage |
380VAC 1±1% (3P4W+G) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode) |
Current |
15A |
30A |
45A |
61A |
Power Factor |
0.9 |
Crest Factor |
3:1 |
THD |
Line load <3% |
Chrage Current |
5.5A |
1A |
7.5A |
1A |
5.5A |
Battery Nominal Voltage |
192VDC |
±192VDC |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
20%~95% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
710 |
560 |
Height (mm) |
717 |
501 |
717 |
717 |
Net Weight(Kg) |
26 |
72 |
57.5 |
98 |
58.5 |
62 |
| Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
Specifications
MODEL |
DX100KVA |
DX120KVA |
DX125KVA |
DX150KVA |
DX160KVA |
190KVA |
200KVA |
Rated Power |
80KW |
96KW |
100KW |
120KW |
128KW |
150KW |
160KW |
Peak Power(20ms) |
240KVA |
288KVA |
300KVA |
360KVA |
384KVA |
450KVA |
480KVA |
Start Motor |
40HP |
50HP |
50HP |
60HP |
60HP |
80HP |
80HP |
Battery Voltage |
384VDC |
Size(L*W*Hmm) |
875*720*1380 |
1123*900*1605 |
Packing Size(L*W*Hmm) |
980*825*1560 |
1185*960*1750 |
N.W.(kg) |
512 |
592 |
612 |
612 |
642 |
705 |
755 |
G.W.(kg)(Wooden Packing) |
552 |
632 |
652 |
652 |
692 |
755 |
805 |
INPUT |
DC Input Voltage Range |
10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
AC Input Frequency Range |
45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
Max AC charging current |
0-45A(Depending on the model) |
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
Phase |
3 PHASE |
OUTPUT |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
Output Frequency(Battery Mode) |
50/60Hz ±1% |
Output Wave(Battery Mode) |
Pure Sine Wave |
Output waveform distortion |
Linear load≤3% |
Efficiency(AC Mode) |
>99% |
Output Voltage(AC Mode) |
Conforming to AC input |
Output Frequency(AC Mode) |
Conforming to AC input |
No load loss(Battery Mode) |
≤1% rated power |
No load loss(AC Mode) |
≤2%rated power( charger does not work in AC mode) |
No load loss
(Energy saving Mode) |
≤10W |
Phase |
3 PHASE |
BATTERY |
VRLA Battery |
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements |
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
Protection |
Battery undervoltage alarm |
11V(Single battery voltage) |
Battery undervoltage protection |
10.5V(Single battery voltage) |
Battery overvoltage alarm |
15V(Single battery voltage) |
Battery overvoltage protection |
17V(Single battery voltage) |
Battery overvoltage recovery voltage |
14.5V(Single battery voltage) |
Overload power protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection |
>90°C(Shut down output) |
Alarm |
A |
Normal working condition, buzzer has no alarm sound |
B |
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C |
When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal |
Inside Solar controller |
Charging Mode |
MPPT or PWM |
(Optional) |
Charging current |
PWM: 100A-200A / MPPT: 50A/100A |
|
PV Input Voltage Range |
PWM: 480V-704V / MPPT: 480V-640V |
|
Max PV Input Voltage(Voc) |
PWM: 750V / MPPT: 800V |
|
(At the lowest temperature) |
|
PV Array Maximum Power |
PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A) |
|
Standby loss |
≤3W |
|
Maximum conversion efficiency |
>95% |
Working Mode |
Battery First/AC First/Saving Energy Mode |
Transfer Time |
≤4ms |
Display |
LCD |
Thermal method |
Forced Air Cooling |
Communication(Optional) |
RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment |
Operating temperature |
-10℃~40℃ |
Storage temperature |
-15℃~60℃ |
Noise |
2000m(More than derating) |
Elevation |
≤65dB |
Humidity |
0%~95% ,No condensation |
| Features:
- Capacity: 600W 512Wh /160000mAh
- Input AC Output Power:Rated Power 600W Peak Power 1200W
- Input AC Charging:AC100~120V/AC200~240V Built-in 200W
- Input Car Charging:DC12V~24V/7A Max 120W Max
- Input Solar Charging:DC12V~24V/120WMax
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC24W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
|
Reviews
There are no reviews yet.