DC UPS with POE Port 45W/60/100/120W with Lithium Battery

$0.00

Shipped From Abroad

Features:
  • Compact Size with nice housing case design. Stable performance with strong compatibility.
  • Built-in adapter, wide input, voltage range (100-240VAC).
  • Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
  • Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
  • 100W has 19VDC output, it can be used for desktop computer / laptop computer.
  • 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
  • Customize various of plugs and DC interfaces.
  • LCD indicator display design for monitor the working status easier.
  • Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-7
Brands:: Reeco Power

Description

Features:
  • Compact Size with nice housing case design. Stable performance with strong compatibility.
  • Built-in adapter, wide input, voltage range (100-240VAC).
  • Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
  • Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
  • 100W has 19VDC output, it can be used for desktop computer / laptop computer.
  • 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
  • Customize various of plugs and DC interfaces.
  • LCD indicator display design for monitor the working status easier.
  • Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection

 

Specifications
Model DCP-45W DCP-60W DCP-100W DCP-120W
Input voltage 100-240Vac/50-60Hz
12-24Vdc (2.5A Max)
1*9/12V(2A) (selectable)
Output voltage 4*12V(3.5A) Standard: 4*12V(5A)

Customized: 3*12V(5A)+1*19V(3A)

Standard: 4*12V(8A)

Customized: 3*12V(8A)+1*19V(5A)

Standard: 4*12V(10A)

Customized: 3*12V(10A)+1*19V(6A)

1*5VDC+2*USB (2.4A)
Standard:

1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)

Customized:

1)2*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)

2)1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)+1*15V(1.5A)/24V(1A) POE(Selectable)

3)2*15V(1.5A)/24V(1A) POE(Selectable)

Efficiency AC mode:>85%,Battery mode:>90%
battery size 18650/21700/32700 18650/21700/32700 18650/21700/32700 18650/21700/32700
battery type Lithium-ion battery/LiFePO4 battery
battery capacity 8000-20800mah 8000-48000mah 8000-48000mah 8000-48000mah
battery numbers 4/8 4/8 4/8 4/8
Material ABS
protection function Over-charge, Over-discharge, Over-current, overload, over-temperature,short circuit
operating Temperature 0℃~40℃
Storage Temperature -10℃-50℃
humidity 10%-90%RH
altitude <3000m
Noise level <45db
Product Dimensions 180*130*64mm 214*158.5*86mm 214*158.5*86mm 214*158.5*86mm
package size 196*202*73mm 230*230*95mm 230*230*95mm 230*230*95mm
Net weight 1.27(max) 1.85kg(max)   1.88kg(max)   1.9kg(max)
Gross weight 1.32(max) 2.6kg(max)   2.63kg(max)   2.65kg(max)

Reviews

There are no reviews yet.

Be the first to review “DC UPS with POE Port 45W/60/100/120W with Lithium Battery”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDC UPS with POE Port 45W/60/100/120W with Lithium Battery removeLine Interactive UPS DP Series 600VA-3000VA remove3 Phase Low Frequency Online UPS LF33 Series remove3 Phase Low Frequency Solar Inverter DX Series removeOPzV Tubular Gel Battery 60AH-3000AH removeSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA remove
NameDC UPS with POE Port 45W/60/100/120W with Lithium Battery removeLine Interactive UPS DP Series 600VA-3000VA remove3 Phase Low Frequency Online UPS LF33 Series remove3 Phase Low Frequency Solar Inverter DX Series removeOPzV Tubular Gel Battery 60AH-3000AH removeSingle Phase High Frequency Online UPS VT Series 1KVA-3KVA remove
Image
SKUSF1033560130139-7SF1033560130139-17SF1033560130139-4SF1033560130139-5SF1033560130139-18SF1033560130139-25
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Features:
  • Compact Size with nice housing case design. Stable performance with strong compatibility.
  • Built-in adapter, wide input, voltage range (100-240VAC).
  • Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
  • Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
  • 100W has 19VDC output, it can be used for desktop computer / laptop computer.
  • 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
  • Customize various of plugs and DC interfaces.
  • LCD indicator display design for monitor the working status easier.
  • Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Compact Size with nice housing case design. Stable performance with strong compatibility.
  • Built-in adapter, wide input, voltage range (100-240VAC).
  • Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
  • Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
  • 100W has 19VDC output, it can be used for desktop computer / laptop computer.
  • 60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
  • Customize various of plugs and DC interfaces.
  • LCD indicator display design for monitor the working status easier.
  • Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
 
Specifications
Model DCP-45W DCP-60W DCP-100W DCP-120W
Input voltage 100-240Vac/50-60Hz
12-24Vdc (2.5A Max)
1*9/12V(2A) (selectable)
Output voltage 4*12V(3.5A) Standard: 4*12V(5A) Customized: 3*12V(5A)+1*19V(3A) Standard: 4*12V(8A) Customized: 3*12V(8A)+1*19V(5A) Standard: 4*12V(10A) Customized: 3*12V(10A)+1*19V(6A)
1*5VDC+2*USB (2.4A)
Standard: 1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable) Customized: 1)2*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable) 2)1*24(1.2A) /48V(0.6A)(POE 1 Gbps) (Selectable)+1*15V(1.5A)/24V(1A) POE(Selectable) 3)2*15V(1.5A)/24V(1A) POE(Selectable)
Efficiency AC mode:>85%,Battery mode:>90%
battery size 18650/21700/32700 18650/21700/32700 18650/21700/32700 18650/21700/32700
battery type Lithium-ion battery/LiFePO4 battery
battery capacity 8000-20800mah 8000-48000mah 8000-48000mah 8000-48000mah
battery numbers 4/8 4/8 4/8 4/8
Material ABS
protection function Over-charge, Over-discharge, Over-current, overload, over-temperature,short circuit
operating Temperature 0℃~40℃
Storage Temperature -10℃-50℃
humidity 10%-90%RH
altitude <3000m
Noise level <45db
Product Dimensions 180*130*64mm 214*158.5*86mm 214*158.5*86mm 214*158.5*86mm
package size 196*202*73mm 230*230*95mm 230*230*95mm 230*230*95mm
Net weight 1.27(max) 1.85kg(max)   1.88kg(max)   1.9kg(max)
Gross weight 1.32(max) 2.6kg(max)   2.63kg(max)   2.65kg(max)
Features:
  • Intelligent CPU control
  • Automatic power on when the the main power recovers
  • Cold start function
  • Power off charging function
  • USB/RS232/RJ-11/RJ-45 communication port (optional)
  • Offering LED and LCD panels for selection
 
Application:
  • Personal Computer
  • Printer
  • POS(Point of sales)Terminals
  • Security System
  • Fax Machine
  • Modem, WiFi Router
 
Technical Specifications:
 
Model DP600 DP1000 DP1200 DP2000 DP3000
Capacity 600VA/360W 1000VA/600W 1200VA/720W 2000VA/1200W 3000VA/1800W
INPUT
Voltage 110/120VAA or 220/230/240VAC
Voltage Range 67-137VAC/135-275VAC
Frequency Range 50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage 110/120VAA or 220/230/240VAC
AC Voltage Regulation ± 10%
Frequency Range (Batt. Mode) 50 HZ or 60 Hz ± 10%
Transfer Time Typical 6-10 ms
Waveform (Battery Mode) Simulated Sine Wave
BATTERY
Battery Voltage 12V/7AH*1 12V/9AH*1 12V/7AH*2 12V/9AH*2 12V/7AH*4
Charge Time 8 hours up to 80-90%
PROTECTION
Full Protection Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
 Communication Port USB/RS232/RJ11/RJ45  (Optional)
Display LED/LCD
          Alarm
Battery Mode Every 4 Seconds one beep
Low Battery Capacity Every 1 Seconds one beep
Overload Every 1 Seconds one beep
Fault Keep beeping
ENVIRONMENT
Humidity 0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level 40dB
Dimension(mm) 320*90*140 330* 100*150 365*140*165 365*140*165 395*145*210
N.W.(kg) 5.2 6 10 12.6 21
Features:
  • Optional 7 ” touch LCD
  • Online double-conversionDSP technology guarantees high reliability
  • True galvanic isolation transformer designControl designed to withstand all kinds of loads
  • Intelligent battery management to prolong battery lifecycle
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment
  • Adiustable battery numbers
  • Accept dual-mains input
  • Parallel operation with up to 4 units ( option )
  • Variety of communication options available
  • Reverse phase frequency operation and supportsnon-neutral input
 
Specifications
MODEL LF33 10K LF33 20K LF33 30K LF33 40K LF33  60K LF33  80K LF33 100K LF33 120K LF33 160K LF33 200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hzor56-64Hz
INVERTER
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement 120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time Restore to 90% of rated value in 3 cycles
Overload capacity 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load                    <1%
Current Limit High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm) 656 x 405 x 817 656 x 405 x 941 840x432x1140 975x554x1286 1200x910x1680 1500x1140x1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
Features:
  • OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
  • Voltage class: 12V/2V
  • Capacity range: 60Ah~3000Ah

OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation, OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere, even in remote environments with minimal supervision.

 
Technical Specifications
Model Nominal Voltage Capacity Dimension Terminal
C10/1.80VPC (Ah) Length Width Height Total Height
(V) mm mm mm mm
OPzV6-200 6 200 322 177.5 226 231 F16(M8) F14(M8)
OPzV12-60 12 60 260 169 211 216  F11(M6)
OPzV12-80 12 80 328 172 215 220  F12(M8)
OPzV12-100 12 100 407 177 225 225  F12(M8)
OPzV12-120 12 120 483 170 241 241  F12(M8)
OPzV12-140 12 140 532 207 214 219  F12(M8)
OPzV12-160 12 160 532 207 214 219 F12(M8)
OPzV12-180 12 180 522 240 219 224  F10(M8)
OPzV12-200 12 200 521 268 220 225 F14(M8)
OPzV2-200 2 200 103 206 355 390 F10(M8)
OPzV2-250 2 250 124 206 355 390 F10(M8)
OPzV2-300 2 300 145 206 355 390 F10(M8)
OPzV2-350 2 350 124 206 470 505 F10(M8)
OPzV2-420 2 420 145 206 470 505 F10(M8)
OPzV2-500 2 490 166 206 470 505 F10(M8)
OPzV2-770 2 770 210 254 470 505 F10(M8)
OPzV2-600 2 600 145 206 645 680 F10(M8)
OPzV2-800 2 800 191 210 645 680 F10(M8)
OPzV2-1000 2 1000 233 210 645 680 F10(M8)
OPzV2-1200 2 1200 276 210 645 680 F10(M8)
OPzV2-1500 2 1500 275 210 795 830 F10(M8)
OPzV2-2000 2 2000 399 214 770 805 F10(M8)
OPzV2-2500 2 2500 487 212 770 805 F10(M8)
OPzV2-3000 2 3000 576 212 770 805 F10(M8)
Features:
  • True Double conversion Technology
  • DSP digital control technology enable UPS more stable performance.
  • Three-level inverter technology
  • Active High input power factor correction technology (PFC)
  • Wide Input Voltage Frequency Range& Strong load capacity
  • Zero power switch delay
  • Compatible with Generators
  • Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
  • Support intelligent monitoring
  • Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
 
Technical Specifications
Model VT1K VT1KL VT2K VT2KL VT3K VT3KL
Rated power 1KVA/900KW 2KVA/1.8KW 3KVA/2.7KW
Input Voltage range 90~285Vac L+N+G
Frequency range 40-70Hz(Adjustable)
Input power factor >0.99
Output Rated voltage and precision 220Vac (1±2% ) L+N+G
Output frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current 4.5A 9.1A 13.6A
Output power factor 0.9
Output harmonic ≤4%
Crest factor 3:1
Inverter overload capacity 105%±5%< Load<125%±5% : 50s transfer to bypass 125% ±5% < Load<150 % ±5 % : 25s transfer to bypass Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time 0ms
Efficiency ≥85%
Battery Rated voltage 24Vdc 36Vdc 48Vdc 72Vdc 72Vdc 96Vdc
Battery Numbers 2 3 4 6 6 8
Charge current 1A 6.5A 1A 5.5A 1A 5.5A
Size(LXWXH)mm 350*144*230 425*190*328
Net Weight(KG) 9.5kg 6kg 18.5kg 10kg 23.5kg 11kg
Operating temperature 0°C 〜40°C
Operating humidity 20% 〜95%
Noise ≤50dB
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare