Disposable ECG Monitoring Electrode

$0.00

Shipped From Abroad

Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-24
Brands:: OBS

Description

Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured).

2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact.

3. Tear off the release film from the bottom (the part away from metal stud) of electrode.

4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly.

Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.

Reviews

There are no reviews yet.

Be the first to review “Disposable ECG Monitoring Electrode”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDisposable ECG Monitoring Electrode removeElectrotherapy Electrode with Cables removeOBS-100C(II) Cold RF Unit removeOBS-100B Cold Bipolar Coagulator removeElectrosurgical Pad removeSS-100 Smoke Evacuation System remove
NameDisposable ECG Monitoring Electrode removeElectrotherapy Electrode with Cables removeOBS-100C(II) Cold RF Unit removeOBS-100B Cold Bipolar Coagulator removeElectrosurgical Pad removeSS-100 Smoke Evacuation System remove
Image
SKUSF1033560130165-24SF1033560130165-23SF1033560130165-6SF1033560130165-8SF1033560130165-16SF1033560130165-9
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad OBS-100C(II) uses high-frequency radio wave technology as an energy source to cut and coagulate soft tissue. it operates at 3.8MHz, enabling a precise incision with significantly less heat and resultant heat damage than typically found with conventional electrosurgery. Since tissue stays cooler with high-frequency radio wave technology, you can feel confident that you are minimizing cellular destruction along the incision path.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The OBS-100B Cold Bipolar Coagulator is a precision electrosurgical device designed for delicate surgeries. It ensures minimal tissue irritation, offers a non-stick effect, and operates without sparking, making it ideal for microsurgical applications like neurosurgery and ophthalmology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Electrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient's body, ensuring the safety and effective operation of the electrosurgical unit (ESU)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentIndications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
Electrotherapy electrodes with cables are used to connect the electrodes to the electrotherapy device, allowing electrical currents to be delivered to the targeted area. These cables typically have a standard 2mm pin connector that plugs into the device and the electrodes. There are different types of cables available, such as:
  • Standard Lead Wires: These are the basic cables that come with most electrotherapy units.
  • Bifurcation Cables: These cables allow you to connect multiple electrodes to a single channel, effectively doubling the number of electrodes you can use.
  • Extended Length Cables: These are longer cables that provide more flexibility in positioning the electrodes.
 
Features
  • Low voltage output: Ensures minimal irritation to neuromuscular tissues.
  • Sparkless operation: Reduces tissue sticking.
  • Superb non-stick effect: Enhances surgical precision.
  • Suitable for microsurgery: Ideal for neurosurgery, ophthalmology, gynecology, and plastic surgery
 
 
Features:
  1. High Conductivity: They are made from materials that ensure efficient conduction of electrical current.
  2. Large Surface Area: This helps in dispersing the current over a wide area, reducing the risk of burns.
  3. Adhesive Backing: They usually have an adhesive side to securely attach to the patient's skin.
  4. Flexible Design: They are designed to conform to the contours of the patient's body.
  5. Safety Mechanisms: Modern pads often include features like dual-pad return electrodes for fail-safe operation.
Uses:
  1. Completing the Electrical Circuit: They act as a return path for the electrical current used in electrosurgery.
  2. Minimizing Burns: By dispersing the current, they help prevent burns at the surgical site.
  3. Ensuring Patient Safety: They are crucial for the safe operation of electrosurgical units, especially in patients with electronic implants like pacemakers.
  4. Versatile Applications: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare