Ducted Fume Hood

$0.00

Shipped From Abroad

FMH (A) series ducted fume hood is designed as a negative pressure ventilation system that ensures the safety of operators and the laboratory environment. It works by drawing room air inward through the front opening of the hood and continuously ventilating it with an extraction blower. This prevents the spread of contaminated fumes, vapors, toxic gases, aerosols, and corrosive substances that may be generated during experiments. Furthermore, an optional active carbon filter can purify the polluted air before it is exhausted through the duct, thereby protecting the outdoor environment as well.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-39
Brands:: Scitek

Description

Ducted Fume Hood Features:
  1. UV lamp for sterilization.
  2. Resistant to weak acid and alkali.
  3. Adjustable air speed: 3 levels.
  4. Manual or motorized front window, height adjustable.
  5. Microprocessor control system, LCD display.
  6. With memory function in case of power-failure.
  7. New design, with a liquid collection tank behind the backpanel to collect the waste liquid generated during the experiment and reduce pollution.
  8. Front panel with bypass Grille, Sash air foil and bypass system achieve function of Air supplement. Meets North American fume hood design standards.

 

Product Data
  • External Size : 3ft / 4ft / 5ft / 6ft
  • Maximum Opening : 520mm
  • Work Surface Height : 850mm
  • Airflow Velocity : Adjustable 0.3~0.8 m/s
  • Exhaust Duct : Φ300mm PVC (Standard Length: 10 meters)

 

Ducted Fume Hood Specifications:
Model FMH-1000DA FMH-1200DA FMH-1500DA FMH-1800DA
FMH-1000DA(II) FMH-1200DA(II) FMH-1500DA(II) FMH-1800DA(II)
External Size (WxDxH)(mm) 1040x800x2200 1240x800x2200 1540x800x2200 1840x800x2200
Internal Size (WxDxH)(mm) 820x670x730 1020x670x730 1320x670x730 1620x670x730
Front Window Manual (FMH-DA series),  Motorized (FMH-DA(II) series) 5mm toughened glass; Height adjustable.
Work Surface Height 850mm
Max Opening 520mm
Air Velocity 0.3~0.8m/s
Sound Emission ≤68dB
Exhaust Duct PVC, Standard Length: 10 meters.
Φ300mm
LED Lamp 8Wx1 12Wx1 16Wx1 16Wx1
UV Lamp Emission of 253.7 nanometers for most efficient decontamination
Blower Built-in centrifugal blower; Speed adjustable.
Power Supply AC220±10%, 50/60Hz; 110V±10%, 60Hz
Consumption 400W 400W 500W 500W
Material Exterior Cold-rolled steel with anti-bacteria powder coating.
Interior Compact laminate board with good acid and alkali resistance function
Work Table Chemical resistant phenolic resin
Standard Accessories UV lamp x2, LED lamp, Water tap, Gas tap, Water sink, Base cabinet, 2pc waterproof sockets, Water supply flow control valve, Gas supply flow control valve
Total load of 2 waterproof sockets: 500W
10m PVC aluminum foil composite exhaust duct, pipe strap x2 (Duct is retractable and can be cut freely)
Optional Accessories Active carbon filter/HEPA filter
Gross Weight 286kg 317kg 350kg 400kg
Shipping Size (WxDxH)(mm) Main Body 1190x990x1690 1390x990x1690 1690x990x1690 1990x990x1690
Base Cabinet 1190x990x900 1390x990x900 1690x990x900 1990x990x900
Shipping Volume 3.1m³ 3.6m³ 4.3m³ 5.1m³

Reviews

There are no reviews yet.

Be the first to review “Ducted Fume Hood”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDucted Fume Hood removeZenithlab (IB-9025A) Laboratory Incubator removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removePlastic Urine Container Per Pack remove8 Bucket Centrifuge removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameDucted Fume Hood removeZenithlab (IB-9025A) Laboratory Incubator removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removePlastic Urine Container Per Pack remove8 Bucket Centrifuge removeAGD Erma EL-120 ELectrolyte Analyzer remove
Image
SKUSF1033560130127-39SF1033560084-109SF1033560060-1SF1033560084-106SF1033560084-114SF1033560084-125
Rating
Price

$0.00

$350.00

$0.00

$8.20

$72.50

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad FMH (A) series ducted fume hood is designed as a negative pressure ventilation system that ensures the safety of operators and the laboratory environment. It works by drawing room air inward through the front opening of the hood and continuously ventilating it with an extraction blower. This prevents the spread of contaminated fumes, vapors, toxic gases, aerosols, and corrosive substances that may be generated during experiments. Furthermore, an optional active carbon filter can purify the polluted air before it is exhausted through the duct, thereby protecting the outdoor environment as well.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Ducted Fume Hood Features:
  1. UV lamp for sterilization.
  2. Resistant to weak acid and alkali.
  3. Adjustable air speed: 3 levels.
  4. Manual or motorized front window, height adjustable.
  5. Microprocessor control system, LCD display.
  6. With memory function in case of power-failure.
  7. New design, with a liquid collection tank behind the backpanel to collect the waste liquid generated during the experiment and reduce pollution.
  8. Front panel with bypass Grille, Sash air foil and bypass system achieve function of Air supplement. Meets North American fume hood design standards.
 
Product Data
  • External Size : 3ft / 4ft / 5ft / 6ft
  • Maximum Opening : 520mm
  • Work Surface Height : 850mm
  • Airflow Velocity : Adjustable 0.3~0.8 m/s
  • Exhaust Duct : Φ300mm PVC (Standard Length: 10 meters)
 
Ducted Fume Hood Specifications:
Model FMH-1000DA FMH-1200DA FMH-1500DA FMH-1800DA
FMH-1000DA(II) FMH-1200DA(II) FMH-1500DA(II) FMH-1800DA(II)
External Size (WxDxH)(mm) 1040x800x2200 1240x800x2200 1540x800x2200 1840x800x2200
Internal Size (WxDxH)(mm) 820x670x730 1020x670x730 1320x670x730 1620x670x730
Front Window Manual (FMH-DA series),  Motorized (FMH-DA(II) series) 5mm toughened glass; Height adjustable.
Work Surface Height 850mm
Max Opening 520mm
Air Velocity 0.3~0.8m/s
Sound Emission ≤68dB
Exhaust Duct PVC, Standard Length: 10 meters.
Φ300mm
LED Lamp 8Wx1 12Wx1 16Wx1 16Wx1
UV Lamp Emission of 253.7 nanometers for most efficient decontamination
Blower Built-in centrifugal blower; Speed adjustable.
Power Supply AC220±10%, 50/60Hz; 110V±10%, 60Hz
Consumption 400W 400W 500W 500W
Material Exterior Cold-rolled steel with anti-bacteria powder coating.
Interior Compact laminate board with good acid and alkali resistance function
Work Table Chemical resistant phenolic resin
Standard Accessories UV lamp x2, LED lamp, Water tap, Gas tap, Water sink, Base cabinet, 2pc waterproof sockets, Water supply flow control valve, Gas supply flow control valve
Total load of 2 waterproof sockets: 500W
10m PVC aluminum foil composite exhaust duct, pipe strap x2 (Duct is retractable and can be cut freely)
Optional Accessories Active carbon filter/HEPA filter
Gross Weight 286kg 317kg 350kg 400kg
Shipping Size (WxDxH)(mm) Main Body 1190x990x1690 1390x990x1690 1690x990x1690 1990x990x1690
Base Cabinet 1190x990x900 1390x990x900 1690x990x900 1990x990x900
Shipping Volume 3.1m³ 3.6m³ 4.3m³ 5.1m³
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare