DynaMesh-HIATUS

$0.00

Shipped From Abroad

DynaMesh®-HIATUS implants are intended for the surgical treatment of axial and/or paraoesophageal hiatal hernias, if a high risk of recurrence is expected with hiatoplasty using a simple suture technique. The devices permanently reinforce the soft tissue of the diaphragm in the region of the oesophageal hiatus.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-7
Brands:: Dyna Mesh

Description

Defined Stability
Constriction of the mesh in the region of the hiatus may reduce the distance between the mesh implant and the oesophagus. DynaMesh®-HIATUS implants have rectangular pores and defined stability with a maximum elongation of only 8% [TR50, TR51].

 

hiatus-vergleich

 

Effective Porosity
All DynaMesh®-HIATUS implants have an effective porosity [TR51]. DynaMesh®-HIATUS implants are made of PVDF. PVDF has good biocompatibility, reducing the foreign body reaction compared to other materials such as polypropylene [1A, 2A, 4A, 68A, 100A, TR1].
DynaMesh®-HIATUS implants show little mesh shrinkage [51].

 

hiatus-porositaet

 

 

 

Smooth Warp-Knitted Selvedges
All DynaMesh®-HIATUS implants have smooth warp-knitted
selvedges.

 

 

 

hiatus-atraumatische-kanten

 

Specifications
Product DynaMesh®-HIATUS
Surgical Treatment Hiatal Hernias
Surgical Approach Minimally Invasive / Open
Surgical Technique Cruroplasty with mesh reinforcement
Fixation  Suture* / Tissue Adhesives / Tacks*
Defined Stability
gruene_punkte[TR50]
Smooth Warp-Knitted Selvedges
gruene_punkte
Visible Technology
gruene_punkte
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103p, TR51]
Klinge’s Mesh Classification Class 1a  [102P, TR51]
* Traumatic fixation may only be used if injuries to the pericardium, aorta or vena cava can be ruled out with total certainty.

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-HIATUS”

Your email address will not be published. Required fields are marked *

Quick Comparison

DynaMesh-HIATUS removeAmbu Bag with Reservior removeOxygen Concentrator 3Ltr. removeDe Lineb Oxygen Face Mask removeElastomeric Pump (Disposable Infusion Pump) with PCA removePortable Stainless Steel Autoclave Sterilizer remove
NameDynaMesh-HIATUS removeAmbu Bag with Reservior removeOxygen Concentrator 3Ltr. removeDe Lineb Oxygen Face Mask removeElastomeric Pump (Disposable Infusion Pump) with PCA removePortable Stainless Steel Autoclave Sterilizer remove
Image
SKUSF1033560130161-7SF1033560084-41SF1033560084-40SF1033560084-39SF1033560084-18SF1033560084-4
Rating
Price

$0.00

$17.00

$273.00

$1.40

$0.00

$216.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad DynaMesh®-HIATUS implants are intended for the surgical treatment of axial and/or paraoesophageal hiatal hernias, if a high risk of recurrence is expected with hiatoplasty using a simple suture technique. The devices permanently reinforce the soft tissue of the diaphragm in the region of the oesophageal hiatus.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Defined Stability Constriction of the mesh in the region of the hiatus may reduce the distance between the mesh implant and the oesophagus. DynaMesh®-HIATUS implants have rectangular pores and defined stability with a maximum elongation of only 8% [TR50, TR51].  

hiatus-vergleich

  Effective Porosity All DynaMesh®-HIATUS implants have an effective porosity [TR51]. DynaMesh®-HIATUS implants are made of PVDF. PVDF has good biocompatibility, reducing the foreign body reaction compared to other materials such as polypropylene [1A, 2A, 4A, 68A, 100A, TR1]. DynaMesh®-HIATUS implants show little mesh shrinkage [51].  
hiatus-porositaet
      Smooth Warp-Knitted Selvedges All DynaMesh®-HIATUS implants have smooth warp-knitted selvedges.      
hiatus-atraumatische-kanten  
Specifications
Product DynaMesh®-HIATUS
Surgical Treatment Hiatal Hernias
Surgical Approach Minimally Invasive / Open
Surgical Technique Cruroplasty with mesh reinforcement
Fixation  Suture* / Tissue Adhesives / Tacks*
Defined Stability
gruene_punkte[TR50]
Smooth Warp-Knitted Selvedges
gruene_punkte
Visible Technology
gruene_punkte
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)
Polymer (Monofilament) PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103p, TR51]
Klinge’s Mesh Classification Class 1a  [102P, TR51]
* Traumatic fixation may only be used if injuries to the pericardium, aorta or vena cava can be ruled out with total certainty.

Click here to download Catalogue

Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
  • Brand: OEM
  • Item No.: AM-DMR-M06-0/1/4
  • Color: Green
  • Size: Adult/Pediatric/Infant
  • Material: Disposable
  • Application: Emergency Resuscitation
  • MOQ: 300
  • Lead Time: 60 days
  • Shipping Terms: FOB
  • Packaging Details: Each set is packed into a white PP box
  • Carton Size: 57 x 34 x 46 CM / 12 SETS
  • Shipping Weight: 9.8 Kilos
  Technical Specifications:
Type Infant Pediatric Adult
Patient weight ≤10kg 10kg-40kg >40kg
Stroke volume 150ml 400ml 800ml
Resuscitator volume 280ml 600ml 1650ml
Dimensions L x D 135 x 75mm 146 x 100mm 212 x 131mm
Resuscitator weight 350g 410g 600g
Pressure limiting valve 40cmH2O 40cmH2O 60cmH2O
Inspiratory resistance <5cmH2O (at 50L/min)
Expiratory resistance <5cmH2O (at 50L/min)
Bag volume 1600ml 1600ml 2000ml
Patient connector ISO5356-1:φ22/15mm Male/Female
Recommended operating temperature -18℃~+50℃
Storage Tested at -40℃ and 60℃
 
 
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
Features:
  • Non-toxic PVC
  • Medium concentration
  • Adjustable nose clip
  • Non-Autoclavable
  • Available size: adult, child
  Technical Specifications:
  • Product Name: Oxygen Mask
  • Material: Medical grade PVC
  • Color: Green
  • Size: S, M, L, L , XL
  • Package: PE bag
  • Tube size: 2m
  • Nose Clip: adjustable
  • Disposable Medical Oxygen Face Mask Types MSLMK01
 
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.Features:
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: YX280A
Sterilizing volume 18L
Working pressure 0.14-0.16Mpa
Working temperature 126ºC
Max. safety pressure 0.165Mpa
Characteristics Electric heated
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare