DynaMesh-IPOM

$0.00

Shipped From Abroad

DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the treatment of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-4
Brands:: Dyna Mesh

Description

DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are primarily made of polyvinylidene fluoride (PVDF).
The mesh implants are warp-knitted using coloured and uncoloured polyvinylidene fluoride (PVDF) monofilaments and uncoloured polypropylene (PP) monofilaments.

 

Positioning
DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by the green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

The mesh implant must be placed in such a way that the green filament ends are always oriented towards the abdominal wall. At the same time, the mesh implant must be oriented so that the green filament ends are cranial or caudal.

 

DM-IPOM_intraoperativei

Intraoperative view

 

Specifications
Product DynaMesh®-IPOM (1)
DynaMesh®-IPOM visible (2)
Surgical Treatment Umbilical Hernias / Epigastric Hernias /
Incisional Hernias / Parastomal Hernias
Surgical Approach Minimally Invasive / Open
Mesh Position Intraperitoneal* according to the intraperitoneal onlay mesh technique (IPOM).
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends gruene_punkte
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) (2)
– Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) (2)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)  (2)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Tear Propagation Resistance
gruene_punkte[TR62]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR64]
Klinge’s Mesh Classification Class 1a [102P, TR64]
* In particular cases with an extraperitoneal mesh position in which there is a risk of contact between the mesh implant and the intestine, the device may also be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-IPOM”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDynaMesh-IPOM removeElastomeric Pump (Disposable Infusion Pump) with PCA removeAmbu Oval Silicone resuscitator (Ambu Bag) removeBettermed BT666EPZ Multi-function Electric Delivery Bed removeLittmann Classic III Stethoscope removeLittman Stethoscope remove
NameDynaMesh-IPOM removeElastomeric Pump (Disposable Infusion Pump) with PCA removeAmbu Oval Silicone resuscitator (Ambu Bag) removeBettermed BT666EPZ Multi-function Electric Delivery Bed removeLittmann Classic III Stethoscope removeLittman Stethoscope remove
ImageLittmann Classic III StethoscopeLittman Stethoscope
SKUSF1033560130161-4SF1033560084-18SF1033560084-62SF1033560084-51SF1033560084-34SF1033560084-5
Rating
Price

$0.00

$0.00

$27.00

$2,024.00

$34.00

$13.20

Stock

In stock

AvailabilityIn stock
Add to cart

DescriptionShipped From Abroad DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are intended for the surgical treatment of epigastric hernias, umbilical or incisional hernias, and the treatment of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the abdominal wall defect.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Function:Backrest tilting From 0°to 75° ±5° Hi-lo function Reverse:14°±1° Trendelenburg:12°±1°

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
DynaMesh®-IPOM and DynaMesh®-IPOM visible implants are primarily made of polyvinylidene fluoride (PVDF). The mesh implants are warp-knitted using coloured and uncoloured polyvinylidene fluoride (PVDF) monofilaments and uncoloured polypropylene (PP) monofilaments.   Positioning DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by the green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface. The mesh implant must be placed in such a way that the green filament ends are always oriented towards the abdominal wall. At the same time, the mesh implant must be oriented so that the green filament ends are cranial or caudal.  

DM-IPOM_intraoperativei

Intraoperative view

 
Specifications
Product DynaMesh®-IPOM (1) DynaMesh®-IPOM visible (2)
Surgical Treatment Umbilical Hernias / Epigastric Hernias / Incisional Hernias / Parastomal Hernias
Surgical Approach Minimally Invasive / Open
Mesh Position Intraperitoneal* according to the intraperitoneal onlay mesh technique (IPOM).
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends gruene_punkte
Visible Technology graue_punkte (1) / gruene_punkte (2)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) (2) – Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) (2) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w)  (2)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Tear Propagation Resistance
gruene_punkte[TR62]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR64]
Klinge’s Mesh Classification Class 1a [102P, TR64]
* In particular cases with an extraperitoneal mesh position in which there is a risk of contact between the mesh implant and the intestine, the device may also be placed extraperitoneally in onlay, sublay and/or preperitoneal mesh position.
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests
DynaMesh®-IPOM and DynaMesh®-IPOM visible implants have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

Click here to download Catalogue

This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Features
  • The Ambu Oval Silicone resuscitator has a special textured surface combined with the unique support strap to ensures that a comfortable and firm grip is guaranteed, allowing for effective ventilation over extended periods, without the problem of hand fatigue.
  • The Ambu Oval Silicone Resuscitators is made out of a view parts that can be disassembled easily. The Ambu Oval Silicone Resuscitator can easy be cleaned and autoclaved (except the oxygen reservoir) at a temperature of 134° Celsius.
  • The unique shape is small and easy to hold. The ergonomic, lightweight design of Ambu Oval Silicone Resuscitator is made for optimal user handling and support even during extended ventilations.
  • The resuscitators are semi-transparent allowing for a visual check of the patient’s condition. A pressure limitation valve is optional for the adult version and has been included into the design of the pediatric versions to ensure the safety of the patient*.

* International guidelines recommend that all manual resuscitators for infant and pediatric patients should be equipped with a pressure limitation mechanism so the airway pressure does not exceed 45 cm H2O.

  • Max Load: 250KG(550lb) in movement
  • Material: steel electrostatic spraying
  • Function:Backrest tilting From 0°to 75° ±5°
  • Hi-lo function
  • Reverse:14°±1°
  • Trendelenburg:12°±1°
  • Handset
  • Abdomen auto-extension decompression
  • PU knee crutches
  • Adjustable hand grip
  • phenolic compact laminate (HPL) bed board
  • #304 stainless steel dirty bowl
  • Backrest angle indicator
  • Bumper wheels
  • Pedal remote control
  • Back-up battery
Accessories: 4pcs 5” Taiwan castor with central brake system, 1pair brake pedal, 2pcs PP side rails, 2pcs head and foot board,1 set MOTECK motor, 4pcs bumper wheels, 2pcs angle indicators, 1pc electric cable holder, 2pcs PU knee crutches, 2pcs hand grip, 1pc stainless steel dirty bowl, 1set high density foam mattress, 4pcs Dust cover. Click Here To Download Catalogue
The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional. Full adult and pediatric auscultation is available through its dual head chestpiece simply by rotating the central spline to alternate between the two sides. The more compact one piece diaphragm and rim assemblies have further increased acoustic sensitivity. The binaurals have been redesigned with larger diameter ear tubes and a thicker single lumen binaural to transfer sound more effectively. The selector spline is now recessed to allow a flush fit with the binaural tube and now features a visual indicator for easy identification of the operational diaphragm. Features
  • NEW: double-sided, dual diaphragm chestpiece for both adult and paediatric assessment.
  • NEW: The paediatric side is also easily transformed into a traditional open bell by replacing the single-piece diaphragm with the supplied non-chill rim.
  • NEW: chestpiece is precision-machined into an aesthetically pleasing, less angular shape.
  • NEW: single-piece diaphragm instead of separate diaphragm/rim making it easier to attach and easier to clean due to the smooth unbroken surface.
  • NEW: The stem features an open side indicator to easily identify which diaphragm is in operation.
  • NEW: next-generation tubing gives even longer tube life with improved resistance to skin oils, alcohol and staining.
  • 3M’s ‘Tunable Technology’ lets you easily switch from low to high frequency sounds by switching from light to firm pressure on both the adult and paediatric sides of the chestpiece.
  • High acoustic sensitivity when performing general physical assessment.
  • Laser engraving of text and symbols to personalise your scope and avoid theft/loss
  • Larger ear tubes on the anatomically designed headset comfortably positioned for better sound transfer. Easy adjustment by simply squeezing or pulling apart the eartubes.
  • Comfortable Snap-Tight soft seal eartips create an excellent acoustic seal to reduce ambient noise.
  • No natural rubber latex or phthalate plasticisers are used in the tubing or any other component—to help protect health and the environment.
  • Complement your personal style with Littmann’s large range of chestpiece finishes and tubing colours.
  • Used as a diagnostic aid as part of the physical assessment of a patient.
Littman Stethoscope Features:
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care
  • Fun and vibrant; match colour and finish to your personality
  • Designed for use with adult and pediatric patients
  • tunable, dual-sided stainless steel chest piece with open or closed bell
  • Non-chill bell sleeve for greater patient comfort
  • Soft-sealing ear-tips provide optimal comfort and excellent sound occlusion
  • Made in the USA without natural rubber latex

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare