DynaMesh-IPST

$0.00

Shipped From Abroad

DynaMesh®-IPSTDynaMesh®-IPST visibleDynaMesh®-IPST-D visibleDynaMesh®-IPST-R and DynaMesh®-IPST-R visible implants are intended for the surgical treatment of parastomal hernias, and the prevention (not DynaMesh®-IPST-R or DynaMesh®-IPST-R visible) of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the stoma.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-6
Brands:: Dyna Mesh

Description

ipst-intraperitoneal

 

 

3D Funnel
The device has a passage point with a connected funnel for the passage of the intestine. The base area of the device must be positioned in contact with the tissue, as flat and smooth as possible, with the funnel pointing in the direction of the abdominal cavity.
When selecting the device, the diameter of the passage point should be chosen so that the intestine is tightly sheathed in the funnel.

 

 

 

 

Prefabricated Slit & Smooth Warp-Knitted Selvedges
Only DynaMesh®-IPST-R and DynaMesh®-IPST-R visible have a one-sided slit along the funnel and the base area (mesh flaps), starting from the passage point.
During positioning, the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture.

 

Specifications
Product DynaMesh®-IPST (1)
DynaMesh®-IPST visible (2)
DynaMesh®-IPST-D visible (3)
DynaMesh®-IPST-R (4)
DynaMesh®-IPST-R visible (5)
Surgical Treatment Parastomal Hernia
(Repair / Prevention) (1) – (3) / (Repair) (4) (5)
Surgical Approach Minimally Invasive / Open
Surgical Technique Chimney Technique
Mesh Position Intraperitoneal
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends
gruene_punkte
Smooth Warp-Knitted Selvedges graue_punkte (1) – (3) / gruene_punkte (4) (5)
Visible Technology
graue_punkte (1) (4) / gruene_punkte (2) (3) (5)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) – (5)
– Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) – (5)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (5)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) (3) (5)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR71]
Klinge’s Mesh Classification Class 1a [102P, TR71B]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh®-IPST implants (1)-(5) must be inserted via an appropriate minimally invasive or open approach and must be placed intraperitoneally.

DynaMesh®-IPST implants (1)-(5) have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

When using DynaMesh®-IPST-D visible (3), attention must be paid to the side specificity (left-sided/right-sided stoma), through which a particularly large overlap in a cranial as well as in a medial direction is ensured.

When positioning DynaMesh®-IPST-R and DynaMesh®-IPST-R visible (4) (5), the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture

Click here to download Catalogue.

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-IPST”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDynaMesh-IPST removeDe Lineb Oxygen Face Mask removeIBIS Neeo R9 Digital Surgical C-Arm removeIntersurgical Solus i-gel LMA (Size; 2, 3, 4 & 5) removeSpinal Epidural Pack removePortable Stainless Steel Autoclave Sterilizer remove
NameDynaMesh-IPST removeDe Lineb Oxygen Face Mask removeIBIS Neeo R9 Digital Surgical C-Arm removeIntersurgical Solus i-gel LMA (Size; 2, 3, 4 & 5) removeSpinal Epidural Pack removePortable Stainless Steel Autoclave Sterilizer remove
ImageIBIS Neeo R9 Digital Surgical C-Arm
SKUSF1033560130161-6SF1033560084-39SF1033560011-1SF1033560084-20SF1033560084-25SF1033560084-4
Rating
Price

$0.00

$1.40

$0.00

$12.75

$0.00

$216.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad DynaMesh®-IPSTDynaMesh®-IPST visibleDynaMesh®-IPST-D visibleDynaMesh®-IPST-R and DynaMesh®-IPST-R visible implants are intended for the surgical treatment of parastomal hernias, and the prevention (not DynaMesh®-IPST-R or DynaMesh®-IPST-R visible) of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the stoma.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Our Neeo “C” arms are easy to place, use and are specifically designed to be used in orthopedics, traumatology, abdominal surgery, urology, cardiology and operating rooms. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Made of medical grade Silicone, have good biocompatibility, non-toxic.
  • Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing.
  • Strengthen neck and tip eases insertion and prevents folds.
  • Kink-free tube eliminates the risk of airway tube occlusion.
  • Have different size, suitable for neonate, infant, child and adult.
  • Different color cuff, different material cuff, with aperture bar or not.
  • Reusable types must be cleaned and disinfected or sterilizated before use only 40 times.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

ipst-intraperitoneal

    3D Funnel The device has a passage point with a connected funnel for the passage of the intestine. The base area of the device must be positioned in contact with the tissue, as flat and smooth as possible, with the funnel pointing in the direction of the abdominal cavity. When selecting the device, the diameter of the passage point should be chosen so that the intestine is tightly sheathed in the funnel.    

   

Prefabricated Slit & Smooth Warp-Knitted Selvedges Only DynaMesh®-IPST-R and DynaMesh®-IPST-R visible have a one-sided slit along the funnel and the base area (mesh flaps), starting from the passage point. During positioning, the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture.

 
Specifications
Product DynaMesh®-IPST (1) DynaMesh®-IPST visible (2) DynaMesh®-IPST-D visible (3) DynaMesh®-IPST-R (4) DynaMesh®-IPST-R visible (5)
Surgical Treatment Parastomal Hernia (Repair / Prevention) (1) – (3) / (Repair) (4) (5)
Surgical Approach Minimally Invasive / Open
Surgical Technique Chimney Technique
Mesh Position Intraperitoneal
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends
gruene_punkte
Smooth Warp-Knitted Selvedges graue_punkte (1) – (3) / gruene_punkte (4) (5)
Visible Technology
graue_punkte (1) (4) / gruene_punkte (2) (3) (5)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) – (5) – Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) – (5) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (5) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) (3) (5)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR71]
Klinge’s Mesh Classification Class 1a [102P, TR71B]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests
DynaMesh®-IPST implants (1)-(5) must be inserted via an appropriate minimally invasive or open approach and must be placed intraperitoneally. DynaMesh®-IPST implants (1)-(5) have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface. When using DynaMesh®-IPST-D visible (3), attention must be paid to the side specificity (left-sided/right-sided stoma), through which a particularly large overlap in a cranial as well as in a medial direction is ensured. When positioning DynaMesh®-IPST-R and DynaMesh®-IPST-R visible (4) (5), the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture

Click here to download Catalogue.

De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
Features:
  • Non-toxic PVC
  • Medium concentration
  • Adjustable nose clip
  • Non-Autoclavable
  • Available size: adult, child
  Technical Specifications:
  • Product Name: Oxygen Mask
  • Material: Medical grade PVC
  • Color: Green
  • Size: S, M, L, L , XL
  • Package: PE bag
  • Tube size: 2m
  • Nose Clip: adjustable
  • Disposable Medical Oxygen Face Mask Types MSLMK01
 
Our Neeo “C” arms are easy to place, use and are specifically designed to be used in orthopedics, traumatology, abdominal surgery, urology, cardiology and operating rooms. Using Neeo with the RTP (Real Time Processing) option it is possible to perform vascular, urological and cardiological diagnostics. One of the main functions, digital image subtraction, allows to see, as an example, the passage of contrast liquids in a tissue or in a venous or arterial duct; thanks to the possibility of looping, the acquired video can be reproduced several times to monitor more accurately the passage of the fluid within the area in question. Angiographic measurement is another useful function in the vascular field (QA Quantitative Angiography) that allows the measurement of stenoses. Finally, fluoroscopy allows the correct positioning of stents or expanders. Neeo is used in various interventional and diagnostic procedures in traumatology and orthopedics wards and operating rooms as well. Thanks to low-dose fluoroscopy, it is possible to use the device for positioning bone or subcutaneous grafts, inserting K-wire (Kirschner wire) for stabilization of bone fragments or for the correct positioning of prostheses. The low dose emitted ensures safe use for both the patient and the surgeon or doctor on the operating field. On the control panel there is a large touch screen display that allows to adjust the basic functions of the equipment. From this display it is possible to select and adjust the fluoroscopic data for the examination, activate or deactivate the laser pointer, select between pulsed, one shot or standard fluoroscopy, rotate the image and perform all operations on collimator. The four side buttons on the display offer the possibility to move the bow vertically thanks to an extremely silent motor. Neeo has two 19 “medical grade monitors that can be positioned according to the needs of the medical practitioner. Work monitors and feedback monitors are separated to be managed independently. The possible movements are: rotation, revolution, tilting and possibility of height adjustment. Features:
  • Continuous fluoroscopy
  • Pulsed fluorography
  • One Shot fluoroscopy
  • Low dose fluoroscopy
  • Radiography with cassette (up to 5KW)
  • 110,000 images of memory (Standard)
  • 19 ″ Medical Flat Monitor (X2)
  • Touch control panel
  • Image Processing – 1K X 1K, 16 bit
  • DAP-Dose Area Meter
  • DSA Road Mapping
  • Laser Marker
Technical Specification:
  • Power: 5KW
  • kV Range (kV): 40 - 120
  • mAs Range (mAs): 1 - 250
  • SID (mm): 1000
  • Free Space (mm): 730
DICOM Feature:
  • RTP-SW DSA
  • RTP-SW QA
  • RTP-SW Worklist
  • RTP-SW Print
  • RTP-SW CD DVD Saving
  • RTP-SW MPPS
  • RTP-SW Query/Retrieve
  • RTP-SW HCF
  • RTP-SW BASE
  • RTP-SW STCOMMIT
Configuration: C-Arm Structure, Trolley for Monitor, Collimator, Monoblock, Toshiba 12” Image Intensifier, 19″ Philips Medical Flat Monitor (X2), Camera CD1030CA 1KX1K, Sony Printer UP-X898MD, Cassette Holder
Click Here To Download Catalogue
 
Features:
  • Made of medical grade Silicone, have good biocompatibility, non-toxic.
  • Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing.
  • Strengthen neck and tip eases insertion and prevents folds.
  • Kink-free tube eliminates the risk of airway tube occlusion.
  • Have different size, suitable for neonate, infant, child and adult.
  • Different color cuff, different material cuff, with aperture bar or not.
  • Reusable types must be cleaned and disinfected or sterilizated before use only 40 times.
 
 
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
Features:
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: YX280A
Sterilizing volume 18L
Working pressure 0.14-0.16Mpa
Working temperature 126ºC
Max. safety pressure 0.165Mpa
Characteristics Electric heated
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare