ECROSKHIM Multiple Laboratory Shaker PE-6410 with Heating

$0.00

Shipped From Abroad

Purpose: the device shall be used for the simultaneous stirring of liquids horizontally placed in several vessels volume 100 to 1000 ml. with the possibility of heating.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601225
Brands:: ECROSKHIM

Description

ECROSKHIM Multiple Laboratory Shaker PE-6410 with Heating

Description:

Purpose: the device shall be used for the simultaneous stirring of liquids horizontally placed in several vessels volume 100 to 1000 ml. with the possibility of heating.

Technical specifications:
– Movement – orbital
– Frequency, rpm – 250
– Maximum platform motion, mm – 22
– Max. adjustable temperature of platform heating, °С – +80
– Platform dimension, mm – 435Ñ…315

Platform capacity:
– shaking flask volume 1000 ml – 6 pcs
– shaking flask volume 500 ml – 6 pcs
– shaking flask volume 100 ml – 12 pcs
– separating funnels volume 1000 ml – 2 pcs

– Maximum power consumption, W, not more than – 200
– Mains supply (50 Hz), V – 220 ± 10
– Dimensions, mm – 470Ñ…350Ñ…200

Reviews

There are no reviews yet.

Be the first to review “ECROSKHIM Multiple Laboratory Shaker PE-6410 with Heating”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsECROSKHIM Multiple Laboratory Shaker PE-6410 with Heating removeHawksley 1400 Haematocrit Centrifuge removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun 48 INR Microcuvette removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
NameECROSKHIM Multiple Laboratory Shaker PE-6410 with Heating removeHawksley 1400 Haematocrit Centrifuge removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun 48 INR Microcuvette removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
ImageMultiple laboratory shakerAvalun 48 INR Microcuvette
SKUSF10335601225SF1033560084-118SF1033560060-1SF1033560060-2SF1033560084-74SF1033560084-30
Rating
Price

$0.00

$690.00

$0.00

$0.00

$0.00

$9.50

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
Purpose: the device shall be used for the simultaneous stirring of liquids horizontally placed in several vessels volume 100 to 1000 ml. with the possibility of heating. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
ECROSKHIM Multiple Laboratory Shaker PE-6410 with Heating Description:
Purpose: the device shall be used for the simultaneous stirring of liquids horizontally placed in several vessels volume 100 to 1000 ml. with the possibility of heating. Technical specifications: - Movement – orbital - Frequency, rpm - 250 - Maximum platform motion, mm - 22 - Max. adjustable temperature of platform heating, °С - +80 - Platform dimension, mm - 435х315 Platform capacity: - shaking flask volume 1000 ml - 6 pcs - shaking flask volume 500 ml - 6 pcs - shaking flask volume 100 ml - 12 pcs - separating funnels volume 1000 ml - 2 pcs - Maximum power consumption, W, not more than - 200 - Mains supply (50 Hz), V - 220 ± 10 - Dimensions, mm - 470х350х200
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32ËšC / 5 to 90 %
 
Click Here To Download Catalogue
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8ËšC
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ËšC
Click Here To Download Catalogue
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
Twenty Five (25) Test Strip per Pack
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare