ECROSKHIM PE-5300VI Spectrophotometer

$0.00

Shipped From Abroad

PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601227
Brands:: ECROSKHIM

Description

Description

PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.

Technical specifications:
– Spectral range, nm – 325-1000
– Separable spectral range, nm – 4
– Range of measurement:
a) range of measurement of absorbancy, B – 3.000 to 0.000
b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0
– Optical source – W-lamp
– USB-B cable for connection to a PC
– Overall dimensions, (LxWxH), not more than, mm – 440Ñ…320Ñ…175.
– Weight, not more than, kg – 8.5
– Power consumption, W – 25
– Supply voltage, V – 85-250

The standard equipment of the spectrophotometer includes:
1. PE-5300VI spectrophotometer with holder for 3 cells (RUS standard, width – 24mm, path length – to 100mm)
2. CD with software
complete set of reference light filters (4 filters)
3. Glass cuvettes, RUS standard 10x24mm (4 pcs.)
4. Dust cover
5. USB-A – USB-B cable for connection to a PC
6. Spare halogen bulb
7. Operating manual and Data sheet

PE-5300VI spectrophotometer surpasses its counterparts such as UNICO 1200 (1201), LEKI SS1104, PE-5300V, KFK-3 in a number of metrological and operational characteristics.

Features:
Warranty period – 3 years
Manual setting of wave length
Manual compensation of dark current
Computer software with the possibility of automatic update via the Internet

Reviews

There are no reviews yet.

Be the first to review “ECROSKHIM PE-5300VI Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

ECROSKHIM PE-5300VI Spectrophotometer removeNikon SMZ745 Stereoscopic Microscope removeAvalun LabPad Device removeMotic BA210 Series Biomedical Microscope removeAutomatic Pipette remove8 Bucket Centrifuge remove
NameECROSKHIM PE-5300VI Spectrophotometer removeNikon SMZ745 Stereoscopic Microscope removeAvalun LabPad Device removeMotic BA210 Series Biomedical Microscope removeAutomatic Pipette remove8 Bucket Centrifuge remove
ImageSpectrophotometer PE-5300VINikon SMZ745 Stereoscopic MicroscopeAvalun Labpad machine
SKUSF10335601227SF1033560084-49SF1033560084-65SF1033560084-78SF1033560084-130SF1033560084-114
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$72.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins. Technical specifications: - Spectral range, nm - 325-1000 - Separable spectral range, nm - 4 - Range of measurement: a) range of measurement of absorbancy, B – 3.000 to 0.000 b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0 - Optical source – W-lamp - USB-B cable for connection to a PC - Overall dimensions, (LxWxH), not more than, mm - 440х320х175. - Weight, not more than, kg – 8.5 - Power consumption, W - 25 - Supply voltage, V - 85-250 The standard equipment of the spectrophotometer includes: 1. PE-5300VI spectrophotometer with holder for 3 cells (RUS standard, width – 24mm, path length – to 100mm) 2. CD with software complete set of reference light filters (4 filters) 3. Glass cuvettes, RUS standard 10x24mm (4 pcs.) 4. Dust cover 5. USB-A – USB-B cable for connection to a PC 6. Spare halogen bulb 7. Operating manual and Data sheet PE-5300VI spectrophotometer surpasses its counterparts such as UNICO 1200 (1201), LEKI SS1104, PE-5300V, KFK-3 in a number of metrological and operational characteristics. Features: Warranty period – 3 years Manual setting of wave length Manual compensation of dark current Computer software with the possibility of automatic update via the Internet
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare