ECROSKHIM PE-5400UV Spectrophotometer with Cell Holder for 6 Cuvettes

$0.00

Shipped From Abroad

PE-5400UV spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601229
Brands:: ECROSKHIM

Description

Description

PE-5400UV spectrophotometer with holder for 6 cells (EU standard, width – 10mm, path length – 5-50mm).

PE-5400UV spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.

Technical specifications:
– Spectral range, nm – 190-1000
– Separable spectral range, nm – 4
– Range of measurement:
a) range of measurement of absorbancy, B – 3.000 to 0.000;
b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0
– Optical source – D2-lamp and W-lamp
– USB-B cable for connection to a PC
– Overall dimensions, (LxWxH), not more than, mm – 465Ñ…395Ñ…235
– Weight, not more than, kg – 12.5
– Power consumption, W – 45
– Supply voltage, V – 85-250

The standard equipment of the spectrophotometer includes:
1. PE-5400UV spectrophotometer with holder for 6 cells (EU standard, width – 10mm, path length – up to 50mm)
2. Glass cell 10x10mm – 4 pcs
3. Quartz cell 10x10mm – 2 pcs
4. *complete set of reference light filters (4filters)
5. *spare halogen bulb (12 V, 20 W)
6. *power cord
7. USB-A – USB-B cable for connection to a PC
8. Dust cover
9. Operating manuals and Data sheet

PE-5400UV spectrophotometer surpasses its counterparts such as UNICO 2100UV, LEKI SS1207UV, SPEKOL 1300 in a number of technical and metrological specifications.

Features:
Warranty period – 3 years
Manual setting of wave length
Manual compensation of dark current

– Possibility of wavelength scanning with the use of scanning program SC5400 for a PC (the software can be supplied separately)
– The instrument is able to store up to 200 items and 200 calibration graphs (without connection to a PC)
– Quick setup of wavelength by means of display keyboard or PC.
– Large cell holder allows setting up the following holders:
a) Holder for 4 cells (RUS) with path length 5-100 mm (standard accessory)
b) Holder for 6 narrow cells (width – 12mm, path length – 5-50 mm)
– Computer software with the possibility of automatic update via the Internet

Reviews

There are no reviews yet.

Be the first to review “ECROSKHIM PE-5400UV Spectrophotometer with Cell Holder for 6 Cuvettes”

Your email address will not be published. Required fields are marked *

Quick Comparison

ECROSKHIM PE-5400UV Spectrophotometer with Cell Holder for 6 Cuvettes removeDiscover 14 Panel Cup with Adulterants Per Pack removeEppendorf Pipette Tip 20ul Per Pack remove8 Bucket Centrifuge removeAvalun LabPad Device removeSugentech Inclix (POCT) Immunoassay Analyzer remove
NameECROSKHIM PE-5400UV Spectrophotometer with Cell Holder for 6 Cuvettes removeDiscover 14 Panel Cup with Adulterants Per Pack removeEppendorf Pipette Tip 20ul Per Pack remove8 Bucket Centrifuge removeAvalun LabPad Device removeSugentech Inclix (POCT) Immunoassay Analyzer remove
ImageSpectrophotometer PE-5400UV (with holder for 6 cells)Drug Test CupEppendorf Pipette Tip 20ul Per PackAvalun Labpad machine
SKUSF10335601229SF1033560084-28SF1033560084-136SF1033560084-114SF1033560084-65SF1033560084-89
Rating
Price

$0.00

$0.00

$0.00

$72.50

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
PE-5400UV spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
PE-5400UV spectrophotometer with holder for 6 cells (EU standard, width – 10mm, path length – 5-50mm). PE-5400UV spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins. Technical specifications: - Spectral range, nm - 190-1000 - Separable spectral range, nm - 4 - Range of measurement: a) range of measurement of absorbancy, B – 3.000 to 0.000; b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0 - Optical source – D2-lamp and W-lamp - USB-B cable for connection to a PC - Overall dimensions, (LxWxH), not more than, mm - 465х395х235 - Weight, not more than, kg – 12.5 - Power consumption, W - 45 - Supply voltage, V - 85-250 The standard equipment of the spectrophotometer includes: 1. PE-5400UV spectrophotometer with holder for 6 cells (EU standard, width – 10mm, path length – up to 50mm) 2. Glass cell 10x10mm – 4 pcs 3. Quartz cell 10x10mm – 2 pcs 4. *complete set of reference light filters (4filters) 5. *spare halogen bulb (12 V, 20 W) 6. *power cord 7. USB-A – USB-B cable for connection to a PC 8. Dust cover 9. Operating manuals and Data sheet PE-5400UV spectrophotometer surpasses its counterparts such as UNICO 2100UV, LEKI SS1207UV, SPEKOL 1300 in a number of technical and metrological specifications. Features: Warranty period – 3 years Manual setting of wave length Manual compensation of dark current - Possibility of wavelength scanning with the use of scanning program SC5400 for a PC (the software can be supplied separately) - The instrument is able to store up to 200 items and 200 calibration graphs (without connection to a PC) - Quick setup of wavelength by means of display keyboard or PC. - Large cell holder allows setting up the following holders: a) Holder for 4 cells (RUS) with path length 5-100 mm (standard accessory) b) Holder for 6 narrow cells (width – 12mm, path length – 5-50 mm) - Computer software with the possibility of automatic update via the Internet
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
INCLIXâ„¢ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIXâ„¢ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare