Entroplum Forceps Serrated Handle With Locking Thumb Screw, Left Plate, 90mm

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013094-35
Brands:: HASA-OPTIX

Reviews

There are no reviews yet.

Be the first to review “Entroplum Forceps Serrated Handle With Locking Thumb Screw, Left Plate, 90mm”

Your email address will not be published. Required fields are marked *

1 2 3 4 5

Quick Comparison

SettingsEntroplum Forceps Serrated Handle With Locking Thumb Screw, Left Plate, 90mm removePortable Keratometer removeOperation Microscope removeAutomatic Computer Goldmann (Visual Field Analyzer) removePortable Rebound Tonometer removeApplanation Tonometer remove
NameEntroplum Forceps Serrated Handle With Locking Thumb Screw, Left Plate, 90mm removePortable Keratometer removeOperation Microscope removeAutomatic Computer Goldmann (Visual Field Analyzer) removePortable Rebound Tonometer removeApplanation Tonometer remove
ImageMecan SW 100 Portable KeratometerMecan YZ20P5 Operation MicroscopeMecan SW-500 Portable Rebound TonometerMecan Applanation Tonometer YZ30X
SKUSF103356013094-35SF1033560107-16SF1033560107-24SF103356013013SF1033560107-17SF1033560107-1
Price

$0.00

$0.00

$2,695.00

$3,850.00

$1,815.00

$0.00

Add to cart
DescriptionShipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad YZ20P5 Operation Microscope is a simple binocular coaxial microscope for a single man. The Operation  Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Content Portable Keratometer Features: Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data. Technical Specifications:
Model SW-100
Measuring Range 6.5mm~9.5mm: ±0.05mm: 0.01mm
Precision ± 0.05mm
Resolution of Curvature Radius of Cornea 0.01mm
Single Measuring Time 0.03s
Output Wireless Infrared Thermal Printer
Can observe the eye directly through the screen.
Weight 0.5Kg(with batteries)
Dimension 240mmx90mmx60mm
Power 500mW+15%
Operation Microscope(YZ20P5) is a simple binocular coaxial microscope for a single man. The Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment. Features of Operation Microscope:
  • Multi-layer coating technology is used on optical lenses to enhance the transmission rate and prevent mildew.
  • Foot-controlled focus, three-step magnification change, good depth of field of view, and good binocular fusion to meet the need of cataract surgery.
  • Using apochromatic technology to make different wavelengths of the light focus near the focal point behind the lens, so as to make the operator's vision more clearly.
  • The machine weighs only 41Kg to be light and compact and is especially applicable for mobile medical.
  • Optional desktop components to make the machine more portable and can also be customized according to special requirements to meet the needs in ophthalmology, ENT and other surgery.
  • Optional F250/F300/F400 lens.
Technical Specifications of Operation Microscope:

Eyepiece Magnification

12.5×

Focal Length of Objective Lens

F=200

Working Distance

190 mm

Magnification for Main Microscope

5.3×, 8×, 16×

Diameter of Field

37 mm, 25 mm, 16.7 mm

Diopter Adjustment

±5D

Pupillary Distance

50 mm ~ 70 mm

Maximum Resolution

100 LP/mm

Light Source

12V/100W halogen lamp for medical use

Illumination Type

 6° coaxial illumination of the cold light source

Coaxial Illuminance

≥30,000 Lx

Reaching Radius of Arm

870 mm

Adjustable Vertical Range

700 mm~1100 mm

Fine Focusing Range 30 mm

Input Voltage

AC 220V/110V±10%, 50Hz/60Hz

Power Consumption

120 VA

Fuse

AC 250V   T4.0A, AC 125V  T8.0A

Electrical Safety Standard

IEC 60601-1, Class I

Packing Volume 

0.2 m3,1 carton

Total Weight 

41 kg

 
Click Here To Download Catalogue 
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare