/ / / /

Fluoride Oxalate Tubes Per Pack

$0.00

In stock

ESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-161

Description

ESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations. Glucose values in unpreserved blood samples deteriorate swiftly after collection as glucose is used by the blood cells. The Fluoride will stop enzymatic activity while oxalate acts as an anticoagulant. Mixing recommendation: Fluoride/Oxalate tubes should be gently inverted 180º and back 8-10 times. Centrifugation instructions: 1300g for 10 minutes at 25º C room temperature.

Item Code Cap Colour Rubber Stopper Size(mm) Volume(ml) Additives Material
VCT2091 GREY Short,Grey 13*75 2.0 Fluoride Oxalate PET TUBES
VCT3091 GREY Short,Grey 13*75 3.0 Fluoride Oxalate PET TUBES
VCT4091 GREY Short,Grey 13*75 4.0 Fluoride Oxalate PET TUBES

Reviews

There are no reviews yet.

Be the first to review “Fluoride Oxalate Tubes Per Pack”

Your email address will not be published. Required fields are marked *

Quick Comparison

Fluoride Oxalate Tubes Per Pack removeAlcohol Pad Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removePlastic Urine Container Per Pack removeSugentech Inclix (POCT) Immunoassay Analyzer remove
NameFluoride Oxalate Tubes Per Pack removeAlcohol Pad Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removePlastic Urine Container Per Pack removeSugentech Inclix (POCT) Immunoassay Analyzer remove
Image
SKUSF1033560084-161SF1033560084-64SF1033560060-1SF1033560084-30SF1033560084-106SF1033560084-89
Rating
Price

$0.00

$4.25

$0.00

$9.50

$8.20

$0.00

Stock
Availability
Add to cart

DescriptionIn stock ESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations. Glucose values in unpreserved blood samples deteriorate swiftly after collection as glucose is used by the blood cells. The Fluoride will stop enzymatic activity while oxalate acts as an anticoagulant. Mixing recommendation: Fluoride/Oxalate tubes should be gently inverted 180º and back 8-10 times. Centrifugation instructions: 1300g for 10 minutes at 25º C room temperature.
Item Code Cap Colour Rubber Stopper Size(mm) Volume(ml) Additives Material
VCT2091 GREY Short,Grey 13*75 2.0 Fluoride Oxalate PET TUBES
VCT3091 GREY Short,Grey 13*75 3.0 Fluoride Oxalate PET TUBES
VCT4091 GREY Short,Grey 13*75 4.0 Fluoride Oxalate PET TUBES
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
Twenty Five (25) Test Strip per Pack
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare