Fluoride Oxalate Tubes Per Pack

$0.00

In stock

ESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-161

Description

ESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations. Glucose values in unpreserved blood samples deteriorate swiftly after collection as glucose is used by the blood cells. The Fluoride will stop enzymatic activity while oxalate acts as an anticoagulant. Mixing recommendation: Fluoride/Oxalate tubes should be gently inverted 180º and back 8-10 times. Centrifugation instructions: 1300g for 10 minutes at 25º C room temperature.

Item Code Cap Colour Rubber Stopper Size(mm) Volume(ml) Additives Material
VCT2091 GREY Short,Grey 13*75 2.0 Fluoride Oxalate PET TUBES
VCT3091 GREY Short,Grey 13*75 3.0 Fluoride Oxalate PET TUBES
VCT4091 GREY Short,Grey 13*75 4.0 Fluoride Oxalate PET TUBES

Reviews

There are no reviews yet.

Be the first to review “Fluoride Oxalate Tubes Per Pack”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsFluoride Oxalate Tubes Per Pack removeDiscover 14 Panel Cup with Adulterants Per Pack removeHawksley 1400 Haematocrit Centrifuge removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeErma B-111 Bilirubin Meter removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
NameFluoride Oxalate Tubes Per Pack removeDiscover 14 Panel Cup with Adulterants Per Pack removeHawksley 1400 Haematocrit Centrifuge removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeErma B-111 Bilirubin Meter removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
ImageDrug Test Cup
SKUSF1033560084-161SF1033560084-28SF1033560084-118SF1033560060-1SF1033560084-6SF1033560084-30
Rating
Price

$0.00

$0.00

$690.00

$0.00

$715.00

$9.50

Stock
Availability
Add to cart

DescriptionIn stock ESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentESR is a simple, non-specific screening test utilized for monitoring the presence of this PET Fluoride/Oxalate Glucose Blood Collection tube is utilized for glucose determinations. Glucose values in unpreserved blood samples deteriorate swiftly after collection as glucose is used by the blood cells. The Fluoride will stop enzymatic activity while oxalate acts as an anticoagulant. Mixing recommendation: Fluoride/Oxalate tubes should be gently inverted 180º and back 8-10 times. Centrifugation instructions: 1300g for 10 minutes at 25º C room temperature.
Item Code Cap Colour Rubber Stopper Size(mm) Volume(ml) Additives Material
VCT2091 GREY Short,Grey 13*75 2.0 Fluoride Oxalate PET TUBES
VCT3091 GREY Short,Grey 13*75 3.0 Fluoride Oxalate PET TUBES
VCT4091 GREY Short,Grey 13*75 4.0 Fluoride Oxalate PET TUBES
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Twenty Five (25) Test Strip per Pack
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare