Hersill Genesis Anaesthetic Machine

Ask for Price$0.00

Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)

Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560450-1
Brands:: Hersill

Description

The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.

 

TECHNICAL SPECIFICATION

OPERATING DATA

  • Weight – 105 kg
  • Dimensions – 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions – 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply – 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input – 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy – 90 min typically
  • Auxiliary power outlets – 4, with automatic protection
  • O2, N2O and Air supply – 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen – TFT 18.5″ (47 cm) projected capacitive touchscreen
  • Protection class – Class I, gas analyser type BF defibrillation proof
  • Classification – Class II b
  • Storage – One front drawer with self-brake system and two back cabinets with door
  • Lighting – LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems – Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports – 1 x RS-232, 2 x USB, 1 x LAN Ethernet

Fresh Gases (02, N20 and Air, electronically controlled)

  • Fresh gas flow – 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy – 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration – 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) – 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) – 40 L/min standard (adjustable 25 – 75 L/min upon requirement)

Breathing System (CABS)

  • Autoclavable – 134 °C
  • Weight of breathing system – 9.8 kg
  • C02 absorber volume – 1.5 L
  • Leakage – < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL – 0 to 70 hPa
  • Pressure relief valve – 125 hPa
  • Vacuum safety valve – 0.3 hPa
  • resistance at 60L/min – 5.80 hPa
  • resistance at 60L/min – 2.90 hPa
  • resistance at 30L/min – 3.55 hPa
  • resistance at 30L/min – 0.89 hPa
  • Internal Compliance at 30 hPa – 15 mL

 

VENTILATOR

Operation / Ventilation Modes

Volume controlled (VC) modes:

  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *

Pressure controlled (PC) modes:

  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *

Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)

  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *

Pressure Support Ventilation (PSV) *

  • (other trade names: PS, ASB, SPS, IPS)

 

Non-mechanical Operation / Ventilation Modes

  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, …)

Application field: Neonates, Pediatrics & Adults

  • Tidal volume – 5 to 1500 mL
  • Inspiratory pressure – 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time – 0.05 to 16.6s
  • l:E ratio – 5:1 to 1:8
  • Inspiratory pause – 0 to 60%
  • Inspiratory flow – max. 150 L/min
  • PEEP – 0 to 30 hPa
  • Flow trigger – 0.2 to 15 L/min
  • Pressure support – 5 to 50 hPa
  • Ramp time – 0.1 to 2 s
  • Maximum pressure – 0 to 68 hPa

 

MONITORING

  • 5″ (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic

 

Click Here To Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Hersill Genesis Anaesthetic Machine”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHersill Genesis Anaesthetic Machine removeNihon Kohden Neuropack S3 Electromyogram (EMG) Machine removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeFirst Aid Box Aluminium Small removeFeeding Table removeSyringe Needle Destroyer remove
NameHersill Genesis Anaesthetic Machine removeNihon Kohden Neuropack S3 Electromyogram (EMG) Machine removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeFirst Aid Box Aluminium Small removeFeeding Table removeSyringe Needle Destroyer remove
ImageHersill Genesis Anaesthetic MachineElectromyogram (EMG) MachineOPTIKA B-382PL-ALC Binocular Brightfeld Microscope
SKUSF1033560450-1SF1033560020-3SF1033560098-13SF1033560084-252SF1033560084-195SF1033560084-206
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

$49.50

$31.50

$157.00

Stock
Availability
Add to cart

DescriptionShipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from abroad The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Strong wooden top.
  • With Casters for easy movement.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Features:
  • State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms
  • Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals
  • Electrode input impedance of 200 MΩ ±20% helps ensure clean signals
  • On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations
  • HL7® gateway integration helps ensure quick flow of information and streamlines workflow
  • Intuitive control panel and stimulators aid in acquiring and progressing through studies
  • Customizable protocols shorten examination time
  • One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values
  • Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations
  • Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage
  Technical Specifications: Main unit: DC-960B Electrode junction box, 2 or 4 ch: JB-962B or JB-964B Control unit, desktop: GG-961BK Power supply: SC-230BK Cart: KD-026A Arm: KH-960A Holder: DI-961B Somato control box: RY-960B LCD display: Local purchase Printer: Local purchase Number of channels: 2 or 4 Input impedance Common mode: >100 MΩ Differential Mode: >200 MΩ CMRR Differential Mode: >106 dB Isolation Mode: >112 dB Noise level: 0.6 μVrms Sampling Resolution: 18 bit Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div. Low-cut filter: 0.01 Hz to 3 kHz High-cut filter: 10 kHz to 20 kHz Analysis time base: 0.1 ms/div to 1 s /div Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation  
Click Here To Download Catalogue
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             
Observation mode: Brightfield. Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged). Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 N-PLAN 100x/1.25 (Oil/Water) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
First Aid Box Aluminium Small contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
  • Strong wooden top.
  • With Casters for easy movement.
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar