Horizontal Pressure Steam Autoclave

$0.00

Shipped From Abroad

Horizontal Pressure Steam Autoclave uses saturated steam as the sterilization medium,exhausts the cold air by gravity. So that the saturated steam fully penetrates the surface of the items. By utilizing high-temperature saturated steam under high pressure, it effectively kills all microorganisms and their spores, providing reliable sterilization results. It is considered one of the most effective methods among physical sterilization techniques. It is widely used in fields such as pharmaceuticals, biotechnology, and laboratories for sterilizing items such as dressing/fabrics, medical instruments, rubber, and liquids.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-43
Brands:: Scitek

Description

Horizontal Pressure Steam Autoclave Features:
  1. Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
  2. Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected.
  3. Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point).
  4. Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water.
  5. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
  6. Electrical circuit safety device for over-current and shortcut protection.
  7. Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen.
  8. Built-in steam generator prevents the media from contamination.
  9. Buzzer for working errors and the end of the cycle.
  10. Automatic atmospheric pressure adjustment for the installation and operation in plateau areas.
  11. Optional printer, real-time record sterilization process, error and alarm information.

 

Horizontal Pressure Steam Autoclave Specifications:
Model ST-H60 ST-H80 ST-H100 ST-H135 ST-H150 ST-H185 ST-H200 ST-H300 ST-H450
Capacity 60L 80L 100L 135L 150L 185L 200L 300L 450L
External Size

(WxDxH)(mm)

985x600x1450 985x600x1450 1200x600x1450 1000x710x1550 1330x710x1550 1250x710x1550 1320x710x1550 1350x900x1750 1750x900x1750
Chamber Size

(ØxH)(mm)

Ø386×500 Ø386×700 Ø386×950 Ø500×700 Ø500×780 Ø500×950 Ø500×1000 Ø650×950 Ø650×1360
Chamber

Material

SUS304
Sterilization

Temperature

105~136 ℃
Designed

Temperature

150℃
Max.Working

Temperature

136 ℃
Temp.Accuracy 0.1℃
Temp.Uniformity ≤±0.5℃
Designed

Pressure

0.3Mpa
Sterilization

Pressure

0.23Mpa
Temp. Controller PID control by microprocessor
Display LCD touch screen
Drying Function YES
Drying Time 15min
Sterilization

Program

●Dressings/Fabric program  ●Medical instrument program  ●Rubber program  ●Liquid program  ●DIY program
Power

Consumption

5.7KW 5.7KW 6KW 9.35KW 9.35KW 10.8KW 10.8KW 12KW 20KW
Power Supply 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz
Standard

Sterilization

Shelf

1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs
Optional

Accessories

Printer
Net Weight 105kg 120kg 140kg 225kg 240kg 255kg 265kg 350kg 450kg
Gross Weight 165kg 185kg 210kg 315kg 340kg 365kg 380kg 470kg 570kg
Shipping Size

(WxDxH)(mm)

1280x700x1600 1280x700x1600 1450x700x1600 1300x850x1900 1400x900x1900 1440x930x2020 1490x930x2020 1650x1100x2120 2100x1100x2120

Reviews

There are no reviews yet.

Be the first to review “Horizontal Pressure Steam Autoclave”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHorizontal Pressure Steam Autoclave removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeSugentech Inclix (POCT) Immunoassay Analyzer removeHawksley 1400 Haematocrit Centrifuge remove
NameHorizontal Pressure Steam Autoclave removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeSugentech Inclix (POCT) Immunoassay Analyzer removeHawksley 1400 Haematocrit Centrifuge remove
ImageDrug Test Cup
SKUSF1033560130127-43SF1033560084-6SF1033560084-125SF1033560084-28SF1033560084-89SF1033560084-118
Rating
Price

$0.00

$715.00

$1,320.00

$0.00

$0.00

$690.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Horizontal Pressure Steam Autoclave uses saturated steam as the sterilization medium,exhausts the cold air by gravity. So that the saturated steam fully penetrates the surface of the items. By utilizing high-temperature saturated steam under high pressure, it effectively kills all microorganisms and their spores, providing reliable sterilization results. It is considered one of the most effective methods among physical sterilization techniques. It is widely used in fields such as pharmaceuticals, biotechnology, and laboratories for sterilizing items such as dressing/fabrics, medical instruments, rubber, and liquids.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Horizontal Pressure Steam Autoclave Features:
  1. Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
  2. Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected.
  3. Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point).
  4. Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water.
  5. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
  6. Electrical circuit safety device for over-current and shortcut protection.
  7. Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen.
  8. Built-in steam generator prevents the media from contamination.
  9. Buzzer for working errors and the end of the cycle.
  10. Automatic atmospheric pressure adjustment for the installation and operation in plateau areas.
  11. Optional printer, real-time record sterilization process, error and alarm information.
 
Horizontal Pressure Steam Autoclave Specifications:
Model ST-H60 ST-H80 ST-H100 ST-H135 ST-H150 ST-H185 ST-H200 ST-H300 ST-H450
Capacity 60L 80L 100L 135L 150L 185L 200L 300L 450L
External Size (WxDxH)(mm) 985x600x1450 985x600x1450 1200x600x1450 1000x710x1550 1330x710x1550 1250x710x1550 1320x710x1550 1350x900x1750 1750x900x1750
Chamber Size (ØxH)(mm) Ø386x500 Ø386x700 Ø386x950 Ø500x700 Ø500x780 Ø500x950 Ø500x1000 Ø650x950 Ø650x1360
Chamber Material SUS304
Sterilization Temperature 105~136 ℃
Designed Temperature 150℃
Max.Working Temperature 136 ℃
Temp.Accuracy 0.1℃
Temp.Uniformity ≤±0.5℃
Designed Pressure 0.3Mpa
Sterilization Pressure 0.23Mpa
Temp. Controller PID control by microprocessor
Display LCD touch screen
Drying Function YES
Drying Time 15min
Sterilization Program ●Dressings/Fabric program  ●Medical instrument program  ●Rubber program  ●Liquid program  ●DIY program
Power Consumption 5.7KW 5.7KW 6KW 9.35KW 9.35KW 10.8KW 10.8KW 12KW 20KW
Power Supply 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz
Standard Sterilization Shelf 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs
Optional Accessories Printer
Net Weight 105kg 120kg 140kg 225kg 240kg 255kg 265kg 350kg 450kg
Gross Weight 165kg 185kg 210kg 315kg 340kg 365kg 380kg 470kg 570kg
Shipping Size (WxDxH)(mm) 1280x700x1600 1280x700x1600 1450x700x1600 1300x850x1900 1400x900x1900 1440x930x2020 1490x930x2020 1650x1100x2120 2100x1100x2120
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare