Internal Sidestream ETCO2 Sensor LH820
$0.00
Shipped From Abroad
LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Internal Sidestream ETCO2 Sensor LH820
- Suitable for incubated and non-incubated patients.
- Plug and play, long service life
- No calibration required
- Barometer pressure: CO2, N2O, HE compensation for accurate measurement
- Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
- Checking and confirming ET tube placement
- Detecting ventilator airway connection
- Fully compatible with Respironics module’s protocol
- Customized connector
Specifications of Internal Sidestream ETCO2 Sensor LH820
Principle | NDIR |
CO2 Measuring range | 0-150mmHg |
0 – 19.7 % | |
0 – 20 kPa | |
Accuracy | 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading. |
Respiration | 3 – 120 BPM; Accuracy: ±1 BPM |
Voltage & Power | 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W) |
Interface | RS232, TTL (customized) |
Temp & Humidity | Operating: 0º to 40°, 10 to 90% RH, |
Storage: -40º to 70ºC, <90% RH |
Compatible Brands:
![]() |
![]() |
|
![]() |
Philips | Nihon Kohden | Mindray | Biolight |
![]() |
![]() |
![]() |
![]() |
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical | Contec | Comen | Masimo |
Quick Comparison
Settings | Internal Sidestream ETCO2 Sensor LH820 remove | Render SD-M2000A Anesthetic Machine remove | Render SD-M2000B Anesthetic Machine remove | Lab/Ward Coat remove | Littman Stethoscope remove | Bistos BT-770-12.1" Touchscreen Patient Monitor remove | |||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Internal Sidestream ETCO2 Sensor LH820 remove | Render SD-M2000A Anesthetic Machine remove | Render SD-M2000B Anesthetic Machine remove | Lab/Ward Coat remove | Littman Stethoscope remove | Bistos BT-770-12.1" Touchscreen Patient Monitor remove | |||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130174-4 | SF1033560011-13 | SF1033560011-10 | SF1033560084-222 | SF1033560084-5 | SF1033560059-1 | |||||||||||||||||||||||||||||||||||||||||||
Rating | |||||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $1,870.00 | $4,840.00 | $11.00 | $13.20 | $902.00 | |||||||||||||||||||||||||||||||||||||||||||
Stock | |||||||||||||||||||||||||||||||||||||||||||||||||
Availability | |||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | |||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
| Shipped from Abroad
| In stock
| In Stock
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | |||||||||||||||||||||||||||||||||||||||||||
Content | Features of Internal Sidestream ETCO2 Sensor LH820
Specifications of Internal Sidestream ETCO2 Sensor LH820
Compatible Brands:
|
Click Here To Download Catalogue |
Click Here To Download Catalogue |
| Littman Stethoscope Features:
|
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations.
SPECIFICATIONS
Click Here To Download Catalogue | |||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||||||
Additional information |