The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory.

Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601250
Brands:: Kedee

Description

The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning.

Technical Specifications:

  • Section Thickness Setting Range: 0–60μm
  • Section thickness settingoptions:

     0–2μm       increment 0.25μm

     2–10μm       increment 1μm

    10–20μm      increment 2μm

    20–60μm      increment 5μm

  • Trimming Thickness Setting Range: 0- 60μm
  • Minimum Setting of Sectioning Thickness: 1μm
  • Total Horizontal Specimen Feed:29mm;
  • Vertical Specimen Stroke:60mm
  • Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
  • Movement Range of the Blade Press plate: 0-23mm
  • Specimen Holder Rotation: at any angle within360 degrees
  • Maximum Specimen Size: 60×70mm
  • Specimen Orientation:XY – 8°
  • Precision Error: ±1%
  • Dimensions: 570×440×290mm (W×D×H)
  • Net weight: 28kg

Review(1)

5.00 average based on 1 ratings.
  1. Meshack shiundu

    Hello,please email me the operation manual for this brand.Thanks

Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

KEDEE KD-2260 Manual Rotary Microtome removeEppendorf Pipette Tip 200ul Per Pack removeAvalun LabPad Device removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeAvalun 48 INR Microcuvette removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameKEDEE KD-2260 Manual Rotary Microtome removeEppendorf Pipette Tip 200ul Per Pack removeAvalun LabPad Device removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeAvalun 48 INR Microcuvette removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageEppendorf Pipette Tip 200ul Per PackAvalun Labpad machineAvalun 48 INR Microcuvette
SKUSF10335601250SF1033560084-137SF1033560084-65SF1033560084-30SF1033560084-74SF1033560084-125
Rating
Price

$2,970.00

$0.00

$0.00

$9.50

$0.00

$1,320.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShip From Abroad

The Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory.

Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe Microtome KD-2260 is designed to meet multiple requirements of histology or histopathology labs. It is also suitable for the use in research labs as well as industrial quality assurance. In being manual, the Microtome KD-2260 is flexible to use at any place in the laboratory. With its high-precision mechanics inside, the Microtome KD-2260 permits quality sections, while maintaining a high, consistent throughput. Great functionality and the appealing design are the key features of our microtome. Optimal user comfort enables a rapid, safe and smooth sectioning, even under heavy workload. The integrated sectioning waste tray is resistant to xylene, and can be detached for cleaning. Technical Specifications:
  • Section Thickness Setting Range: 0–60μm
  • Section thickness settingoptions:
     0–2μm       increment 0.25μm      2–10μm       increment 1μm     10–20μm      increment 2μm     20–60μm      increment 5μm
  • Trimming Thickness Setting Range: 0- 60μm
  • Minimum Setting of Sectioning Thickness: 1μm
  • Total Horizontal Specimen Feed:29mm;
  • Vertical Specimen Stroke:60mm
  • Movement Range of the Base of BladeHolder Base: 0-60mm (front to back)
  • Movement Range of the Blade Press plate: 0-23mm
  • Specimen Holder Rotation: at any angle within360 degrees
  • Maximum Specimen Size: 60×70mm
  • Specimen Orientation:XY – 8°
  • Precision Error: ±1%
  • Dimensions: 570×440×290mm (W×D×H)
  • Net weight: 28kg
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
Twenty Five (25) Test Strip per Pack
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare