Description | Shipped From Abroad
Features:
◆Quick heating, long lifespan, and energy-saving, due to the use of a new-type heating element;
◆Both actual and preset temperatures are displayed;
◆Automatic memory and restoration functions: After startup, all preset temperature data are automatically stored in the system;
◆Special black surface material characterized by its strong resistance to abrasion and corrosion
Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
OPTIKA B-510 Series represents the ideal, ultra-modern, advanced routine microscope for efficient analysis in transmitted light applications, carefully engineered considering all the relevant aspects for users.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Classification: Laboratory Thermostatic Devices
- Brand Name: Zenith Lab
- Model Number: DHG-9070A
- Working size(mm): 450*350*450
- Power: 1000W
- Temperature range: 50~200℃
- Temperature resolution: 0.1℃
- Temperature fluctuation: ±1℃
- Timer: 0-999min
- Voltage: 110V 60Hz /220V 50Hz
- Dimension(mm): 620*710*620
- Weight: 45kg
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | KEDEE KD-H Slide Dryer (Oven) Features:
◆Quick heating, long lifespan, and energy-saving, due to the use of a new-type heating element;
◆Both actual and preset temperatures are displayed;
◆Automatic memory and restoration functions: After startup, all preset temperature data are automatically stored in the system;
◆Special black surface material characterized by its strong resistance to abrasion and corrosion | Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
- Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
- Max. speed: 14,100 x g (14,500 rpm)
- Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
- Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
- Rotor can be autoclaved at 121°C for 20 minutes
- Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
- Eliminate costly repairs with the low maintenance drive
- Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: |
800 – 13,400 rpm (100 rpm steps) |
Capacity: |
12 x 1.5/2.0 mL |
Electrical: |
120 V, 60 Hz |
Dimensions: |
(W x D x H) 22.6 x 23.9 x 12.0 cm |
Weight: |
4.3 kg |
| Observation mode: Brightfield.
Head: Trinocular (fixed photo port 50/50), 30° inclined, 360° rotating.
Interpupillary distance: Adjustable between 50 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: Main head: WF10x/22 mm, high eye-point and with rubber cups. Additional head(s): WF10x/20 mm, high eye-point.
Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
Objectives (strain-free):
– IOS W-PLAN 4x/0.10
– IOS W-PLAN 10x/0.25
– IOS W-PLAN 40x/0.65
– IOS W-PLAN 100x/1.25 (Oil)
All with anti-fungus treatment.
Specimen stage: Double layer rackless mechanical stage, 233×147 mm, 78×54 mm X-Y range.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
Condenser: Swing-out N.A. 0.2/0.9, with iris diaphragm, focusable and centerable.
Transmitted illumination (Full Koehler type): X-LED3 with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
Specifications:
Optics |
Image scale |
4-100 |
Number of objectives |
4 |
Lighting |
Transmitted light |
Field curvature |
Plan |
Colour correction |
achromatic |
Suspension |
yes |
Immersion lens |
yes |
Condensor |
Abbe N.A.1.25 |
Lamp type |
LED (X-LED3, 3.6 W, comparable to a 50 W halogen bulb) |
Objective 1 |
IOS W-PLAN 4x/0.10, W.D. 17.3 mm |
Objective 2 |
IOS W-PLAN 10x/0.25, W.D. 10 mm |
Objective 3 |
IOS W-PLAN 40x/0.65, W.D. 0.54 mm |
Objective 4 |
IOS W-PLAN 100x/1.25, W.D. 0.13 mm, oil |
Eyepiece |
WF 10x / 22 mm (Ø 30mm) |
infinity corrected |
yes |
Magnification |
40-1000 |
Optical system |
infinity |
Capacity |
Brightness control |
yes |
Fluorescence |
yes |
brightfield |
yes |
Mechanics |
Type of build |
Trinocular |
Viewing posture (°) |
30° angled eyepiece |
Specimen stage |
Cross table |
Revolver |
5 |
Focusing |
Coarse and fine movement |
General |
Weight (g) |
9100 |
Height (mm) |
420 |
Width (mm) |
270 |
Length (mm) |
390 |
Series |
B-510 |
Field of application |
Biology and Medicine |
yes |
|
- Classification: Laboratory Thermostatic Devices
- Brand Name: Zenith Lab
- Model Number: DHG-9070A
- Working size(mm): 450*350*450
- Power: 1000W
- Temperature range: 50~200℃
- Temperature resolution: 0.1℃
- Temperature fluctuation: ±1℃
- Timer: 0-999min
- Voltage: 110V 60Hz /220V 50Hz
- Dimension(mm): 620*710*620
- Weight: 45kg
| The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.
Features:
- Compact, ergonomic design
- Ergonomically designed handwheel handle
- Smooth-running handwheel with integrated quick-lock mechanism for safety
- Enclosed micrometer feed mechanism
- Low-maintenance cross-roller bearings
- Two forward and backward coarse feed speeds
- Alternate trimming and sectioning modes, as indicated on the display
- Speed control through the cutting window for enhanced efficiency
- Automatic, variable specimen retraction, depending on sectioning speed
- Section thickness totalizer and section counter
- Intuitive control panel
- Integrated communication display
- Precise specimen orientation with zero point reference
- Knife holder design with red colored knife guard
- Precise lateral knife holder adjustment with click stop settings
- Spacious and easy-to-clean section waste tray
- Wide range of accessories
Technical Specifications:
Section thickness
Setting thickness setting range: 0.5 – 100 µm
Setting values: from 0.5 – 5 µm in 0.5 µm increments
from 5 – 20 µm in 1 µm increments
from 20 – 60 µm in 5 µm increments
from 60 – 100 µm in 10 µm increments
Trimming section thickness setting range: 1 – 600 µm
Setting values: from 1 – 10 µm in 1 µm increments
from 10 – 20 µm in 2 µm increments
from 20 – 50 µm in 5 µm increments
from 50 – 100 µm in 10 µm increments
from 100 – 600 µm in 50 µm increments
Object feed: 24 mm ± 1 mm, feed motion via step motor
Vertical specimen stroke: 70 mm
Sectioning modes: 4
Specimen retraction:
In manual operation: 5 – 100 µm in 5 µm increments, can be turned off
In motorized operation: varying with the sectioning speed, can be turned of
Electric coarse feed: 300 µm/s and 800 µm/s
Sectioning speed: 0.5 – 420 mm/s ± 10%
Maximum specimen size (L x H x W): 50 x 60 x 40 mm
Specimen orientation horizontal: ±8°, vertical: ±8°
Nominal supply voltages: 100/120/230/240 V AC ± 10%
Nominal frequency: 50/60 Hz
Power draw: 340 VA
Dimensions basic instrument
Width (incl. handwheel): 413 mm
Depth (incl. waste tray): 618 mm
Height (with storage area on cover): 305 mm
Weight (without accessories): Approx. 40 kg
Dimensions control panel: W x D x H 121 x 166 x 50 mm
Weight: approx. 0.66 kg, approx. 1.45 Ibs
Click Here To Download Catalogue | Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Features:
- Observation mode: Brightfield.
- Head: Trinocular, 360° rotating and 30° inclined. Interpupillary distance 48-75mm.
- Dioptric adjustement: On the left eyepiece tube.
- Eyepieces: WF10x/20 mm, high eye-point and secured by a screw.
- Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
- Objectives:
Equipped with binocular head and following objectives:
IOS N-PLAN 10x/0.25 (Cover/No Cover), with anti-fungus treatment
IOS N-PLAN 20x/0.40 (Cover/No Cover), with anti-fungus treatment
IOS N-PLAN 40x/0.65 (Cover/No Cover), with anti-fungus treatment
IOS W-PLAN MET 50x/0.75 (No Cover), with anti-fungus treatment
- Specimen stage: Double layer rackless mechanical sliding stage, 150×139 mm, 75×33 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
- Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
- Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
- Brightfield Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300 K) and light intensity control. Multi-plug 100-240Vac/6Vdc external power supply.
- Fluorescence Illumination: Extra efficiency LED, with light intensity control. Peak wavelength: 465 nm, Power: 3.6W.
- Epi Fluorescence Attachment: Slider with 3 positions (2 fluorescence, 1 brightfield), with 1 included filterset: Fluorescence B: EX 460-490, DM 505, EM 515LP: Acridine Yellow, Acridine Orange, Auramine, DiO, DTAF, FITC, GFP, YFP, etc.
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Phase contrast (Positive type) |
As optional |
|
Darkfield |
As optional |
|
Simple polarized light |
As optional |
Observation Method -
Incident Light |
Fluorescence |
Yes |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Trinocular (Siedentopf) |
|
Split ratio |
50/50 |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
20 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
21 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
Nosepiece |
Positions |
Quadruple |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
∞ |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-400x |
|
Type |
IOS |
|
Objectives included |
OS N-PLAN
10x/0.25, W.D. 5.8 mm
IOS N-PLAN
20x/0.40, W.D. 5.1 mm
IOS N-PLAN
40x/0.65, W.D. 0.43 mm
IOS W-PLAN MET
50x/0.75, W.D. 0.32 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
150x139 |
|
Moving mechanism |
Rackless |
|
Moving range (mm) |
75x33 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Abbe |
|
Removable |
Yes |
|
Numerical aperture (N.A.) |
1.25 |
|
Magnification scale for simplified positioning |
Yes |
|
Diaphragms |
Iris |
|
Centrable |
Yes |
|
Focusable |
By rack and pinion |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
18 |
|
Fine total travel (per single rotation) (mm) |
0.4 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
4 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
Transmitted
Illumination |
Kohler illumination |
Fixed |
|
Type |
X-LED |
|
X-LED type |
X-LED3 |
|
Light source power (W) |
3.6 |
|
Brightness control |
Manual |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
Mirror for transmitted light (as optional).
External rechargeable battery pack (as optional) |
Product Weight |
Height (mm) |
515 |
|
Width (mm) |
235 |
|
Depth (mm) |
340 |
Product Weight |
(kg) |
7.5 |
Fluorescence
Attachment |
Number of positions |
3 |
|
Blue filter set (included) specs |
Excitation: 460 - 490 nm; Dichroic: 505 nm;
Emission: 515LP nm |
|
Filter dimensions |
Excitation: 18 mm diam.;
Dichroic: 26.5 mm x 19 mm;
Emission: 18 mm diam. |
|
Filter set selection |
Manual |
Fluorescence Light
Source |
Light source |
Blue LED |
|
Watt (W) |
3.6 |
|
LED wavelength |
Blue LED: 465 nm |
|
Lifetime (hours) |
> 65,000 |
|
Brightness control |
Yes |
|
Reviews