Keewell QW-618 Blood & Infusion Warmer
$803.00
Shipped From Abroad
Clinical Application:
*Blood transfusion / infusion for the patients during operation or after operation
*Massive blood transfusion/infusion for emergency care and routine blood transfusion infusion in the clinical setting
*Intravenous nutrition or nasal feeding
*Children and neonates’ infusion
*Normal infusion in cold seasons
*Heating of the liquid for flushing
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features:
Clinical Application:
*Blood transfusion / infusion for the patients during operation or after operation
*Massive blood transfusion/infusion for emergency care and routine blood transfusion infusion in the clinical setting
*Intravenous nutrition or nasal feeding
*Children and neonates’ infusion
*Normal infusion in cold seasons
*Heating of the liquid for flushing
Technology of Control:
Microcomputer system provides high precise control , permanently running self-tests, and malfunction alarm
Temperature monitoring:
Numerical display for real-time temperature or setting temperature
Accuracy: ±0.5 ℃
Temperature setting: 37 ℃ ~ 40 ℃ ( adjustable at rate of 0.1 ℃)
High temperature cut-off: 41℃/45℃/48±3℃
Low temperature alarm: 36 ℃
Normal transfusion / infusion tubing can be used in low flow rate.
TECHNICAL SPECIFICATIONS:
Power supply: AC 220V±10% 50Hz±1Hz / 110V±10% 60Hz±1Hz
Power consumption: Max.250VA
Type of protection against electric shock: Class I
Degree of protection against electric shock: B
Waterproof and dustproof class: lp64
Warming time:<2min
Operating mode: Continuous working
Dimensions: 100×170×210mm
Net Weight: 1.3kg
Click Here To Download Catalogue
Quick Comparison
Settings | Keewell QW-618 Blood & Infusion Warmer remove | Keewell FT-1800 Blood & Infusion Warmer remove | Manual Suction Machine (Pedal) remove | Agary I.V. Cannula remove | DrGem Floor Mounted Analogue X-ray remove | Keewell FT-2800 Blood & Infusion Warmer remove | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Keewell QW-618 Blood & Infusion Warmer remove | Keewell FT-1800 Blood & Infusion Warmer remove | Manual Suction Machine (Pedal) remove | Agary I.V. Cannula remove | DrGem Floor Mounted Analogue X-ray remove | Keewell FT-2800 Blood & Infusion Warmer remove | ||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||
SKU | SF1033560077 | SF1033560076 | SF1033560084-171 | SF1033560084-221 | SF1033560074-6 | SF1033560075 | ||||||||
Rating | ||||||||||||||
Price | $803.00 | $781.00 | $40.00 | $7.10 |
| $781.00 | ||||||||
Stock | ||||||||||||||
Availability | ||||||||||||||
Add to cart | ||||||||||||||
Description | Shipped From Abroad
Clinical Application:
*Blood transfusion / infusion for the patients during operation or after operation
*Massive blood transfusion/infusion for emergency care and routine blood transfusion infusion in the clinical setting
*Intravenous nutrition or nasal feeding
*Children and neonates’ infusion
*Normal infusion in cold seasons
*Heating of the liquid for flushing
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Safety system:Permanent running self-tests, 24 hours continuous operating Double independent over-heating protections and automatic cut off Visual and acoustic alarm for high temperature / low temperature/sensor faultAdvance Dry Heating Technology:Quick Warming up and effective heatingHeating up to the patient:IV tube is completely wrapped in, no heat lossUser friendly interface:Big LED screen showing set temp., actual temp., heating time and fault situation | In stock
| In stock
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
| In Stock GXR Analogue X-ray system matches with a radiographic room which perfectly fits your workow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Technology of control:
Microprocessor integrated with temperature sensors provides high precise control
Safety system:
Permanent running self-tests, 24 hours continuous operating
Double independent over-heating protections and automatic cut off
Visual and acoustic alarm for high temperature / low temperature/sensor fault
Dual channels:
Each channel can work independently with own temp. setting and temp control
Two channels can be combined to enlarge the warming capacity
Heating up to the patient: IV tube is completely wrapped in, no heat loss
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||
Content | Features:
Clinical Application:
*Blood transfusion / infusion for the patients during operation or after operation
*Massive blood transfusion/infusion for emergency care and routine blood transfusion infusion in the clinical setting
*Intravenous nutrition or nasal feeding
*Children and neonates’ infusion
*Normal infusion in cold seasons
*Heating of the liquid for flushing
Technology of Control:
Microcomputer system provides high precise control , permanently running self-tests, and malfunction alarm
Temperature monitoring:
Numerical display for real-time temperature or setting temperature
Accuracy: ±0.5 ℃
Temperature setting: 37 ℃ ~ 40 ℃ ( adjustable at rate of 0.1 ℃)
High temperature cut-off: 41℃/45℃/48±3℃
Low temperature alarm: 36 ℃ Normal transfusion / infusion tubing can be used in low flow rate. TECHNICAL SPECIFICATIONS: Power supply: AC 220V±10% 50Hz±1Hz / 110V±10% 60Hz±1Hz Power consumption: Max.250VA Type of protection against electric shock: Class I Degree of protection against electric shock: B Waterproof and dustproof class: lp64 Warming time:<2minOperating mode: Continuous working Dimensions: 100×170×210mm Net Weight: 1.3kgClick Here To Download Catalogue | Features:Safety system:Permanent running self-tests, 24 hours continuous operating Double independent over-heating protections and automatic cut off Visual and acoustic alarm for high temperature / low temperature/sensor faultAdvance Dry Heating Technology:Quick Warming up and effective heatingHeating up to the patient:IV tube is completely wrapped in, no heat lossUser friendly interface:Big LED screen showing set temp., actual temp., heating time and fault situation Easy and quick to set up, ready to use within minutes.Open system:Accepts standard IV tube, no special disposables needed The most economical warming solution without extra consumable costs TECHNICAL SPECIFICATIONS Model: FT1800 Temperature setting: 33˚C - 41˚C Power supply: a.c.100~240V/50~60Hz Power consumption: Max. 120VA Type of protection against electric shock: Class I Degree of protection against electric shock: BF Applied part; Defibrillation-protected Degree of protection against ingress of liquids: IPX2 Temperature accuracy: ±1.0˚C Overheat protection: 42˚C/43˚C Low temperature alarm 32˚C Warming up time: From 20˚C to 36˚C approx. 2 min. Operating mode: Continuous Dimension (W*D*H): 85×65×175mm Net Weight: 1.2kg Warming profile: - length 1400mm - compatible IV tube 3.5-5.0mm O.D.Click Here To Download Catalogue | Pedal Suction offered by us is primarily used in hospitals of all levels for suction of phlegm, blood and other thick liquid during surgical operations and induced abortions. Due to its compact size, lightweight and trouble-free operation and it particularly fits for being extensively used in rural clinics, no power area, homes, remote areas, and other emergency occasions.
Features:
| I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size. | DrGem GXR Floor Mounted Analogue X-ray system matches with a radiographic room which perfectly fits your workflow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR (Analogue X-ray)system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR (Analogue X-ray) system is designed to provide convenience to operator and comfort to patient.
Features of DrGem GXR Floor Mounted Analogue X-ray:
Click Here To Download Catalogue | Features:Technology of control: Microprocessor integrated with temperature sensors provides high precise controlSafety system:Permanent running self-tests, 24 hours continuous operating Double independent over-heating protections and automatic cut off Visual and acoustic alarm for high temperature / low temperature/sensor faultDual channels:Each channel can work independently with own temp. setting and temp control Two channels can be combined to enlarge the warming capacity Heating up to the patient: IV tube is completely wrapped in, no heat lossUser friendly interface:Big LED screen showing set temp., actual temp., heating time and fault situation Easy and quick to set up, ready to use within minutes. Open system: Accepts standard IV tube, no special disposables needed The most economical warming solution without extra consumable costs TECHNICAL SPECIFICATIONS Model: FT2800 Temperature setting: 33 - 41˚C Power supply: a.c.100~240V/50~60Hz Power consumption: Max. 180VA Type of protection against electric shock: Class I Degree of protection against electric shock: BF Applied part; Defibrillation-protected Degree of protection against ingress of liquids: IPX2 Temperature accuracy: ±1.0˚C Overheat protection: 42˚C /43˚C Low temperature alarm: 32˚C Warming up time: From 20˚C to 36˚C approx.2 min. Operating mode: Continuous Dimension (W*D*H): 200×130×250mm Net Weight: 2.3kg Warming profile: - length 1400mm - compatible IV tube 3.5-5.0mm O.D.Click Here To Download Catalogue | ||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||
Additional information |
Reviews
There are no reviews yet.