New

LT-YJ2000-Liquid-Based Cytology Smear Processor

$0.00

Shipped From Abroad

The LT‑YJ2000 is a liquid‑based cytology smear processor designed for rapid preparation of thin‑layer, uniformly distributed cell specimens from diverse body fluids and exfoliative cytology, enabling efficient screening for cytological diagnosis in pathology and gynecology labs.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Lituo

Description

The LT‑YJ2000 Liquid‑Based Cytology Smear Processor utilises advanced membrane filtration and suction techniques to prepare monolayer smears from cervical, urinary, pleural, sputum, and other fluid specimens. With a streamlined workflow, it reduces manual preparation time and improves consistency across slides. The system supports multiple working modes to adapt to specimen types and ensures high‑quality diagnostic material with reduced debris and improved cell clarity. Ideal for pathology departments, women’s health clinics, and cytology labs focused on high throughput and reliability.

Features

Patented Technology: The First company in the country to use patented technology to automatically push and unload the membrane tube. The membrane tube can be automatically discharged into the collection cup, effectively avoiding secondary pollution.

Convenient: The operation is simple, and the operation steps are automated. The smear time of each specimen is no more than 2.5 minutes. The same specimen can be used to make slides repeatedly.

Informational: Scientific, market-tested software reporting system, convenient for printing, storing, and querying case reports.

Intelligent: Adopt high-definition, large-screen liquid display, synchronous operation display, and real-time monitoring. Adopt a pressure controller to effectively control system pressure, which can not only prevent membrane bursting but also collect diagnostic cells effectively.

 

Applications

Gynecology series: Cervical exfoliated cell examination. The cervix is easy to be exposed, observed, palpated, and to collect materials can be collected. It is effective to collect cervical diseased cells. Early examination is helpful for finding cervical diseased cells in time to prevent cervical cancer.

Non-gynecology series: Pleural and ascites cell examination. Clinical cases with pleural effusion and ascites are common. Collect enough pleural and ascites exfoliated cells, and prepare high-quality cell smears through membrane filtration and gradient centrifugation techniques to improve the defects of traditional cell smears and significantly increase the detection rate of positive cells for early detection of cancer.

Sputum cell examination: Exfoliated sputum cell examination is an important method for the diagnosis of lung cancer, especially for the early diagnosis of lung cancer. Effectively decomposing sputum and mucus and collecting sufficient sputum cells play an extremely important role in the screening of early lung cancer.

Urine cell examination: Nowadays, bladder cancer is the most harmful to men’s health. In the early stage, bladder cancer is usually asymptomatic, and intermittent painless gross hematuria does not appear until the late stage. It can detect early prostate cancer and bladder cancer in men, so that patients can be detected and treated early.
Technical Specifications
Specification Details
Model LT‑YJ2000
Input Voltage AC 220 V, 50 Hz
Input Power Approx. 300 W
Environment Ambient temperature: 15 °C – 30 °C; Relative humidity: 40% – 85%
Dimensions ~ 480 mm (L) × 460 mm (D) × 410 mm (H)
Net Weight Less than 35 kg
Processing Time Less than 3 minutes per slide
Specimen Types Cervical, body fluids (pleural, urine, etc), sputum, etc.
Application Area Cytology slide preparation for pathological/gynecological diagnosis

Reviews

There are no reviews yet.

Be the first to review “LT-YJ2000-Liquid-Based Cytology Smear Processor”

Your email address will not be published. Required fields are marked *

Quick Comparison

LT-YJ2000-Liquid-Based Cytology Smear Processor removeEppendorf Pipette Tip 200ul Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeZenithlab (IB-9025A) Laboratory Incubator removeAlcohol Pad Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameLT-YJ2000-Liquid-Based Cytology Smear Processor removeEppendorf Pipette Tip 200ul Per Pack removeSkyla Hi POC Clinical Chemistry Analyzer removeZenithlab (IB-9025A) Laboratory Incubator removeAlcohol Pad Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
ImageEppendorf Pipette Tip 200ul Per Pack
SKUSF1033560084-137SF1033560060-2SF1033560084-109SF1033560084-64SF1033560060-1
Rating
Price

$0.00

$0.00

$0.00

$350.00

$4.25

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The LT‑YJ2000 is a liquid‑based cytology smear processor designed for rapid preparation of thin‑layer, uniformly distributed cell specimens from diverse body fluids and exfoliative cytology, enabling efficient screening for cytological diagnosis in pathology and gynecology labs.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

The LT‑YJ2000 Liquid‑Based Cytology Smear Processor utilises advanced membrane filtration and suction techniques to prepare monolayer smears from cervical, urinary, pleural, sputum, and other fluid specimens. With a streamlined workflow, it reduces manual preparation time and improves consistency across slides. The system supports multiple working modes to adapt to specimen types and ensures high‑quality diagnostic material with reduced debris and improved cell clarity. Ideal for pathology departments, women’s health clinics, and cytology labs focused on high throughput and reliability.

Features
Patented Technology: The First company in the country to use patented technology to automatically push and unload the membrane tube. The membrane tube can be automatically discharged into the collection cup, effectively avoiding secondary pollution. Convenient: The operation is simple, and the operation steps are automated. The smear time of each specimen is no more than 2.5 minutes. The same specimen can be used to make slides repeatedly. Informational: Scientific, market-tested software reporting system, convenient for printing, storing, and querying case reports. Intelligent: Adopt high-definition, large-screen liquid display, synchronous operation display, and real-time monitoring. Adopt a pressure controller to effectively control system pressure, which can not only prevent membrane bursting but also collect diagnostic cells effectively.
 
Applications
Gynecology series: Cervical exfoliated cell examination. The cervix is easy to be exposed, observed, palpated, and to collect materials can be collected. It is effective to collect cervical diseased cells. Early examination is helpful for finding cervical diseased cells in time to prevent cervical cancer. Non-gynecology series: Pleural and ascites cell examination. Clinical cases with pleural effusion and ascites are common. Collect enough pleural and ascites exfoliated cells, and prepare high-quality cell smears through membrane filtration and gradient centrifugation techniques to improve the defects of traditional cell smears and significantly increase the detection rate of positive cells for early detection of cancer. Sputum cell examination: Exfoliated sputum cell examination is an important method for the diagnosis of lung cancer, especially for the early diagnosis of lung cancer. Effectively decomposing sputum and mucus and collecting sufficient sputum cells play an extremely important role in the screening of early lung cancer.
Urine cell examination: Nowadays, bladder cancer is the most harmful to men's health. In the early stage, bladder cancer is usually asymptomatic, and intermittent painless gross hematuria does not appear until the late stage. It can detect early prostate cancer and bladder cancer in men, so that patients can be detected and treated early.
Technical Specifications
Specification Details
Model LT‑YJ2000
Input Voltage AC 220 V, 50 Hz
Input Power Approx. 300 W
Environment Ambient temperature: 15 °C – 30 °C; Relative humidity: 40% – 85%
Dimensions ~ 480 mm (L) × 460 mm (D) × 410 mm (H)
Net Weight Less than 35 kg
Processing Time Less than 3 minutes per slide
Specimen Types Cervical, body fluids (pleural, urine, etc), sputum, etc.
Application Area Cytology slide preparation for pathological/gynecological diagnosis
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare