LT-YJ2000-Liquid-Based Cytology Smear Processor
$0.00
Shipped From Abroad
The LT‑YJ2000 is a liquid‑based cytology smear processor designed for rapid preparation of thin‑layer, uniformly distributed cell specimens from diverse body fluids and exfoliative cytology, enabling efficient screening for cytological diagnosis in pathology and gynecology labs.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The LT‑YJ2000 Liquid‑Based Cytology Smear Processor utilises advanced membrane filtration and suction techniques to prepare monolayer smears from cervical, urinary, pleural, sputum, and other fluid specimens. With a streamlined workflow, it reduces manual preparation time and improves consistency across slides. The system supports multiple working modes to adapt to specimen types and ensures high‑quality diagnostic material with reduced debris and improved cell clarity. Ideal for pathology departments, women’s health clinics, and cytology labs focused on high throughput and reliability.
Features
Patented Technology: The First company in the country to use patented technology to automatically push and unload the membrane tube. The membrane tube can be automatically discharged into the collection cup, effectively avoiding secondary pollution.
Convenient: The operation is simple, and the operation steps are automated. The smear time of each specimen is no more than 2.5 minutes. The same specimen can be used to make slides repeatedly.
Informational: Scientific, market-tested software reporting system, convenient for printing, storing, and querying case reports.
Intelligent: Adopt high-definition, large-screen liquid display, synchronous operation display, and real-time monitoring. Adopt a pressure controller to effectively control system pressure, which can not only prevent membrane bursting but also collect diagnostic cells effectively.
Applications
Gynecology series: Cervical exfoliated cell examination. The cervix is easy to be exposed, observed, palpated, and to collect materials can be collected. It is effective to collect cervical diseased cells. Early examination is helpful for finding cervical diseased cells in time to prevent cervical cancer.
Non-gynecology series: Pleural and ascites cell examination. Clinical cases with pleural effusion and ascites are common. Collect enough pleural and ascites exfoliated cells, and prepare high-quality cell smears through membrane filtration and gradient centrifugation techniques to improve the defects of traditional cell smears and significantly increase the detection rate of positive cells for early detection of cancer.
Sputum cell examination: Exfoliated sputum cell examination is an important method for the diagnosis of lung cancer, especially for the early diagnosis of lung cancer. Effectively decomposing sputum and mucus and collecting sufficient sputum cells play an extremely important role in the screening of early lung cancer.
Technical Specifications
| Specification | Details |
|---|---|
| Model | LT‑YJ2000 |
| Input Voltage | AC 220 V, 50 Hz |
| Input Power | Approx. 300 W |
| Environment | Ambient temperature: 15 °C – 30 °C; Relative humidity: 40% – 85% |
| Dimensions | ~ 480 mm (L) × 460 mm (D) × 410 mm (H) |
| Net Weight | Less than 35 kg |
| Processing Time | Less than 3 minutes per slide |
| Specimen Types | Cervical, body fluids (pleural, urine, etc), sputum, etc. |
| Application Area | Cytology slide preparation for pathological/gynecological diagnosis |
Quick Comparison
| LT-YJ2000-Liquid-Based Cytology Smear Processor remove | Automatic Pipette remove | Motic BA210 Series Biomedical Microscope remove | Hawksley 1400 Haematocrit Centrifuge remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | |||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | LT-YJ2000-Liquid-Based Cytology Smear Processor remove | Automatic Pipette remove | Motic BA210 Series Biomedical Microscope remove | Hawksley 1400 Haematocrit Centrifuge remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | ||||||||||||||||||||||||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||
| SKU | SF1033560084-130 | SF1033560084-78 | SF1033560084-118 | SF1033560084-125 | SF1033560084-30 | |||||||||||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Price |
|
|
| $690.00 | $1,320.00 | $9.50 | ||||||||||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
The LT‑YJ2000 is a liquid‑based cytology smear processor designed for rapid preparation of thin‑layer, uniformly distributed cell specimens from diverse body fluids and exfoliative cytology, enabling efficient screening for cytological diagnosis in pathology and gynecology labs.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped From Abroad
| In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||
| Content | The LT‑YJ2000 Liquid‑Based Cytology Smear Processor utilises advanced membrane filtration and suction techniques to prepare monolayer smears from cervical, urinary, pleural, sputum, and other fluid specimens. With a streamlined workflow, it reduces manual preparation time and improves consistency across slides. The system supports multiple working modes to adapt to specimen types and ensures high‑quality diagnostic material with reduced debris and improved cell clarity. Ideal for pathology departments, women’s health clinics, and cytology labs focused on high throughput and reliability. Features
Patented Technology: The First company in the country to use patented technology to automatically push and unload the membrane tube. The membrane tube can be automatically discharged into the collection cup, effectively avoiding secondary pollution.
Convenient: The operation is simple, and the operation steps are automated. The smear time of each specimen is no more than 2.5 minutes. The same specimen can be used to make slides repeatedly.
Informational: Scientific, market-tested software reporting system, convenient for printing, storing, and querying case reports.
Intelligent: Adopt high-definition, large-screen liquid display, synchronous operation display, and real-time monitoring. Adopt a pressure controller to effectively control system pressure, which can not only prevent membrane bursting but also collect diagnostic cells effectively.
Applications
Gynecology series: Cervical exfoliated cell examination. The cervix is easy to be exposed, observed, palpated, and to collect materials can be collected. It is effective to collect cervical diseased cells. Early examination is helpful for finding cervical diseased cells in time to prevent cervical cancer.
Non-gynecology series: Pleural and ascites cell examination. Clinical cases with pleural effusion and ascites are common. Collect enough pleural and ascites exfoliated cells, and prepare high-quality cell smears through membrane filtration and gradient centrifugation techniques to improve the defects of traditional cell smears and significantly increase the detection rate of positive cells for early detection of cancer.
Sputum cell examination: Exfoliated sputum cell examination is an important method for the diagnosis of lung cancer, especially for the early diagnosis of lung cancer. Effectively decomposing sputum and mucus and collecting sufficient sputum cells play an extremely important role in the screening of early lung cancer.
Urine cell examination: Nowadays, bladder cancer is the most harmful to men's health. In the early stage, bladder cancer is usually asymptomatic, and intermittent painless gross hematuria does not appear until the late stage. It can detect early prostate cancer and bladder cancer in men, so that patients can be detected and treated early.
Technical Specifications
| This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
| The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit | The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | Twenty Five (25) Test Strip per Pack | ||||||||||||||||||||||||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||
| Additional information |







Reviews
There are no reviews yet.