Features of Mainstream Anesthesia Multi-gas Sensor AG200
  • GAS ID identifies manually (CO2, N2O, ISO, DES, ENF, HAL, SEV).
  • Fully compatible with PHASEIN protocol.
  • Fast warm-up time display waveform within 15s.
  • Barometer pressure and temperature compensation.
  • Real-time and continuous measurement of gas concentrations and respiratory rate.
  • Low power consumption

 

Specifications of Mainstream Anesthesia Multi-gas Sensor AG200
Principle NDIR
Gas Identity By Manual
Initialization Time 15 sec, full specifications within 60 sec.
Calibration No routine user calibration required
Compensation Automatic for atmospheric pressure, temperature
Rise Time Co2 < 200ms, N2O,AA < 350ms
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Breath Detect Adaptive threshold, minimum 1% Co2 change
Agent Threshold Agent 0.3 vol%
Measuring Accuracy gas type range accuracy
CO2 0 – 10% ± (0.2 vol% +2% of reading)
10 -15% ± (0.3 vol% +2% of reading)
N2O 0 – 100% ± (2 vol% +2% of reading)
ISO, ENF, HAL 0 – 6% ± (0.2vol% +2% of reading)
DES 0 – 18% ± (0.2vol% +2% of reading)
SEV 0 – 8% ± (0.2vol% +2% of reading)
Voltage & Power 5.0VDC ±5%, Consumption Less than 1.5W
Interface RS232, operating at 9600bps
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing

Quick Comparison

SettingsMainstream Anesthesia Multi-gas Sensor AG200 removeKIT FOR THORACENTESIS & PARACENTESIS removeSpinal Epidural Pack removeAnesthetic Face Mask removeMediPlus Bain Circuit (Adult) removeTimesco Jumper Fingertip Pulse Oximeter remove
NameMainstream Anesthesia Multi-gas Sensor AG200 removeKIT FOR THORACENTESIS & PARACENTESIS removeSpinal Epidural Pack removeAnesthetic Face Mask removeMediPlus Bain Circuit (Adult) removeTimesco Jumper Fingertip Pulse Oximeter remove
ImageFingertip Pulse Oximeter
SKUSF1033560130101-5SF1033560084-25SF1033560084-141SF1033560084-21SF1033560084-2
Price

$0.00

$0.00

$0.00

$8.00

$28.00

$17.00

Add to cart
DescriptionShipped From Abroad

AG200 series anesthesia gas sensor is the ideal low sampling-rate anesthesia solution for your patient monitoring system. AG200 is more cost-effective compared to the AG100 Side stream AGM Sensor.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Mainstream Anesthesia Multi-gas Sensor AG200
  • GAS ID identifies manually (CO2, N2O, ISO, DES, ENF, HAL, SEV).
  • Fully compatible with PHASEIN protocol.
  • Fast warm-up time display waveform within 15s.
  • Barometer pressure and temperature compensation.
  • Real-time and continuous measurement of gas concentrations and respiratory rate.
  • Low power consumption
 
Specifications of Mainstream Anesthesia Multi-gas Sensor AG200
Principle NDIR
Gas Identity By Manual
Initialization Time 15 sec, full specifications within 60 sec.
Calibration No routine user calibration required
Compensation Automatic for atmospheric pressure, temperature
Rise Time Co2 < 200ms, N2O,AA < 350ms
Respiration 3 – 150 BPM; Accuracy: ±1 BPM
Breath Detect Adaptive threshold, minimum 1% Co2 change
Agent Threshold Agent 0.3 vol%
Measuring Accuracy gas type range accuracy
CO2 0 – 10% ± (0.2 vol% +2% of reading)
10 -15% ± (0.3 vol% +2% of reading)
N2O 0 – 100% ± (2 vol% +2% of reading)
ISO, ENF, HAL 0 – 6% ± (0.2vol% +2% of reading)
DES 0 – 18% ± (0.2vol% +2% of reading)
SEV 0 – 8% ± (0.2vol% +2% of reading)
Voltage & Power 5.0VDC ±5%, Consumption Less than 1.5W
Interface RS232, operating at 9600bps
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing

KIT FOR THORACENTESIS & PARACENTESIS

The device is used to drain ascitic fluid and pleural liquid, it contains everything necessary for performing thoracentesis and paracentesis procedure (needles  syringe and collection bag). Products are customized upon request.  
Reference Description Qty per box
H92000E TORASET 1-55 30 pcs
H92010E TORASET 1-80 30 pcs
H92020E TORASET 1-VER 30 pcs
H92030E TORASET2-55 30 pcs
H92040E TORASET 2-80 30 pcs
H92050E TORASET 2-VER 30 pcs
H92001E TORAMATIC 1-55 30 pcs
H92011E TORAMATIC 1-80 30 pcs
H92021E TORAMATIC 1-VER 30 pcs
H92120E PARASET 2 30 pcs
H92160E PARASET 5 20 pcs
H92200E PARASET 8 20 pcs
H92240E PARASET 12 15 pcs
 
Click here to download Catalogue
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection. Features:
  • Soft cushion for patient comfort and air tight fit
  • Clear flexible housing and cushion for good patient visibility
  • Four sizes available, from small adultl to extra large adult
  • Each mask supplied with color-coded hook ring.
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A