Medical Waste Incinerator 100kg

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130107-2
Brands:: Shandong LVDU

Description

Characteristics

The main characteristics and scope of application of incinerator
LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world’s advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features:
1. Gasification incineration technology is applied to the incineration of syringes, drip containers and other medical equipment as well as all kinds of paper waste, bandages, absorbent cotton, all kinds of medical sewage and all kinds of waste discharged by hospitals and medical institutions.
2. Using gasification incineration method, the waste generated every day can be incinerated once.
3. The use of gasification incineration, mixed incineration, burnout treatment and other technologies, so that the exhaust smoke, soot content is lower than the national emission standards.
4. Fully enclosed operation, suitable for the treatment of infectious medical waste, to avoid secondary pollution.
5. Small size, small footprint.
6. The series of incinerators are divided into fuel oil and gas, and users can use different types according to their needs.
Technical characteristics of incinerators
LDF series medical waste incinerator adopts the most advanced incineration method of primary pyrolysis gasification + wind cocombustion + secondary incineration + burnout treatment. The design of the primary combustion chamber of the incinerator adopts the gasification incineration technology to make the temperature in the incinerator shift from 200ºC to 400ºC, and the waste will not produce frit, slag, sintering and other problems in the incineration process. Compared with direct combustion furnace and other furnaces, the dust production of gasification incinerator is very small, and secondary combustion burners and circumferential air supply devices are installed in the secondary mixed incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully burned, and the gas produced by the gasifier can be fully mixed with the air to burn efficiently, preventing the carbon in the gas flame from escaping and the occurrence of late burning. When the flue gas enters the high temperature burnout chamber, due to the use of tangential entry and tangential entry of combustion-supporting air, the flue gas can be fully burned again in the burnout chamber, and the use of rotating airflow for flue gas dust removal. The residence time of the incinerator flue gas in the furnace is greater than 2 seconds, so that the combustible gas in the flue gas and the combustible matter in the fly ash are completely incinerated. The upper part of the incinerator is equipped with dry tail gas purification equipment to adsorb hydrogen chloride and sulfur oxides produced in the incineration, and the odor and other components in the flue gas are decomposed at high temperature. The flue gas purification system is equipped with calcium hydroxide filter brick for neutralizing reaction with acid gas to achieve the purpose of adsorption of acid gas and purification of tail gas. The harmful components in the flue gas are reduced to the national “Hazardous Waste incineration Pollution Control Standard (GB18484-2001)” and other standards below the specified value.
The operation control of the incinerator adopts automatic program control, which reduces the labor degree of the workers, and the design of the furnace door and ash cleaning door adopts the fully sealed structure in the form of the child and the mother. During the incineration, the furnace is completely isolated from the outside of the furnace, forming negative pressure combustion, which eliminates the possibility of secondary pollution, especially the treatment of infectious dangerous medical waste, which can highlight its unique advantages.

Reviews

There are no reviews yet.

Be the first to review “Medical Waste Incinerator 100kg”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMedical Waste Incinerator 100kg removeMedical Waste Incinerator 60kg removeSharps Containers – PBS Series 5 LT removeManual Needle Destroyer – 0.8Ltr. Polycarbonate Body removeSharps Containers – PBS Series 0.8 LT removeSTERIPLUS 80 remove
NameMedical Waste Incinerator 100kg removeMedical Waste Incinerator 60kg removeSharps Containers – PBS Series 5 LT removeManual Needle Destroyer – 0.8Ltr. Polycarbonate Body removeSharps Containers – PBS Series 0.8 LT removeSTERIPLUS 80 remove
Image
SKUSF1033560130107-2SF1033560130107-1SF103356013097-3
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The PBS Series 5 Ltr Sharps Container is a high-capacity solution for safe disposal of syringes, needles, and other biohazard sharps. With a secure locking lid and puncture-proof body, it’s ideal for hospitals, diagnostic centers, and high-traffic healthcare facilities.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

This 0.8-litre manual needle destroyer features a tough polycarbonate body for long-lasting use. Designed for safe and hygienic disposal of used needles, it’s ideal for clinics, labs, and mobile healthcare settings, effectively reducing contamination risks and supporting safe biomedical waste practices.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The PBS Series 0.8 Ltr Sharps Container is a compact, high-quality solution for the safe disposal of used needles, syringes, and other sharps. Ideal for clinics, home care, and mobile medical units, it offers secure, puncture-proof containment with a reliable locking lid.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
INTEGRATED INFECTIOUS WASTE PRE-SHREDDING AND STEAM STERILIZATION SYSTEM
Tesalys STERIPLUS ™ systems are the ideal solution to safely inactivate your infectious waste on site. Their integrated TESASHRED ™ shredding system not only allows a consequent reduction in the volume and weight of waste, but also guarantees their treatment at heart.  
Click here to download Catalogue
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Characteristics
The main characteristics and scope of application of incinerator LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world's advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features: 1. Gasification incineration technology is applied to the incineration of syringes, drip containers and other medical equipment as well as all kinds of paper waste, bandages, absorbent cotton, all kinds of medical sewage and all kinds of waste discharged by hospitals and medical institutions. 2. Using gasification incineration method, the waste generated every day can be incinerated once. 3. The use of gasification incineration, mixed incineration, burnout treatment and other technologies, so that the exhaust smoke, soot content is lower than the national emission standards. 4. Fully enclosed operation, suitable for the treatment of infectious medical waste, to avoid secondary pollution. 5. Small size, small footprint. 6. The series of incinerators are divided into fuel oil and gas, and users can use different types according to their needs. Technical characteristics of incinerators LDF series medical waste incinerator adopts the most advanced incineration method of primary pyrolysis gasification + wind cocombustion + secondary incineration + burnout treatment. The design of the primary combustion chamber of the incinerator adopts the gasification incineration technology to make the temperature in the incinerator shift from 200ºC to 400ºC, and the waste will not produce frit, slag, sintering and other problems in the incineration process. Compared with direct combustion furnace and other furnaces, the dust production of gasification incinerator is very small, and secondary combustion burners and circumferential air supply devices are installed in the secondary mixed incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully burned, and the gas produced by the gasifier can be fully mixed with the air to burn efficiently, preventing the carbon in the gas flame from escaping and the occurrence of late burning. When the flue gas enters the high temperature burnout chamber, due to the use of tangential entry and tangential entry of combustion-supporting air, the flue gas can be fully burned again in the burnout chamber, and the use of rotating airflow for flue gas dust removal. The residence time of the incinerator flue gas in the furnace is greater than 2 seconds, so that the combustible gas in the flue gas and the combustible matter in the fly ash are completely incinerated. The upper part of the incinerator is equipped with dry tail gas purification equipment to adsorb hydrogen chloride and sulfur oxides produced in the incineration, and the odor and other components in the flue gas are decomposed at high temperature. The flue gas purification system is equipped with calcium hydroxide filter brick for neutralizing reaction with acid gas to achieve the purpose of adsorption of acid gas and purification of tail gas. The harmful components in the flue gas are reduced to the national "Hazardous Waste incineration Pollution Control Standard (GB18484-2001)" and other standards below the specified value. The operation control of the incinerator adopts automatic program control, which reduces the labor degree of the workers, and the design of the furnace door and ash cleaning door adopts the fully sealed structure in the form of the child and the mother. During the incineration, the furnace is completely isolated from the outside of the furnace, forming negative pressure combustion, which eliminates the possibility of secondary pollution, especially the treatment of infectious dangerous medical waste, which can highlight its unique advantages.
Characteristics
The main characteristics and scope of application of incinerator LDF series medical waste incinerator is a medical waste incineration equipment with independent intellectual property rights developed by Shandong Lvdu Environmental Equipment Co., LTD., which introduced the world's advanced medical incinerator technology and organized technical experts to tackle key problems. The equipment has the characteristics of full closure, small size, high incineration efficiency, reasonable process, leading technology, and high degree of harmfulness. It is an ideal garbage disposal equipment for all kinds of hospitals, hotels, stations, large commercial institutions, enterprises, and public institutions. Main features: 1. Gasification incineration technology is applied to the incineration of syringes, drip containers and other medical equipment as well as all kinds of paper waste, bandages, absorbent cotton, all kinds of medical sewage and all kinds of waste discharged by hospitals and medical institutions. 2. Using gasification incineration method, the waste generated every day can be incinerated once. 3. The use of gasification incineration, mixed incineration, burnout treatment and other technologies, so that the exhaust smoke, soot content is lower than the national emission standards. 4. Fully enclosed operation, suitable for the treatment of infectious medical waste, to avoid secondary pollution. 5. Small size, small footprint. 6. The series of incinerators are divided into fuel oil and gas, and users can use different types according to their needs. Technical characteristics of incinerators LDF series medical waste incinerator adopts the most advanced incineration method of primary pyrolysis gasification + wind cocombustion + secondary incineration + burnout treatment. The design of the primary combustion chamber of the incinerator adopts the gasification incineration technology to make the temperature in the incinerator shift from 200ºC to 400ºC, and the waste will not produce frit, slag, sintering and other problems in the incineration process. Compared with direct combustion furnace and other furnaces, the dust production of gasification incinerator is very small, and secondary combustion burners and circumferential air supply devices are installed in the secondary mixed incineration chamber. At high temperatures, the combustible gas in the flue gas can be fully burned, and the gas produced by the gasifier can be fully mixed with the air to burn efficiently, preventing the carbon in the gas flame from escaping and the occurrence of late burning. When the flue gas enters the high temperature burnout chamber, due to the use of tangential entry and tangential entry of combustion-supporting air, the flue gas can be fully burned again in the burnout chamber, and the use of rotating airflow for flue gas dust removal. The residence time of the incinerator flue gas in the furnace is greater than 2 seconds, so that the combustible gas in the flue gas and the combustible matter in the fly ash are completely incinerated. The upper part of the incinerator is equipped with dry tail gas purification equipment to adsorb hydrogen chloride and sulfur oxides produced in the incineration, and the odor and other components in the flue gas are decomposed at high temperature. The flue gas purification system is equipped with calcium hydroxide filter brick for neutralizing reaction with acid gas to achieve the purpose of adsorption of acid gas and purification of tail gas. The harmful components in the flue gas are reduced to the national "Hazardous Waste incineration Pollution Control Standard (GB18484-2001)" and other standards below the specified value. The operation control of the incinerator adopts automatic program control, which reduces the labor degree of the workers, and the design of the furnace door and ash cleaning door adopts the fully sealed structure in the form of the child and the mother. During the incineration, the furnace is completely isolated from the outside of the furnace, forming negative pressure combustion, which eliminates the possibility of secondary pollution, especially the treatment of infectious dangerous medical waste, which can highlight its unique advantages.
Features:
  • 5 Litre Capacity: Suitable for high-volume sharps waste in hospitals and labs.

  • High-Strength Polypropylene: Durable, leak-proof, and puncture-resistant.

  • Dual Locking Lid: Temporary and final lock ensures safe, tamper-proof disposal.

  • Wide Mouth Opening: Allows for easy and safe disposal of bulkier sharps.

  • Integrated Needle Remover: Enables safe removal without direct contact.

  • Color-Coded for Biohazard: Yellow/red with biohazard symbol for clear identification.

  • Stackable Design: Saves storage space and improves handling logistics.

  • One-Hand Use: Enables hygienic disposal without touching sharps.

Specifications:
Specification Details
Product Name Sharps Container – PBS Series 5 Ltr
Material Medical-Grade Polypropylene (PP)
Capacity 5 Litres
Lid Type Snap-fit with temporary & final lock
Puncture Resistant Yes
Leak-Proof Yes
Color Options Yellow or Red (Biohazard-labeled)
Dimensions Approx. 24–28 cm (H) × 20–22 cm (W)
Compliance WHO, CPCB, and biomedical waste guidelines
Labeling Biohazard symbol and disposal instructions
Features:
  • High-Quality Polycarbonate Body: Strong, transparent, and impact-resistant for long-term use.

  • 0.8-Litre Capacity: Suitable for low to moderate needle disposal volumes.

  • Manual Cutting Mechanism: Quick and easy needle destruction without electricity.

  • User-Safe Operation: Reduces risk of needle-stick injuries with enclosed blade design.

  • Compact & Portable: Lightweight and space-saving, perfect for small clinics or mobile setups.

  • Low Maintenance: Easy to clean with minimal mechanical parts.

  • Transparent Body: Allows for visual monitoring of waste levels.

Specifications:
Specification Details
Product Name Manual Needle Destroyer – 0.8 Ltr.
Body Material Polycarbonate (transparent, impact-resistant)
Capacity 0.8 Litres
Operation Type Manual (no power or battery required)
Cutting Function Needle cutting and destruction
Cutting Blade Material Stainless steel or hardened alloy (non-rusting)
Safety Features Enclosed cutting mechanism to prevent exposure
Color Transparent body (natural) with colored top (optional)
Portability Compact and lightweight
Lid Type Snap-fit or screw-on (varies by model)
Waste Storage Integrated sealed compartment for used needles
Dimensions Approx. 12–15 cm height × 10–12 cm diameter
Weight Around 200–300 grams
Reusable Yes, until full capacity is reached
Disposal Compliance Follows biomedical waste disposal standards
Features:
  • 0.8 Litre Capacity: Suitable for low to moderate sharps disposal needs.

  • Durable Polypropylene Material: Puncture-resistant and leak-proof for safety.

  • Temporary & Final Lock Lid: Prevents accidental opening and ensures permanent closure after use.

  • Needle Remover Slot: Integrated feature for hands-free needle removal.

  • Color-Coded Biohazard Design: Yellow/red color with biohazard marking for easy identification.

  • Portable & Stackable: Easy to carry, store, and transport.

  • One-Hand Operation: Enables safe disposal using only one hand.

Specifications:
Specification Details
Product Name Sharps Container – PBS Series 0.8 Ltr
Material Medical-Grade Polypropylene (PP)
Capacity 0.8 Litres
Lid Type Snap-on with temporary and permanent lock
Puncture Resistance Yes
Leak-Proof Yes
Color Options Yellow or Red (Biohazard-labeled)
Dimensions 13–15 cm (H) × 10–12 cm (W)
Compliance WHO, CPCB, and biomedical waste disposal norms
Labeling Printed with biohazard symbol and instructions
STERIPLUS  80
On-site infectious risk waste treatment solution
https://youtu.be/ahPvNNrzIMk?si=8dLL5Pn1YWY_sUM7
Features

Fully automated

The STERIPLUS™ 80 is an easy-to-use, on-site processing solution.

Large capacity

The loading chamber has a capacity of 80 litres, i.e. 1 TESABOX 80 or 2 TESABOX 40 or 4 TESABOX 20.

Fully integrated system

The STERIPLUS™ 80 is a fully automated solution for pre-grinding and steam sterilization of infectious wastes.  
Technical Data
 
LOADING CHAMBER CAPACITY 80 L
LOADING CHAMBER USEFUL DIMENSIONS (W x D x H) 370 x 360 x 628 mm
LOADING CAPACITY (containers) 1 X TESABOX 80 or 2 X TESABOX 40 or 4 X TESABOX 20
TOTAL CYCLE TIME (NF X30-503-1 standard) (1) 30 to 35 min
TOTAL CYCLE TIME in working conditions (2) 30 to 50 min.
LOADING CAPACITY (KG/CYCLE) 6,4 to 9,6 kg/cycle - Based on an average waste density of 0,08 to 0,12kg/L for HealthCare Waste 9,6 to 16 kg/cycle- Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid
TREATMENT CAPACITY (KG/H) (3) 8 to 12 kg/h - Based on an average waste density of 0,08 to 0,12kg/L for HealthCare Waste 12 to 20 kg/h - Based on an average waste density of 0,12 to 0,2kg/L for Lab/Humid/Liquid
MAX QUANTITY OF LIQUID RECOMMENDED PER CYCLE (4) 24 L
EXTERNAL DIMENSIONS (w x d x h) 1550 x 1200 x 1800 mm
NET WEIGHT 1300 kg
LOADING CHAMBER Stainless steel with PTFE coating
TREATMENT CHAMBER AISI 304L stainless steel
STEAM GENERATOR AISI 304L stainless steel (chamber) & Highly corrosion-resistant Hastelloy®
WATER SOFTENER Built-in
WATER BOOSTER PUMP AND AIR COMPRESSOR Built-in
WASTER SHREDDER Structure: AISI 304L stainless steel & Blades: High-strength steel
PIPING Stainless steel/PTFE flexible hosing
CHASSIS Painted steel
BODYWORK Composite material / Painted steel
CYCLE TRACEABILITY - THROUGH PRINTOUT Built-in
USB PORT Built-in
 
Utilities
WATER
Requirements Softened water (4-8°TH)
Consumption 15 liters / cycle
ELECTRICITY
Requirements 380-400 V III N, 50Hz/60Hz, 20 kW
Consumption 3 kWh/cycle
DRAIN ø 32 mm  internal (heat-resistant)
STEAM/COMPRESSED AIR Produced by the integrated steam generator and air compressor; no external connection required.
Accessories
           
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar