Motor Fuel Filtering Factor Tester UOVT-01
$0.00
Shipped From Abroad
Purpose:
Determination of the filtration coefficient according to GOST 19006-73
Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system.
Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73.
The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
Determination of the filtration coefficient according to GOST 19006-73
Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system.
Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73.
The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73.
Scope of delivery:
1. Graduated glass tube cut from a burette 1-2-50-0.1, according to GOST 20292-74 in a metal mount, and an extension made of Caprolon in its top – 1 pc.
2. Glass or metal cock in a mount of a filtering device – 1 pc.
3. Filter mount – 1 pc.
4. Filter seat – 1 pc.
5. Gasket 1x17x19 – 2 pcs.
6. Gasket 1x15x17 – 2 pcs.
7. Filter paper, BFDT brand, with the screening fineness not exceeding 3µm (0.33+/-0.03) mm thickness, the number of analyses – 50 pcs.
8. Volumetric flask 1-50-2, 50 cm3, according to GOST 1770-74 – 1 pc.
9. Beaker V or N, version 1 or 2, 400 or 600 cm? capacity, according to GOST 25336-82 (made of glass or polypropylene) – 1 pc.
10. Cylinder 1-50 or 3-50, according to GOST 1770-74 – 1 pc.
11. GOST 19006-73 – 1 pc.
12. Operating manual – 1 pc.
13. Storage case – 1 pc.
Review(1)
Quick Comparison
Settings | Motor Fuel Filtering Factor Tester UOVT-01 remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | 8 Bucket Centrifuge remove | Little Sister Table Top Autoclave remove | Erma B-111 Bilirubin Meter remove | Automatic Pipette remove | ||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Motor Fuel Filtering Factor Tester UOVT-01 remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | 8 Bucket Centrifuge remove | Little Sister Table Top Autoclave remove | Erma B-111 Bilirubin Meter remove | Automatic Pipette remove | ||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560103 | SF1033560060-1 | SF1033560084-114 | SF1033560084-46 | SF1033560084-6 | SF1033560084-130 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
| $72.50 | $1,350.00 | $715.00 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Purpose:
Determination of the filtration coefficient according to GOST 19006-73
Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system.
Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73.
The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Purpose: Determination of the filtration coefficient according to GOST 19006-73 Applied in organizations controlling quality of fuels and lubricants, in petroleum refining industry, in oil products distribution system. Shall be used to test the filtration coefficient of motor fuels according to GOST 19006-73. The device shall be assembled and the filtration coefficient shall be tested according to GOST 19006-73. Scope of delivery: 1. Graduated glass tube cut from a burette 1-2-50-0.1, according to GOST 20292-74 in a metal mount, and an extension made of Caprolon in its top – 1 pc. 2. Glass or metal cock in a mount of a filtering device – 1 pc. 3. Filter mount – 1 pc. 4. Filter seat – 1 pc. 5. Gasket 1x17x19 – 2 pcs. 6. Gasket 1x15x17 – 2 pcs. 7. Filter paper, BFDT brand, with the screening fineness not exceeding 3µm (0.33+/-0.03) mm thickness, the number of analyses – 50 pcs. 8. Volumetric flask 1-50-2, 50 cm3, according to GOST 1770-74 – 1 pc. 9. Beaker V or N, version 1 or 2, 400 or 600 cm? capacity, according to GOST 25336-82 (made of glass or polypropylene) – 1 pc. 10. Cylinder 1-50 or 3-50, according to GOST 1770-74 – 1 pc. 11. GOST 19006-73 – 1 pc. 12. Operating manual – 1 pc. 13. Storage case – 1 pc. | Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue | 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods.
Features:
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
vorbelutr ioperbir
I do not even know how I ended up right here, but I assumed this submit was once great. I don’t recognize who you might be however definitely you’re going to a famous blogger when you are not already 😉 Cheers!